the pilot flame 2. Loose spark wire; loose igniter nut. 3. Piezo-electric igniter does not generate a spark. 2. Check spark wire connection at the igniter nut and make sure the connection is tight. 3. Replace igniter mechanism (portion with pushbutton). Pilot flame does not stay lighted. 1. Dirty/sooty pilot burner. 2. Low gas supply pressure [less than 6” W.C. for natural gas; (11” W.C. for propane) when all other gas-powered equipment is operating]. 3. Pilot flame too small to heat the thermoc
This easy to store mobile filter unit removes crumbs and sediment that cause flavor transfer and faster shortening breakdown. The compact system is simple to disassemble using quick disconnects making it very easy to clean. Changing filter envelopes is a snap with the unique and simple Anets design. Serve a great tasting product and save money and time with the Anets Portable Filter System. STANDARD FEATURES ■ New Anets filter screen eliminates clogging utilizing a special envelope style filte
Turn the thermostat until it ‘clicks’ off (causing the main burners to go out); note the setting where this occurs. Repeat this temperature ‘click points’ step at least three times to ensure that the shortening temperature has stabilized. Measure the temperature of the shortening by inserting an accurate thermometer about 4 inches into the shortening to measure its temperature. If the temperature variation between the measured temperature and the thermostat setting is 10°F or less, the thermosta
DO NOT use a flame to check for leaks. 1. Ensure that the gas control valve knob in the 5. Open the gas supply line valve (handle in-line fryer has its OFF position next to the valve with line direction); then, confirm that all gas mark. supply line joints and couplings are free of leaks using soap suds or a leak-check solu 2. Ensure that the gas supply inlet line valve is tion, after the fryer is in its desired location. closed (handle crosswise to the line direction). 6. Plug the fryer’s elect
electric fryer design provides high efficiency, quick recovery and short preheating time! Tubular type heating elements produce efficient energy transfer for fast frying and quick recovery to produce maximum cooking output of the fryer. Increase your frying capacity per hour with the new Anets SLE40 electric fryer. Simple to install, simple to operate, simple to clean. The SLE40 electric fryer has been engineered with high reliability and priced to purchase today. STANDARD FEATURES Stainless s
You may have to press down the control knob for as long as several minutes until the pilot flame burns steadily. 1. Switch the circuit breaker controlling electric power to the fryer to ON. 2. Ensure that the fryer’s thermostat knob is set to OFF. 3. Open the gas supply line inlet valve to the fryer by aligning the gas valve handle with the gas line piping. 4. Open the front door and move the right pilot viewing/lighting port cover aside. 5. Turn the gas control valve knob to align the PILOT set
Damage caused by melting solid shortening will NOT be covered by the warranty. ! FRYER PREPARATION FOR USE “BOIL OUT” INSTRUCTIONS Before using the newly installed fryer for food preparation, clean the rust preventive material from the kettle: 1. Thoroughly wipe the interior of the kettle with clean cloths. Open the front door on the lower portion of the fryer to access the drain ball valve. Open the drain ball valve (by aligning the valve handle with the drain ball valve) and wipe the entire dr
DO NOT cut or remove the grounding prong from this plug. CODE REQUIREMENTS CODE REQUIREMENTSCODE REQUIREMENTSCODE REQUIREMENTSCODE REQUIREMENTSCODE REQUIREMENTS IMPORTANT: Read the Code Requirements and the Installation Requirements and Iinstructions carefully, before starting the installation. Contact the factory (800/ 837-2638) if any problems or questions arise. The fryer installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1
■ Foodservice Equipment That Turns Food Into Gold 180 North Anets Drive ■ Northbrook, Illinois 60062 1-800-837-2638 ■ Fax 847-272-1943 ■ Anets GoldenFiy™ Portable Filter System FFM80/FFM150 SPECIFICATIONS ■ Model ■ Certification ■ Electrical Requirements ■ Motor ■ Pump Speed ■ Shortening Capacity ■ Casters ■ Filter Tank ■ Approx. Shipping wt. FFM80 FFM150 NSF, UL, CUL 120 V, 1 Phase, 8 Amps 6' cord and plug included 1/3 HP 5 Gallons per minute FFM80 - 80 lbs. FFM150 - 150 lbs
Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. ! FOR YOUR SAFETY DO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. ! WARNING After installation of this equipment, immediately contact your local gas supplier to obtain information about what action to take whenever any person smells gas. Post this information in a prominent location. Keep this Manual in a Conveni