|
Facilité d'utilisation
Consult a qualified installer, service agency, or your distributor or dealer for information and assistance. The qualified installer or agency must use factory-authorized parts or accessories when modifying this product. Refer to the individual instructions packaged with the parts or accessories when installing. Follow all safety codes. Wear safety glasses and work gloves. Read these instructions thoroughly and follow all warnings or cautions attached to the unit. Always install units in accordance with local building codes, the National Electric Code (NEC), and the Installation Standards, Warm Air Heating and Air Conditioning Systems ANSI/NFPA 90B for special installation requirements. GENERAL RECOMMENDATIONS (DO’S AND DON’T’S) DO read the instructions completely before installation. DO take time to perform a quality installation. DO NOT obstruct or restrict indoor or outdoor air paths. When using flex duct: DO install properly. DO NOT crush or make sharp bends in flex duct, use only gradual bends. DO tape and seal all duct joints. DO check the indoor conditioned air duct system static pressure losses. It should not exceed those listed in Table 2. Consult your dealer or distributor for more information. When designing indoor supply systems, DO NOT reduce air intakes or discharge sizes. DO insulate ALL conditioned air duct system components. DO NOT locate room thermostat near conditioned air diffusers. DO locate thermostat on an interior wall. DO check that condensate drain line drains freely. DO NOT let debris fall and collect in indoor or outdoor blowers. DO NOT drill into unit (except for 1 in. flanges for ducted return units). This could cause a refrigerant leak. DO handle unit with care. DO provide minimum installation and service clearances. DO build closet so that unit may be removed if necessary. DO follow all guidelines for indoor and outdoor air system. DO NOT substitute any components without checking with your dealer or distributor. If you do substitute, get approval in writing. Substitutions without approval void unit warranty. DO NOT guess, consult your dealer or distributor if any portion of the installation procedure is unclear. UNPACK AND INSPECT UNIT Remove shipping protection and pallet from unit and inspect for damage. Be sure to check for concealed internal shipping damage. Do not install a damaged unit. SUPPLIES NEEDED FOR INSTALLATION The following items are required to install unit. Adhesive, aluminum duct tape. CAUTION: Incorrect type of duct tape may be a fire hazard. A failure to follow this warning could result in a fire and personal injury or death. 6-conductor thermostat cable (20 gage wire minimum). CAUTION: Do not use thermostat wire with less than the recommended number of conductors. Supplies to connect indoor air (conditioned air supply) duct to unit. Supplies to connect power to unit. Supplies to connect outdoor-air duct to unit. Supplies to connect condensate drain line. Supplies to connect low-voltage thermostat to unit. Section I . General Specifications VERT-I-PAK® MODEL IDENTIFICATION GUIDE MODEL NUMBER V H B 36 K 10 RT A SERIES V=Vertical Series E=Cooling with or without electric heat H=Heat Pump DESIGN SERIES A = 32" Cabinet B = 68" Cabinet NOMINAL CAPACITY VOLTAGE K = 208/230V-1Ph-60Hz ELECTRIC HEATER SIZE B-Series 05 = 5.0 KW 10= 10.0 KW 15 = 15.0 KW 20 = 20.0 KW 25 = 25.0 KW B-Series (Btu/h) 18 = 18,000 36 = 36,000 60 = 60,000 24 = 24,000 42 = 42,000 30 = 30,000 49 = 49,000 ENGINEERING CODE OPTIONS RT = Standard Remote Operation B-SERIES CHASSIS SPECIFICATIONS MODELS: V(E,H)B18K05 V(E,H)B18K10 V(E,H)B24K05 V(E,H)B24K10 V(E,H)B30K10 V(E,H)B30K15 V(E,H)B36K10 V(E,H)B36K15 COOLING DATA: Cooling Cap. 17000 17000 22000 22000 30000 30000 35000 35000 Cooling Power (W) 1700 1700 2200 2200 2900 2900 3500 3500 SEER 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 Cooling SHR 0.78 0.78 0.75 0.75 0.70 0.70 0.70 0.70 ELECTRICAL HEAT DATA: Heater Size (KW) 5.0 10.0 5.0 10.0 10.0 15.0 10.0 15.0 Heating Cap. (Btu/h) 17050 34100 17050 34100 34100 51150 34100 51150 Heating Power (W) 5000 10000 5000 10000 10000 15000 10000 15000 Heating Current (A) 20.8 41.6 20.8 41.6 41.6 62.4 41.6 62.4 HEAT PUMP DATA: Heating Cap. (Btu/h) 17000 17000 22000 22000 30000 30000 34000 34000 Heating Power (W) 1650 1650 2000 2000 2600 2600 3300 3300 Heating Current (A) 7.3 7.3 9.3 9.3 12.0 12.0 15.0 15.0 COP 3.0 3.0 3.2 3.2 3.2 3.2 3.0 3.0 ELECTRICAL DATA: Voltage (V) 230/208 230/208 230/208 230/208 230/208 230/208 230/208 230/208 LRA - Comp. (A) 42.5 42.5 56.0 56.0 72.5 72.5 88.0 88.0 Min. Ckt. Amps (A)+ (14) 26 (14) 52 (16.7) 26 (16.7) 52 (22.8)52 (22.8)26,52 (27.9)52 (27.9) 26,52 Power Connection Hard Wire Hard Wire Hard Wire Hard Wire Hard Wire Hard Wire Hard Wire Hard Wire PHYSICAL DATA: Unit Width (in.) 30.00 30.00 30.00 30.00 30.00 30.00 30.00 30.00 Unit Depth (in.) 21.00 21.00 21.00 21.00 21....
Ce manuel est également adapté pour les modèles :Climatiseurs - 000 (516.44 kb)
Climatiseurs - 24 (516.44 kb)
Climatiseurs - 30 (516.44 kb)
Climatiseurs - 36 (516.44 kb)