Log:
Évaluations - 5, GPA: 3.6 ( )

Instructions Enviro, Modèle FOCUS EG31-118

Fabricant : Enviro
Taille : 1.84 mb
Nom Fichier : Focus-Owners-Manual.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


If any parts have been damaged or are missing, contact your dealer, distributor or courier company to have them replaced before starting this installation. Conversion Kit Installation: 1. Turn control knob on the gas valve to the “OFF” position and shut the gas supply off at the shut-off valve upstream of the unit. CAUTION: The gas supply must be shut off prior to disconnecting the electrical power and before proceeding with the conversion. Allow the valve and unit to cool down to room temperature. 2. Remove the glass as shown in the MAINTENANCE AND SERVICE - OPENING THE DOOR. 3. Carefully remove the log set and ember material if they are installed. 4. Remove the burner as shown in the MAINTENANCE AND SERVICE - BURNER REMOVAL. 5. Convert the burner orifice(s): a) Remove the main burner orifice with a 1.2 inch deep socket. b) Put a bead of pipe-thread sealant or approved Teflon tape on the orifice threads before installing into the brass elbow. c) Install the new orifice(s) from the kit into the brass elbow. 6. Convert the pilot injector: a) Pull the pilot hood straight up to access the pilot injector. b) Using a 5/32” or 4 mm Allen key, remove the pilot injector. c) Install the new pilot injector supplied with this conversion kit. Simply screw the new injector inside the pilot hood using the Allen key, d) Reinstall the hood by placing the hood on the assembly, line up the key way, and snap into place. Figure 8: Removing valve cap. 1 7. Convert the SIT gas valve: a) Remove the black protection cap from the HI/LO knob by hand shown in Figure 8. b) Insert a 5/32” or 4 mm Allen wrench into the hexagonal key-way of the screw (see Figure 9), rotate it counter-clockwise until it is free and extract it. c) Check that the screw is clean and if necessary remove dirt. d) Flip the screw (refer to Figure 10). e) Using the Allen wrench as shown in Figure 9, rotate the screw clockwise until a torque of 9 inch lbs. WARNING! Do not over tighten the screw. It is recommended that you grip the wrench by the short side. f) Verify that if the conversion is from NG to LPG, the screw must be re-assembled with the red o- ring visible (refer to Figure 11). If the conversion is from LPG to NG, the red o-ring of the screw must be not visible. g) Re-attach the black protection cap that was removed in step a (Figure 8). 8. Reinstall the burner, brick panels, log set, embers, and glass door. Also refer to SECONDARY INSTALLATION - INSTALLING LOG SET AND EMBERS. When re-installing the burner, ensure that the burner to pilot hood relationship is similar to what is shown in Figure 12. On some units you will need to pay special attention when installing the burner that the venturi adjustment rod is properly installed into the venturi adjustment piece welded to the burner venturi tube 9. Reconnect the main gas line if it was disconnected and open the shut-off valve at the gas line to the unit. 10. Use a small brush to apply a warm soapy water solution to all gas connections (use a half dish soap and half warm water). If a gas leak is present, bubbling will occur. Gas leaks can be repaired by using an approved pipe thread sealant or approved Teflon tape. NEVER USE AN OPEN FLAME WHEN TESTING FOR LEAKS. 11. Reconnect the electrical power to the unit. 12. Relight the main burner in both the “HI” and “LO” positions to verify proper burner ignition and operation and proper flame appearance. Also refer to SECONDARY INSTALLATION - LOG SET AND EMBERS INSTALLATION for a flame appearance picture. 13. MAKE SURE that the conversion label is installed on or close to the rating label to signify that the unit has been converted to a different fuel type. Maintenance And Service Figure 10: Flip valve screw. Figure 9: Removing valve screw. Figure 11: O-ring on valve screw. Figure 12: Burner to pilot hood relationship. 1 Initial Installation WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. Warning: Failure to position the parts in accordance with this manual, or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. CLEARANCES TO COMBUSTIBLES: Mantle pillar to glass door 9” (22.8 cm) From floor to 8” wide mantle 38” (96.5 cm) Minimum non-combustible surface in front of unit 11” (27.9 cm) Warning: Clearances must be sufficient to allow access for operation, maintenance and service. Stove must sit on a non-combustible surface. Depth of unit into fireplace 16” (41 cm) Depth of unit out of fireplace 3’’ (7.6 cm) Minimum fireplace size: Width 34” (86.36 cm) Height 21” (53.3 cm) Depth 18” (45.7 cm) B VENT MODEL: WARNING: This appliance has been designed to operate by drawing combustion air and dilution air from the room. It is also designed to draw room air for proper heat circulation from the sides of the unit. Blocking or modifying the louvers in any way can create hazardous situation...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories