Fabricant : Empire Comfort Systems
Taille : 1.05 mb
Nom Fichier : ca8f35c2-18f2-4ff8-8efe-23293a89ff34.pdf
|
Facilité d'utilisation
• Do not use the phone in your building. • Immediately call your gas supplier from a neighbor's phone. • Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL CAST IRON VENTED FIREPLACE HEATER MODEL CIBV-30-2 EFFECTIVE DATE APRIL, 2000 WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Installation and service must be performed by a qualified installer, service agency, or the gas supplier. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. AVERTISSEMENT: Quiconque ne respecte pas a la lettre les instructions dans le present manuel risque de declencher un incendie ou une explosion entraiant des dommages materiels, des lesions corporelles ou la perte de vies humaines. Installation ou modification, consulter le manuel des usagers fourn avec ce generateur d'air chaud. Ne pas entreposer ni utiliser d'essence ni d'autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tour autre appareil. POUR VOTRE SECURITE: Que faire si vous sentez une odeur de gaz: • Ne pas tenter d'allumer d'appareil. • Ne touchez a aucun interrupteur. Ne pas vous servir des telephones se trouvant dans le batiment ou vous vous trouvez. • Evacuez la piece, le batiment ou la zone. • Appelez immediatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur. • Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service dos incendies. Introduction Specifications Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of a vented fireplace heater. Instructions to Installer 1. Installer must leave instruction manual with owner after installation. 2. Installer must have owner fill out and mail warranty card supplied with heater. 3. Installer should show owner how to start and operate heater and thermostat. WARNING:Any change to this fireplace heater or its controls can be dangerous. Any safety screen or guard removed for servicing a fireplace heater must be replaced prior to operating the fireplace heater. General Information This appliance is design certified in accordance with American National Standard /Canadian Gas Association Standard ANSI Z21.88-1998 and CSA 2.33-M98 by the American Gas Association and Canadian Gas Association, as a Vented Fireplace Heater and must be installed according to these instructions. Any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and company making the change. Important All correspondence should refer to complete Model No., Serial No. and type of gas. Notice: During initial firing of this unit, its paint will bake out and smoke will occur. To prevent triggering of smoke alarms, ventilate the room in which the unit is installed. Installation on Rugs and Tile If this appliance is to be installed directly on carpeting, tile, or other combustible material, other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance. The base referred to above does not mean the fire-proof base as used on wood stoves. The protection is primarily for rugs that may be extremely thick and light-color tile that can discolor. WARNING: If not installed, operated and maintained in accordance with the manufacturer's instructions, this product could expose you to substances in fuel or from fuel combustion which can cause death or serious illness. Model CIBV-30 Input BTU/HR (KW/H) Max. (LP/NAT) 30,000 (8.7) BTU/HR (KW/H) Min. (LP) 22,000 (6.4) BTU/HR (KW/H) Min. (NAT) 19,500 (5.7) Height 27 3/4" (8.7cm) Width 25 1/2" (64.8cm) Depth including diverter 21" (53.3cm) Gas Inlet 1/2" (13mm) Size Draft Diverter Collar 4" (10.16cm) Floor to top of collar on vertical position of Draft Diverter 27 3/8" (69.5cm) Floor to center of collar on horizontal position of Draft Diverter 23 1/2" (59.7cm) Stove Casting (Must be ordered with Firebox.) CIFB-1 Flat Black CIPB-1 Porcelain Black CIPG-1 Porcelain Green CIPS-1 Porcelain Sand CIPN-1 Porcelain Navy CIPR-1 Porcelain Red Accessories GWSG-T 750 Millivolt Thermostat FRBC-1 Battery Operated Remote Control FRBTC-1 Battery Operated Remote Control with Thermostat FREC-1 Electric Remote Control FWS-1 Wall Switch CIB-2 Automatic Blower Stone Inlay Replaces Standard Grille Top CII-2 Stone Inlay Empress Green CII-3 Stone Inlay Hunan Jade CII-4 Stone Inlay Gray Botticino CII-5 Stone Inlay Azul CII-6 Stone Inlay Salome CII-7 Stone Inlay Black Swan WARNING: Do not operate appliance with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person. THIS IS A HEATING A...