|
Facilité d'utilisation
Once the pilot is lit, the main burner may be turned ON and OFF using wall switch, remote control, optional on unit rocker switch (FRS), or wall thermostat. To operate: Toggle the switch between its ON and OFF positions. If your millivolt appliance is equipped with an optional remote switch kit (wall switch, remote control, rocker switch, or wall thermostat) and the pilot is lit, the appliance main burner may be turned on and off using the optional switch. Note: To prevent excessive resistance in burner circuit (which can cause burner operation problems), only one burner control switch should be wired to valve. Figure 2 Control Compartment Door Tab Gas Flex Line Gas Shut-Off Valve Valve Piezo Spring Door Latch Lower Control Compartment SUPERIOR SUPERIORDIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS Electronic Appliances Tolightelectronicappliancesrefertothedetailed lighting instructions found on Pages 24 and 25 of these instructions. Electronic appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve. If your electronic appliance is equipped with an optional remote wall switch or remote control kit the appliance main burner may be turned on and off with the wall switch or remote control. If your electronic appliance is not equipped with a wall switch or remote control, the main burner must be turned off and on with a gas control switch located in some other location by the installer. Contact the installer for directions. Check batteries, if installed, routinely (ever three months). TO LIGHT THE APPLIANCE DURING A POWER OUTAGE: • Install batteries in battery pack. • Turn unit mounted switch or wall switch to the ON Position. • Unit should spark at pilot and light. • Operate Normally. • Replace batteries if needed. •Afterpowerisrestored,removebatteries. Note: It is recommended that batteries not be installed in the battery holder until a power outage, or if the appliance is to be operated solely with two (2) "D" batteries. Refer to the Lighting Instructions on Page 24 to lighttheapplianceintheeventofapowerfailure. Figure 3 - SIT Millivolt Gas Valve Gas Inlet Terminals TPTH, TP and TH Gas Outlet Variable Flame Height Adjustment Manifold Pressure PortInlet Pressure Port Main Gas Control Knob HI LOW TPTH TP TH PILOT PILOTON itOFF IN OUT Pressure-Tap Burner Stage (Manifold) Terminal Regulator Gas Supply Gas Mounting Outlet Inlet Screw To Burner Pressure-Tap Pilot Stage (Inlet) Terminal Pilot Gas Outlet Ground (TP) PILOTOUTVENTLOTHTPTHTPHIININ Figure 4 - Dexen Electronic Gas Valve Variable Flame Height Adjustment All millivolt and electronic appliances are equippedwithavariablegascontrolvalve.Flame heightforthesemodelsmaybeadjustedthrough arangebetweenfixedlowandhighsettingswhile the appliance is in operation. Adjust the flame height as desired after lighting the appliance by rotating the variable adjustment control knob (HI/LO) located on the...
Ce manuel est également adapté pour les modèles :Cheminées - SLDVT-30NE (2.16 mb)
Cheminées - SLDVT-30NE (2.16 mb)
Cheminées - SLDVT-30NE (2.16 mb)
Cheminées - SLDVT-30NE (2.16 mb)