Fabricant : Cornelius
Taille : 67.03 kb
Nom Fichier :
|
Facilité d'utilisation
COMP” terminal on the Control Board. 11. Connect other end of the black electrical wire, connected to “LIVE OUT” terminal on the Voltage Protector Module, to compressor black electrical wire disconnected from the control board “SW. COMP” terminal in preceding step 10. 12. Connect one end of the blue ELECTRICAL WIRE (item 4) to “LIVE IN” terminal on the Voltage Protector Module. 13. Connect other end of the blue ELECTRICAL WIRE (item 4) to “SW. COMP” terminal on control board where compressor electrical wire was disconnected from in step 10 preceding. 14. Connect one end of the brown ELECTRICAL WIRE (item 2) to “L2” terminal on the control board. This connection consist of two electrical wires connected to “L2” terminal with a piggy-back push on terminal. 15. Connect other end of the brown ELECTRICAL WIRE (item 2) to “NEUTRAL” terminal on the Voltage Protector Module. 16. Install control box cover and secure with two screws. 17. Connect electrical power to the Dispenser. Check Dispenser for proper operation. When refrigeration compressor isoperating, green light on the Voltage Protector Module will be illuminated. When refrigeration compressor is not operating, the yellow light on the Voltage Protector Module will be illuminated. 18. Install hood on Dispenser and secure with screw. 569000242 2 3 569000242 -OPTIONAL CAPACITOR QP GREEN INDICATOR LIGHT YELLOW INDICATOR LIGHT WHITE OR BLUE PIGGY BACK TERMINAL CONNECTION SW I TCH 'DOMESTIC UNITS ONLY) BLACK OR BROWN BROWN INTEGRAL CARBONATOR UNITS ONLY ORANGE INTEGRAL CARBONATOR UNITS ONLY VALVES FIGURE 2. WIRING DIAGRAM...
Ce manuel est également adapté pour les modèles :Dispensers - 230 VAC (67.03 kb)