Instructions Empire Comfort Systems, Modèle VFD36FB0L-1

Fabricant : Empire Comfort Systems
Taille : 4.64 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


3. Run the other end of the duct through the exterior wall cutout. 4. From the outside of the building, connect the duct to the collar on the outside air vent assembly with band clamp or screws to secure. 5. Mate the outside rain cap hood over the air vent, seal with caulk as necessary, then secure with screws provided to the exterior wall surface. See Figure 22 and 23. 6. Figure 24 illustrates the various options for installation of the air duct run possibilities. OUTSIDE HOOD 4” DIA. AIR DUCT CONNECTOR (INSTALLER SUPPLIED) OUTSIDE PLATE/VENT SCREEN ASSEMBLY AIR DOOR ASSEMBLY FIREBOX OR FIREPLACE Figure 22 Figure 23 Caulk and Install Duct Termination WALL DUCT TERMINATION RAIN CAP CAULKING Figure 24 Page 12 23200-0-1206 OPTIONAL SINGLE SPEED BLOWER INSTALLATION INSTRUCTIONS Attention: Install blower assembly before connecting gas inlet supply line. Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, if an external electrical source is utilized. This appliance is equipped with a three-prong [grounding] plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. For an ungrounded receptacle, an adapter, which has two prongs and a wire for grounding, can be purchased, plugged into the ungrounded receptacle and its wire connected to the receptacle mounting screw. With this wire completing the ground, the appliance cord plug can be plugged into the adapter and be electrically grounded. Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Note: Junction box on right side of firebox must be pre-wired at time of firebox installation for use with blower assembly. A standard wall ON/OFF wall switch or optional SCV1 Variable Speed Control Kit should be installed to activate power to the Firebox, and control the operation of the FBB5 Blower assembly. It is recommended that installation of the wiring be performed by a qualified electrician. See Figure 25. 1. If installed, turn OFF gas supply to firebox/gas log. 2. If applicable, turn OFF electric supply to firebox. CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL, CITY AND STATE BUILDING CODES. BEFORE MAKING THE ELECTRICAL CONNECTION, MAKE SURE THAT MAIN POWER SUPPLY IS DISCONNECTED. THE APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES, WITH THE NATIONAL ELECTRICAL CODE ANSI/NFPA 70 (LATEST EDITION). A factory installed junction box is located on the lower right side of the firebox. Wiring must be fed to the junction box and attached to the receptacle that is provided. From right side of the firebox, remove the screw securing the junction box assembl...

Ce manuel est également adapté pour les modèles :
Cheminées - VFD36FB2CL-1 (4.64 mb)
Cheminées - VFD36FB2DF-1 (4.64 mb)
Cheminées - FD42FB2DF-1 (4.64 mb)
Cheminées - VFD32FB0F-1 (4.64 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories