Instructions Friedrich, Modèle 9368987053

Fabricant : Friedrich
Taille : 1.89 mb
Nom Fichier : 777fe920-47de-4948-bf3c-0add613f1532.pdf
Langue d'enseignement: enesfr
Aller à la télécharger



Facilité d'utilisation


Do not use in applications involving the storage of foods, plants or animals, precision equipment, or art works. Do not apply any heavy pressure to radiator fins. Operate only with air filters installed. Do not block or cover the intake grille and outlet port. Ensure that any electronic equipment is at least one metre away from either the indoor or outdoor units. Avoid installing the air conditioner near a fireplace or other heating apparatus. When installing the indoor and outdoor units, take precautions to prevent access by infants. Do not use inflammable gases near the air conditioner. En-1 NAME OF PARTS Remote controller SU MO TU WE TH FR SA 36 9 12 15 18 21 DAY OFF DELETE SET ENERGY SAVE THERMO SENSORSET BACK DAY CLOCK ADJUST E27890ABHGFIJD134C56 1 Start/Stop Button 2 Set Temperature Button 3 Master Control Button 4 Fan Control Button 5 THERMO SENSOR Button 6 ENERGY SAVE Button 7 Timer Mode (CLOCK ADJUST) Button 8 DAY (DAY OFF) Button 9 SET BACK Button 0 Set Time Button A DELETE Button B SET Button C Vertical Airflow Direction and Swing Button D Operation Lamp E Timer and Clock Display F Operation Mode Display G Fan Speed Display H Operation Lock Display I Temperature Display J Function Display Defrost Display Thermo Sensor Display Energy Save Display Vertical Swing Display En-2 PREPARATORY OPERATION CLOCK ADJUST Press the timer mode (CLOCK ADJUST) button for 2 seconds or more. The time display on the remote controller will flash. 2 DAY OFF DAY SU MO TU WE TH FR SA Press the DAY button and select the current day. A appears around the selected day. 1 Set the current day and time Press the set time buttons to set the current time. Press repeatedly to adjust the current time in 1minute increments. Press and hold to adjust the current time in 10-minute increments. ex. Monday, 10:00 A.M. Press again to end. CLOCK ADJUST 3 4 SU MO TU WE TH FR SA OPERATION Instructions relating to heating are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). To start/stop operation Operation lamp Air conditioner ON: Lit brightly Air conditioner OFF: Not lit Press the start/stop button. To set the operation mode Operation mode setting AUTO COOL DRY HEAT FAN Press the master control button to set the operation mode. If DRY is selected, the fan speed will be set to AUTO. Room temperature setting Lower Rise Temperature setting range AUTO ............................................... 64 to 88 °F COOL/DRY ....................................... 64 to 88 °F HEAT ................................................ 60 to 88 °F Press the set temperature buttons to set the room temperature. Fan speed setting AUTO HIGH MED LOW Press the fan control button to set the fan speed. En-3 OPERATION Press the ENERGY SAVE button to start or stop the energy-saving air conditioner operation. For details on the function, refer to page 9. ENERGY SAVE Room temperature sensor selection Energy save THERMO SENSOR Press the THERMO SENSOR button to select whether the room temperature is detected at the indoor unit (remote sensor) or the remote controller. When the thermo sensor display appears, the room temperature is detected at the remote controller. NOTES • This function is locked at the factory. In order to detect the room temperature correctly, consult authorized service personnel when using this function. • If this function is locked, the location where the room temperature is detected cannot be changed and the mark flashes when the THERMO SENSOR button is pushed. Indoor unit Part lock function DAY OFF DELETE SET SET BACK DAY CLOCK ADJUST Press the DAY (DAY OFF) button and SET button simultaneously for 2 seconds or more to activate the part lock function and lock all of the buttons on the remote controller except the Start/Stop button, Set Temperature buttons, Master Control button, and Fan Control button. Press the buttons again for 2 seconds or more to deactivate the part lock function. When the part lock function is activated, the mark appears. If any button is pressed during the part lock, the PLdisplay flashes. En-4 TIMER FUNCTIONS OFF timer (See page 5.) Use this timer function to stop air conditioner operation. The timer operates and air conditioner operation stops after the set time has passed. The timer can be set up to 24 hours in advance. ON timer (See page 5.) Use this timer function to start air conditioner operation. The timer operates and air condition operation starts after the set time has passed. The timer can be set up to 24 hours in advance. WEEKLY timer (See page 6.) Use this timer function to set operating times for each day of the week. Use the DAY OFF setting to switch off timed operation for a selected day in the coming week. Because all days can be set together, the weekly timer can be used to repeat the timer settings for all of the days. Temperature SET BACK timer (See page 8.) Use this timer function to change the set temperature in the operation times set for each day of the week. This can be used together with o...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories