Log:
Téléchargements : 4   Taille : 2 mb   Fabricant : Quadra-Fire  
Catégorie : Cheminées
@name

B • 12/08 7 77 Installation Preparation Prepare the existing solid fuel masonry or factory built non-combustible firebox for installation. A. Inspection and Cleaning Prior to installing the gas insert: • Have the chimney and adjacent structure inspected and cleaned by qualified professionals. Hearth & Home Technologies recommends that NFI or CSIA certified professionals, or technicians under the direction of certified professionals, conduct a minimum of a NFPA 211 Level 2 inspection of the chimn

Téléchargements : 0   Taille : 4 mb   Fabricant : Quadra-Fire  
Catégorie : Cheminées
@name

the jumper wires across the terminals at the switch. If the burner the valve knob is in the ON comes on, replace the defective switch. If the switch is OK, place the position, and the ON/OFF jumper wires across the switch wires at the gas valve. If the burner switch is in the ON position. comes on, the wires are faulty or connections are bad. b. Thermopile may not be gener- If the pilot flame is not close enough physically to the thermopile, ating suffi cient millivoltage. adjust the pilot flame

Téléchargements : 0   Taille : 2 mb   Fabricant : Quadra-Fire  
Catégorie : Cheminées
@name

• Install gas line into hole provided on insert side. • If applicable install remote control wires into insert side (see Section 6, F.). • Secure collar slide plate to appliance by placing locking handle into position with locking tabs (see Figure 7.1) and secure with #8 screw. • Level the appliance from side to side and front to back. If necessary, use the leveling legs included with the manual bag to set each corner of the base. • Position any excess flexible vent pipe back up into chimney wit

Téléchargements : 6   Taille : 5 mb   Fabricant : Quadra-Fire  
Catégorie : Cheminées
@name

Figure 6.3 Minimum Clearances for Termination CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED. WARNING! In the U.S.: Vent system termination is NOT permitted in screened porches. You must follow side wall, overhang and ground clearances as stated in the instructions. In Canada: Vent system termination is NOT permitted in screened porches. Vent system termination is permitted in porch areas with two or more sides open. You must fo

Téléchargements : 0   Taille : 5 mb   Fabricant : Quadra-Fire  
Catégorie : Cheminées
@name

• Do not store or use gasoline or other flammable vapors and liquids in the vicinity ofthis or any other appliance. • What to do if you smell gas: -Do not try to light any appliance. -Do not touch any electrical switch. Do notuse any phone in your building. -Immediately call your gas supplier froma neighbor’s phone. Follow the gas supplier’s instructions. -If you cannot reach your gas supplier, call the fi re department. • Installation and service must be performed by a qualified installer, serv

Téléchargements : 2   Taille : 5 mb   Fabricant : Quadra-Fire  
Catégorie : Cheminées
@name

Place existing screw head (installed in Figure 23.2) into locator hole in floor of insert. Figure 23.2. 6. Lift hopper lid and press down on panel top while installing (4) 8-32 x 3/8 inch screws into holes in panel support. (If screws have been factory installed, tighten to secure panel to panel support.) Return hopper lid to closed position. 7. Install a corner bracket on each side trim piece. Slide brackets into top trim from each side and secure with flathead screwdriver. Attach trim assembly

Téléchargements : 0   Taille : 5 mb   Fabricant : Quadra-Fire  
Catégorie : Cheminées
@name

Example 2: If the equivalent length of pipe is 12 feet (3.7m) with altitude of 6,000 feet (1829m) you may use 3 or 4 inch (76 to 102mm) diameter type “L” or “PL” vent Fire Risk. Do NOT pack insulation or other combustibles between firestops. • ALWAYS maintain specified clearances around venting and firestop systems. • Install firestops as specified. Failure to keep insulation or other material away from vent pipe may cause fire. WARNING Page 14 7014-188B February 3, 2010 R R February 3, 2010 701

Téléchargements : 0   Taille : 2 mb   Fabricant : Quadra-Fire  
Catégorie : Cheminées
@name

Be sure to release air pressure from the gas line before connection is made totheappliance.Excessivepressurewilldamagethegas control and may cause a gas leak. • GasLeakTest:Makesurethegasconnectionsaretight. Turn on the gas and coat each joint with a non-corrosive gas leak check solution. Air bubbles will form indicating any leaks. DO NOT USE A FLAME OR ANY TYPE OF IGNITION SOURCE TO CHECK FOR LEAKS. All leaks must be corrected before proceeding with installation. 0 Quadra-Fire • Fogata Grande O

Téléchargements : 0   Taille : 2 mb   Fabricant : Quadra-Fire  
Catégorie : Cheminées
@name

• Leavethismanualwith party responsible for use and operation. • Read,understandandfollow these instructions for safe installation and operation. WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death. • Do not store or use gasoline or other flammable vapors and liquids in the vicinity ofthis or any other appliance. • What to do if you smell gas: - Do not try to light any appliance. - Donottoucha

Téléchargements : 7   Taille : 6 mb   Fabricant : Quadra-Fire  
Catégorie : Cheminées
@name

• By: Qualified Service Technician/Homeowner Be sure the appliance is allowed to cool, has been unplugged and the exhaust blower is off. The products of combustion will contain small particles of fly ash. The fly ash will collect in the exhaust venting system and restrict the flow of the flue gases. At start-up if there is incomplete combustion, or if there is a shutdown or incorrect operation of the appliance it will lead to some soot formation. This will collect in the exhaust venting system.





catégories