Log:
Évaluations - 4, GPA: 3.8 ( )

Instructions American Power Conversion, Modèle 208 VAC

Fabricant : American Power Conversion
Taille : 1 mb
Nom Fichier : ASTE-6YWRZT_R0_EN.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


The UPS filters small utility line fluctuations and isolates electronic equipment from large disturbances by internally disconnecting fromutility line power. The UPS provides continuous power from the internal battery until utility power returns tosafe levels or the battery is fully discharged. Unpack Read the Safety Guide before installing the UPS. Inspect the UPS upon receipt. Notify the carrier and dealer if there is damage. The packaging is recyclable; save it for reuse or dispose of it properly. Check the package contents: •UPS •Front bezel •Literature kit containing: – EPO connector – Eight snap-on speed nuts – Serial cable Additional contents for – Two rail cleats (required for four post – USB cable rack only) 230 V models: – Eight ornamental screws for – Two rack-mount brackets – APC power cable securing the unit in the rack – Alternate input power cord – Product documentation – Eight 5/16 in (.8 cm) pan-head (UK customers) – Smart-UPS® User Manuals CD screws for attaching cleats to the –IEC Power cord – PowerChute® Business Edition CD chassis rails – IEC jumper cables (required for four post rack only) – Safety information – Eight 5/8 in (1.6 cm) pan-head – Warranty information screws for attaching rack-mount brackets to the unit Specifications TemperatureOperatingStorage 32° to 104° F (0° to 40° C) 5° to 86° F (-15° to 30° C) charge the UPS battery every six months 86° to 113° F (30° to 45° C) charge the UPS battery every three months This unit is intended for indoor use only. Select a location sturdy enoughto handle the weight. Do not operate the UPS where thereis excessive dust or the temperature or humidity are outside the specified limits. Environmental factors impact battery life. High temperatures, poor utility power, and frequent, short duration discharges will shorten battery life. Maximum Elevation OperatingStorage 10,000 ft (3,000 m) 50,000 ft (15,240 m) Humidity 0 to 95% relative humidity, non-condensing Weight 142 lbs (64 kg) with battery module 89 lbs (40 kg) without battery module 27 lbs (12 kg) each battery module 142 lbs (64 kg) Maximum Number of External Battery Packs Supported by the Smart-UPS XL 10 NOTE: The model and serial numbers are located on a small, rear panel label. For some models, an additional label is located on the chassis under the front bezel. Smart-UPS 2200/3000 VA XL 120/208/230 VAC Tower/Rack-Mount 5U User Manual 4 Smart-UPS 2200/3000 VA XL 120/208/230 VAC Tower/Rack-Mount 5U User Manual Installation The UPS is shipped in tower configuration. Tower Configuration Connect the battery. After the battery has been connected, tuck the battery cables in between the battery and the battery door. This will ensure a secure fit of the bezel to the unit. Smart-UPS 2200/3000 VA XL 120/208/230 VAC Tower/Rack-Mount 5U User Manual 5 Rack-Mount Configuration This unit is intended for mounting in a two post rack. To order a four post rack-mount kit contact your dealer or refer to the APC Web site, Tower to rack-mount conversion procedure The UPS and the battery modules are heavy. Remove the battery modules to lighten the UPS during installation. Remove the top cover and . Remove and rotate the display panel . A four post rack configuration requires installation of two brackets in the forward position (see diagram above), two cleats (supplied with this unit), and the four post rails. The rails can be ordered through the APC Web site Pull the battery disconnect strap attached to the battery connector. DO NOT pull the battery cables to disconnect the battery. Disconnect Battery Battery Disconnect Strap Foam Spacer x4 5/8 in 1.6 cm Four post rack-mount bracket position Two post rack-mount bracket position 6 Smart-UPS 2200/3000 VA XL 120/208/230 VAC Tower/Rack-Mount 5U User Manual Install unit in rack Ensure rack stability prior to installing devices in the rack. The UPS should be installed at or near the bottom of the rack. If external battery packs are to be installed in the rack, the UPS must be the top unit in the configuration. Accessories This UPS is equipped with an accessory SmartSlot. Refer to the APC Web site, for available accessories. If a standard accessory, such as a Network Management card is to be installed on this UPS, refer to the Utility CD for user documentation. Install accessories prior to connecting power to the UPS. After all of the batteries have been connected, tuck the battery cables in between the batteries and the battery doors. This will ensure a secure fit of the bezel to the unit. x4 Ornamental Foam Spacer Connect Battery Smart-UPS 2200/3000 VA XL 120/208/230 VAC Tower/Rack-Mount 5U User Manual 7 Start-Up Connect Equipment and Power to the UPS 1. The UPS features a transient voltage surge-suppression (TVSS) screw located on the rear panel, for connecting the ground lead on surge suppression devices such as telephone and network line protectors. Prior to connecting the grounding cable, ensure that the UPS is NOT con...

Ce manuel est également adapté pour les modèles :
Alimentation et alimentation - 2200 VA XL (1 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories