Log:
Évaluations - 2, GPA: 4 ( )

Instructions Superior, Modèle STANDARD SERIES CF5500-CMP

Fabricant : Superior
Taille : 598.98 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Clean and/or adjust pilot flame for maximum flame impingement on thermopile (Figure 19). LIGHTING INSTRUCTIONS – MILLIVOLT WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. FOR YOUR SAFETY READ BEFORE LIGHTING • Do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. • If your gas supplier cannot be reached, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or an explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS • Extinguish any open flame. • Open windows. • Do not light any appliance. • Do not touch any electrical switches. LIGHTING INSTRUCTIONS 1. STOP! Read the safety information above on this page. 2. Access left side louver. 3. Turn remote wall switch to “OFF.” 4. Verify main line shut-off valve is open. 5. Push in gas control knob slightly and turn clockwise to “OFF.” Note:Knob cannot be turned from “PILOT” to “OFF” unless the knob is pushed in slightly. Do not force. 6. Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow “B” in the safety information above on this page. If you do not smell gas, go to the next step. 7. Push in gas control knob slightly and turn counterclockwise to “PILOT.” 8. Push in control knob all the way and hold in. Immediately light the pilot by triggering the spark ignitor (pushing red button) until pilot lights. Continue to hold the control knob in for about 1 ... minutes after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8. • If knob does not pop up when released, stop and immediately call your service technician or gas supplier. • If pilot will not stay lit after several tries, turn the control knob to “OFF” and call your service technician or gas supplier. 9. Turn gas control knob counterclockwise to “ON.” 10. Close the side louver. Note:If the gas valve is turned directly from the “ON” to “OFF” position, the valve will latch in the “OFF” position for 60 seconds. Thermopile Ignitor Thermocouple E A TPTH TP TH PILOT PILOTON it OFF SIT Millivolt Valve Gas Control Knob Piezo Ignitor Flame Adjustment Knob Honeywell Millivolt Valve Gas Control Knob Spark Ignitor ON OFF PILOT LO HI TO TURN OFF GAS TO APPLIANCE 1. Turn remote wall switch “OFF.” The pilot will remain lit for normal service. 2. For complete shutdown, turn remote wall switch to “OFF.” 3. Access the left side louver. 4. Depress gas control knob slightly and turn clockwise to “OFF.” Do not force. 5. Close the side louver. REPLACEMENT PARTS LIST — MILLIVOLT REPLACEMENT PARTS LIST — MILLIVOLT CF5500-CMN CF5500-CMP CF6500-CMN CF6500-CMP No. DESCRIPTION Part No. Qty. Part No. Qty. 20. Gas Valve - SIT 901916 1 901917 1 Gas Valve - Honeywell 67L0101 1 67L0201 1 21. Piezo Igniter 111061 1 111061 1 22. Orifice/CF5500 903461 1 901694 1 Orifice/CF6500 903883 1 901699 1 2...

Ce manuel est également adapté pour les modèles :
Cheminées - STANDARD SERIES CF5500-CMN (598.98 kb)
Cheminées - STANDARD SERIES CF5500-CMN (598.98 kb)
Cheminées - STANDARD SERIES CF5500-CMN (598.98 kb)
Cheminées - STANDARD SERIES CF5500-CMN (598.98 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories