For professional use only. Not for use in explosive atmospheres. 100 psi (0.7 MPa, 7 bar) Maximum Fluid Working Pressure 100 psi (0.7 MPa, 7 bar) Maximum Air Inlet Pressure Model 224892, Series A aluminum, with PTFE diaphragm Model 224893, Series A aluminum, with buna–N diaphragm Model 224894, Series B stainless steel, with PTFE diaphragm Model 224895, Series B stainless steel, with buna–N diaphragm Table of Contents Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operation and Maintenance . . . . . . . . . . . . . . . . . . . 7 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Parts Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Parts Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Repair Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Dimensional Drawing . . . . . . . . . . . . . . . . . . . . . . . 15 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Graco Phone Number . . . . . . . . . . . . . . . . . . . . . . . 20 WARNING Hazard of Using Fluids Containing Halogenated Hydrocarbons Never use 1.1.1–trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents in aluminum models 224892 or 224893. Such use could result in a chemical reaction, with the possibility of explosion, which could cause death, serious bodily injury, and/or substantial property damage. Consult your fluid suppliers to ensure that the fluids being used are compatible with aluminum and zinc parts. Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. 0903 AAAAAA Symbols Warning Symbol Caution Symbol WARNING CAUTION This symbol alerts you to the possibility of serious This symbol alerts you to the possibility of damage to injury or death if you do not follow the instructions. or destruction of equipment if you do not follow the instructions. WARNING EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury. INSTRUCTIONS . This equipment is for professional use only. . Read all instruction manuals, tags, and labels before operating the equipment. . Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor. . Do not alter or modify this equipment. Use only genuine Graco parts and accessories. . Check equipment daily. Repair or replace worn or damaged parts immediately. . Do not exceed the maximum working pressure of the lowest rated component in your system. See Technical Data on page 16. . Use fluids and solvents that are compatible with the equipment wetted parts. Refer to the Technical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings. . Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 82C (180F) or below –40C (–40F). . Wear hearing protection when operating this equipment. . Do not lift pressurized equipment. . Comply with all applicable local, state, and national fire, electrical, and safety regulations. . . WARNING TOXIC FLUID HAZARD Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed. . Know the specific hazards of the fluid you are using. . Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines. . Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and solvent manufacturer. . Graco does not manufacture or supply the reactive chemical components that may be used in this equipment and is not responsible for injury or property loss, damage, expense or claims (direct or consequential) that arise from the use of such chemical components. FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury. . Ground the equipment. See Grounding on page 4. . If there is any static sparking or you feel an electric shock while using this equipment, stop pumping immediately. Do not use the equipment until you identify and correct the problem. . Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being pumped. . Keep the work area free of debris, including solvent, rags, and gasoline. . Electrically disconnect all equipment in the work area. . Extinguish all open flames or pilot lights in the work area. . Do not smoke in the work area. . Do not turn on or off any light switch in the work area whil...

Ce manuel est également adapté pour les modèles :
Alimentation et alimentation - 224893 (163.34 kb)
Alimentation et alimentation - 224894 (163.34 kb)
Alimentation et alimentation - 224895 (163.34 kb)
Alimentation et alimentation - 308178 (163.34 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories