Fabricant : FireplaceXtrordinair
Taille : 1.87 mb
Nom Fichier :
|
Facilité d'utilisation
Not enough fresh air is available for ODS/pilot to operate -Open window and/or door for ventilation. b. Low line pressure - Contact local gas company. c. ODS/pilot is partially clogged - Clean ODS/pilot. d. Defective thermocouple - Replace pilot. 4. Appliance shuts off during use. (Pilot stays on.) a. Low line pressure - Check line pressure to the valve. b. Defective thermopile -Check pilot flame, check wire connections,outputshouldbeaminimumof325millivolts across. TH/TP and TP terminals with ON/OFF switch off. 5. Gas odor even when control knob is in OFF position. a. Gas leak -Locate and correct all leaks. b. Control valve defective - Replace control valve. 6. Whenignitorbuttonispressed,thereissparkatODS/pilot, but no ignition. a. Gas supply turned off or manual shutoff valve closed -Turn on gas supply or open manual shutoff valve. b. Control knob not in PILOT position - Turn control knob to PILOT position. c. Control knob not pressed in while in PILOT position - Press in control knob while in PILOT position. d. Air in gas lines when installed - Continue holding down control knob. Repeat igniting operation until air is removed. e. ODS/pilot is clogged - Replace ODS/pilot assembly or get it serviced. f. Gas regulator setting is not correct -Replace gas regulator. 7. ODS/pilot lights but flame goes out when control knob is released. a. Control knob not fully pressed in - Press in control knob fully. b. Control knob not pressed in long enough - After ODS/pilot lights, keep control knob pressed in 30 seconds. c. Manual Shutoff valve not fully open - Fully open manual shutoff valve. d. Thermocouple connection loose at control valve - Hand tighten until snug, then tighten 1/4 turn more. e. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by either low gas pressure or dirty or partially clogged ODS/pilot - Contact local gas company. f. Thermocouple damaged - Replace thermocouple. g. Control valve damaged - Replace control valve. 8. Burner does not light after ODS/pilot is lit. a. Burner orifice clogged -Clean burner or replace main burner orifice. b. Burner orifice diameter is too small -Replace burner orifice. c. Inlet gas pressure is too low - Contact qualified service person. 9. If burning at main burner orifice occurs (a loud, roaring blow torch noise). a. You must turn off burner assembly and contact a qualified service person. b. Manifold pressure is too low -Contact local gas company. c. Burner orifice clogged - Clean burner or replace burner orifice. 10. Logs appear to smoke after initial operation. a. Vapors from paint or curing process of logs -Problem will stop after a few hours of operation. Run the heater with the damper open if you have one, or open a window for the first few hours. Log heater is intended to be smokeless. Turn OFF heater and call qualified service person. 11. Heater produces a whistling noise when main burner is lit. a. Turning control knob to HIGH position when main burner is cold - Turn control knob to LOW position and let warm up for a minute. b. Air in gas line - Operate burner until air is removed from line. Have gas line checked by local gas company. c. Dirty or partially clogged burner orifice - Clean burner or replace burner orifice. 12. No gas to pilot. a. LP-regulator shut down due to inlet pressure too high - Verify LP tank regulator is installed and set at 11" to 13" w.c. Replace regulator on heater. If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the gas quality or pressure is low, contact your local gas supplier immediately. 20101-0-0306 Page 21 PARTS LIST ATTENTION: When ordering parts, it is very important that part number and description of part coincide. Index Number Part Number VFP32FP(20,21) Part Number VFP32FP(30,31) Part Number VFP36FP(20,21) Part Number VFP36FP(30,31) Description 1 17149 17149 17149 17149 TOP STANDOFF 2 20098 20098 20126 20126 FIREBOX ASSEMBLY 3 10554 10554 10554 10554 NAILING FLANGE 4 20170 20170 20134 20134 INNER FIREBOX TOP 5 17162 17162 17162 17162 JUNCTION BOX ASSEMBLY 6 17448 17448 18802 18802 FRAME, TOP 7 17169 17169 18807 18807 LOUVER ASSEMBLY UPPER 8 20020 20020 20145 20145 HOOD 9 20475 20475 20478 20478 FRAME, RIGHT 10 20476 20476 20479 20479 FRAME, LEFT 11 20095 20095 20143 20143 FRONT FRAME WELDED ASSEMBLY 12 17170 17170 18808 18808 LOUVER ASSEMBLY LOWER 13 P200 P200 P200 P200 FITTING, ORIFICE 14 ---P211 ORIFICE #32 (NAT) 14 --P213 -ORIFICE #37 (NAT) 14 -P243 --ORIFICE #36 (NAT) 14 --P245 P245 ORIFICE #50 (LP) 14 P250 P250 --ORIFICE 1.65MM (LP) 14 P286 ---ORIFICE #42 (NAT) 15 R5675 R5675 R5675 R5675 AIR SHUTTER-FULLY OPEN (LP UNITS) 15 R5676 R5676 R5676 R5676 AIR SHUTTER (NAT UNITS) 16A -R3623 -R3623 PILOT ASSEMBLY LP 16A -R3624 -R3624 PILOT ASSEMBLY NAT 16B R5170 -R5170 -PILOT, LP 16B R5171 -R5171 -PILOT NAT 17 20467 20467 20467 20467 PILOT SHIELD 18 17370 17370 17386 17...
Ce manuel est également adapté pour les modèles :Cheminées - 31)L(N (1.87 mb)
Cheminées - VFP32FP (1.87 mb)
Cheminées - 21)L(N (1.87 mb)
Cheminées - P)-1 (1.87 mb)