1 -Turn Off electrical power to appliance. 2 -Allow the appliance to cool. 3 -Remove the lower control compartment access panel. 4 -Refer to Figure 25 on Page 20. Open both latches under the firebox floor securing the glass enclosure panel. Remove the panel by tilting it outward at the bottom and lifting it up. Set aside the panel, taking care to protect it from damage. 5 -Remove the (3) screws securing the lintel, and then remove the lintel. One of the lintel cabinet top holes is shown in Figure 29. 6 -Remove the (3) screws securing the scoop, and then remove the scoop. Refer to Figure 29 for correct location for model size. 7 -Reset the limit switch per Figure 29-B. If unit does not reset, remove the (2) screws securing the safety switch bracket, and NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. pull the switch/bracket assembly (with low voltage wires attached) through the side panel slot into the firebox. 8 -Replace the switch, if necessary.. 9 -Reinstall the scoop and lintel. 10 -Reinstall the glass enclosure panel and control compartment access panel. The appliance should then relight and remain lit. If this does not occur, contact your dealer. SUPERIORSUPERIORB-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS Step 12. Install Hood NOTE: All models must have a hood installed prior to operating. Refer to Figure 30. Install hood by sliding it into the slots on the lower edge of the cabinet top. Step 13. finishing Requirements Wall details Complete finished interior wall. To install the appliance facing flush with the finished wall, position framework to accommodate the thickness of the finished wall (Figure 30). For Cold Climate Insulation, see Page 5. For Clearances, see Page 7. Top of Appliance 1 in (25 mm) min. Figure 30: Combustible Wall Framing Combustible finished Wall Materials Combustible material may touch appliance top. Hood 3" Clearance min. IMPORTANT! Bend up standoffs to vertical position. Header NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. SUPERIORSUPERIORB-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS Step 14. Attach Safety-In-Operation Warnings It is the installer’s responsibility to ensure these warning labels are properly affixed during installation. These warning labels are a critical step in informing consumers of the safe operation of this appliance. COLOCACIoNdEAdVERTENCIASdESEGURIdAd WARNINGS ATTACHING SAfETY-IN-OPERATION APPOSITION dES MISES EN GARdE RELATIVES EN OPERACIoN a LA SeCURITe d’UTILISATION Se requiere que las etiquetas de instrucciones de It is required that the safety instruction labels fur Ilestimperatifquelesetiquettesdesecuritefourniesavec seguridad incluidas con la chimenea se coloquen en nished with the fireplace be affixed to the operation le foyer soient collees a cote des dispositifs de controle el punto de operacion y control de la misma. Se debe andcontrolpointofthefireplace.Asafetyinstruction du foyer. Une etiquette de securite doit etre ...

Ce manuel est également adapté pour les modèles :
Cheminées - SLBV-35NE (2.89 mb)
Cheminées - SLBV-35NE (2.89 mb)
Cheminées - SLBV-35NE (2.89 mb)
Cheminées - SLBV-35NE (2.89 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories