Log:
Évaluations - 1, GPA: 4 ( )

Instructions Panasonic, Modèle CS-C12DKU

Fabricant : Panasonic
Taille : 6.29 mb
Nom Fichier : 76b69952-3838-480b-b69a-297c2c462cdb.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Indoor Fan Speed Control 21 2 Functions 3 8.6. Outdoor Fan Speed Control 23 3 Product Specifications 6 8.7. Vertical Airflow Direction Control 23 3.1. CS-C9DKU CU-C9DKU 6 8.8. Horizontal Airflow Direction Control 24 3.2. CS-C12DKU CU-C12DKU 8 8.9. Powerful Operation 24 4 Dimensions 10 8.10. Quiet Operation 25 4.1. Indoor Unit & Remote Control 10 8.11. Timer Control 26 4.2. Outdoor Unit 11 8.12. Random Auto Restart Control 26 5 Refrigeration Cycle Diagram 12 8.13. Remote Control Signal Receiving Sound 26 6 Block Diagram 13 8.14. Economy Mode Operation 27 7 Wiring Diagram 14 9 Operating Instructions 28 8 Operation Details 15 10 Installation Instructions 34 8.1. Cooling Operation 15 10.1. Safety Precautions 34 8.2. Soft Dry Operation 16 10.2. Attached accessories 36 8.3. Automatic Operation 17 10.3. Select the best location 36 8.4. Operation Control 18 10.4. Indoor/Outdoor Unit Installation Diagram 36 © 2005 Panasonic HA Air-Conditioning (M) Sdn Bhd (11969-T). All rights reserved. Unauthorized copying and distribution is a violation of law. CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU 10.5. Indoor unit 37 10.6. Outdoor unit 40 11 2-way, 3-way Valve 45 11.1. Evacuation of Installation 46 11.2. Pumping down 47 11.3. Evacuation of Re-installation 48 11.4. Balance refrigerant of the 2-way, 3-way valves 49 11.5. Evacuation 50 11.6. Gas charging 51 12 Servicing Information 52 12.1. Distinction of Lead Free (PbF) Printed Circuit Board 52 12.2. Indoor Electronic Controller Removal Procedures 52 12.3. Indoor Fan Motor and Cross Flow Fan Removal Procedures 54 12.4. Auto OFF/ON Button 55 12.5. Remote Control Reset 56 1 Features • High Efficiency • Compact Design • Wider range of horizontal discharge air. • Air Filter with function to reduce dust and smoke. • Automatic air swing and manual adjusted by Remote Control for vertical airflow. • Long installation piping. . CS/CU-C9DKU, long piping up to 33ft. . CS/CU-C12DKU, long piping up to 49ft. 13 Troubleshooting Guide 57 13.1. Refrigeration cycle system 57 13.2. Relationship between the condition of the air conditioner and pressure and electric current 58 13.3. Diagnosis methods of a malfunction of a compressor 58 14 Technical Data 59 14.1. Thermostat characteristics 59 14.2. Operation characteristics 60 15 Exploded View (Indoor Unit) 64 16 Replacement Parts List (Indoor Unit) 65 17 Exploded View (Outdoor Unit) 66 18 Replacement Parts List (Outdoor Unit) 67 19 Electronic Circuit Diagram 68 19.1. Indoor Unit 68 19.2. Remote Control 74 19.3. Print Pattern Indoor Unit Printed Circuit Board 75 • Quality Improvement . Random auto restart after power failure for safety restart operation. . Gas leakage protection. . Prevent Compressor reverse cycle. . Inner protector to protect Compressor. . Noise prevention during soft dry operation. . Blue Coated Condenser for high resistance to corrosion. • Operation Improvement . Quiet mode to provide quiet operation. . Powerful mode to reach the desired room temperature quickly. . 24-hour timer setting. • Serviceability Improvement . Removable and washable Front Panel. 2 2 Functions . 3 CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU 4 CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU 5 CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU 3 Product Specifications 3.1. CS-C9DKU CU-C9DKU Unit Indoor unit Outdoor unit Power Source (Phase, Voltage, Cycle) o, V, Hz Single, 115, 60 Cooling Capacity kW (BTU/h) 2.58 (8,800) Moisture Removal l/h (Pint/h) 1.0 (2.1) Airflow Method OUTLET INTAKE SIDE VIEW TOP VIEW Air Volume Lo m3/min (cfm) 4.7 (164) -4.7 (164) — Me m3/min (cfm) 5.7 (202) -5.7 (202) — Hi m3/min (cfm) 7.2 (250) -7.2 (250) 33.8 (1,190) SHi m3/min (cfm) 7.8 (274) -7.8 (274) — Noise Level dB (A) High 36 -36, Low 26 -26 High 49 Power level dB High 49 -39 High 62 Electrical Data Input Power W 790 Running Current A 7.2 EER W/W (BTU/hW) 3.27 (11.10) Starting Current A 42.0 Piping Connection Port (Flare piping) inch inch G ; Half Union 3/8” L ; Half Union 1/4” G ; 3-way valve 3/8” L ; 2-way valve 1/4” Pipe Size (Flare piping) inch inch G ; (gas side) 3/8” L ; (liquid side) 1/4” G ; (gas side) 3/8” L ; (liquid side) 1/4” Drain Hose Inner diameter inch (mm) 20/32 (16) — Length inch (mm) 25-19/32 (650) — Power Cord Length m — — Number of core-wire — — Dimensions Height inch (mm) 11 -1/32 (280) 21 -1/4 (540) Width inch (mm) 31 -15/32 (799) 30 -23/32 (780) Depth inch (mm) 7 -7/32 (183) 11 -3/8 (289) Net Weight lb (kg) 20 (9.0) 64 (29) Compressor Description — Rotary (1 cylinder) rolling piston type Motor Type — Induction (2-poles) Rated Output W — 600 Fan Motor Description Cross-flow Fan Propeller Fan Material ASG32K1 PP Resin Type Induction (4-poles) Induction (6-poles) Input W 60.61 85.8 Rated Output W 15 30 Fan Speed Low rpm 750 -750 — Medium rpm 920 -920 — High rpm 1,160 -1,160 845 SuperHigh rpm 1,250 -1,250 — Heat Exchanger Description Evaporator Condenser Tube material Copper Copper Fin material Aluminium (Pre Coat) Aluminium (Blue Coat) Fi...

Ce manuel est également adapté pour les modèles :
Climatiseurs - CS-C9DKU (6.29 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories