Log:
Téléchargements : 20   Taille : 3 mb   Fabricant : Desa  
Catégorie : Cheminées
@name

FOR YOUR SAFETY Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance. FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch. • Do not use any phone in your building. • Immediatly call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fi re department. This appliance may be installed in an a

Téléchargements : 16   Taille : 6 mb   Fabricant : Desa  
Catégorie : Cheminées
@name

7. Twist-lock the vent cap onto the kast section of vent pipe. Note: If the vent pipe passes through any occupied areas above the first floor, including storage spaces and closets, you must enclose pipe. You may frame and sheetrock the enclosure with standard construction material. Make sure and meet the minimum allowable clearances to combustibles. Do not fill any of the required air spaces with insulation. If area above is a room, install If the area above is not a room, install firestop above

Téléchargements : 5   Taille : 6 mb   Fabricant : Desa  
Catégorie : Cheminées
@name

WARNING: This appliance, when installed must be electrically grounded in accordance with local code or in the absence of local code, with the current National Electric Code, ANSI/NFPA 70, or the Canadian Electric Code, CSA C22.1. Figure 32 - Relocating Junction Box Receptacle and Electrical Supply Connection A pre-wired junction box receptacle with strain relief is provided on the right side of the cabinet for hard wiring the unit to a 15 Amp, 120VAC, 60Hz grounded branch circuit. If the install

Téléchargements : 2   Taille : 1 mb   Fabricant : Desa  
Catégorie : Cheminées
@name

(7.6 cm) 9" Min. (22.8 cm) 12" Min. (30.4 cm) 33° 6" Nom. (15.2 cm) 1 1/2" Max. (3.8 cm) Drywall2" X 4" StudCombustibleMaterials Figure 9 - Hearth Extensions Noncombustible Hearth Extension 8" Max. “K” Factor.841 1/2" Typ. 1 1/2" Typ. “Z” Type Ember Protector Figure 11 - Mantel Clearances to Combustible Materials Noncombustible Hearth Extension Seal Gaps withNoncombustibleMortar or AdhesiveTop View of FireplaceDrywall4" (Approx.) (10.1 cm)33° Nom. 6" Nom. (15.2 cm) 4 3/8" Min. (11.1 cm) Combusti

Téléchargements : 2   Taille : 6 mb   Fabricant : Desa  
Catégorie : Cheminées
@name

115603-01A OUTSIDE AIR KIT INSTALLATION GAS LINE INSTALLATION 7 OUTSIDE AIR KIT INSTALLATION The installation of the outside air kit must be installed during the rough framing of the fireplace due to the nature of its location. Outside combustion air can be accessed through an exterior wall or a vented crawl space (see Figure 13). CAUTION: Air inlet ducts must not terminate in attic space. The maximum height for the air inlet above the platform of fireplace is a minimum of 3 feet below the chimn

Téléchargements : 0   Taille : 1 mb   Fabricant : Desa  
Catégorie : Cheminées
@name

In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain replacement parts or accessory items when needed. Keep it with your other important papers. Thisfireboxisapprovedforuseasawoodburningfirebox or for use with a vented gas log approved to ANS Z21.60, Z21.84 or RGA 2-72 standards or for use with a vent-free gas log heater approved to ANS Z21.11.2 standard. This wood burning firebox complies with UL127-CAN/ULSS610

Téléchargements : 17   Taille : 2 mb   Fabricant : Desa  
Catégorie : Cheminées
@name@name

6' Max. Ceiling Support Pipe 12S-8DM Return Elbow 6' Max. 6' Max. Offset Elbow Offset Elbow Return Elbow 6' Max. 6' Max. Offset Elbow C A B Figure 9 - Typical Offset Installation Venting Installation Continued See Detail A Ceiling Support Pipe 12S-8DM 2" Min. See Detail B Straps Straps Straps Straps Detail A Return Elbow Detail B Angle Firestop Figure 10 - Ceiling Support Pipe 12S-8DM OFFSET RISE CHIMNEY LENGTH A B 48" 36" 24" 18" 12" 4 3/8" 16 3/8" ELBOW SET ONLY 9 3/4" 25 1/2" 1 12 3/4" 30 3/4

Téléchargements : 3   Taille : 2 mb   Fabricant : Desa  
Catégorie : Cheminées
@name@name

Combustible materials above 9" and projecting more than 1 1/2" from fireplace must not be placed less than 12" from top opening of fireplace (NFPA STD 211, Sec. 7-3.3.3). Mantels or any other combustible material may come up to side edge of black metal face of fireplace if projection from front face falls within limits shown in Figure 5. Fan/Blower Kit assembly Fan or blower kit is optional with this fireplace (for circulating models only). Use of blowers or fans other than those manufactured by

Téléchargements : 6   Taille : 2 mb   Fabricant : Desa  
Catégorie : Cheminées
@name@name

In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain replacement parts or accessory items when needed. Keep it with your other important papers. This fireplace is approved for use as a wood burning fireplace or for use with a vented gas log approved to ANS Z21.60, Z21.84 or RGA 2-72 standards or for use with a vent- free gas log heater approved to ANS Z21.11.2 standard. A DESA Heating, LLC hood must be installed

Téléchargements : 3   Taille : 2 mb   Fabricant : Desa  
Catégorie : Cheminées
@name@name

Bi-Fold Glass Door BDB36 - Black BDB36B - Brushed Brass BDB36P - Platinum Storm Collar SC1-1 For RT-8DM and RTL-8DM SC1-2 For RTT-8DM and RTTL-8DM Firestop Spacer V3600FS-8DM Fan Kit - BK3 Blower Kit - BK Round Top Terminations RT-8DM, RTL-8DM, RT-8HT, RLT-8HT Round Top Terminations with Slip Section RTT-8DM, RTTL-8DM, RTT-8HT, RLTT-8HT Outside Air Kit for Side Wall Installation - AK4 Outside Air Kit for Floor Installation AK4F Square Chase-Top Termination ET-8DM, ET-8DM, ET-8HT Square Top Termi





catégories