|
Facilité d'utilisation
..12 15 10 20 1 .C Water Out Temp for WL1 Heating (WL1-Floor) Point . ..21 40 17 55 1 .C Point . ..22 25 17 55 1 .C Water Out Temp for WL2 Heating (WL2-Fan Coil Unit) Point . ..31 50 17 55 1 .C Point . ..32 35 17 55 1 .C Heating Water Law for Auto Mode WL Type ..41 1(WL1) 1 2(WL2) - - Outdoor Temp for Water Law (Cooling) Point . ..51 30 25 35 1 .C Point . ..52 40 35 45 1 .C Water Out Temp for WL1 Cooling (WL1-Floor) Point . ..61 25 18 25 1 .C Point . ..62 18 5 18 1 .C Water Out Temp for WL2 Cooling (WL2-Fan Coil Unit) Point . ..71 18 18 25 1 .C Point . ..72 5 5 18 1 .C Cooling Water Law WL Type ..81 1(WL1) 1 2(WL2) - - External Thermostat Application #1(Floor) ..91 0(No) 0 1(Yes) - - #2(FCU) ..92 0(No) 0 1(Yes) - - Water Law for Heating • Outdoor air temperature range : Lower limit .(#2011, Default -10.C, Range : -20 ~ 5.C), Upper limit .(#2012, Default 15.C, Range : 10 ~ 20.C) - With this default settings, the water outlet temperature by heating water law can be changed within the outdoor temperature range of -10 ~ 15.C. • Water out temperature range for floor/FCU applications respectively : Upper limit .(#2021/2031, Default 40/50.C, Range : 17 ~ 55.C), Lower limit .(#2022/2032, Default 25/35.C, Range : 17 ~ 55.C) - With this default settings, the water outlet temperature by heating water law can be changed within the range of 25/35 ~ 40/50.C. • Type of water law for according to heating devices(floor/FCU) : #2041(Default “1”(WL1 for floor)), “2”(WL2 for FCU or radiator) • The #2 DIP switch in the wired remote controller should be set to “OFF”(Default) to control the water outlet temperature. • The operation mode of the wired remote controller should be set to “AUTO”() to use the weather dependent water law scheme. Operating advanced function FIELD SETTING MODE Water Law for Cooling • Outdoor air temperature range : Lower limit .(#2051, Default 30.C, Range : 25 ~ 35.C), Upper limit .(#2052, Default 40.C, Range : 35 ~ 45.C) - With this default settings, the water outlet temperature by cooling water law can be changed within the outdoor temperature range of 30 ~ 40.C. • Water out temperature range for floor/FCU applications respectively : Upper limit .(#2061/2071, Default 25/18.C, Range : 18 ~ 25.C), Lower limit .(#2062/2072, Default 18/5.C, Range : 5 ~ 18.C) - With this default settings, the water outlet temperature by cooling water law can be changed within the range of 18/5 ~ 25/18.C. • Type of water law for according to cooling devices(floor/FCU) : #2081(Default “1”(WL1 for floor), “2”(WL2 for FCU or radiator) • The #1 DIP switch in the wired remote controller should be set to “OFF”(Default) for cooling operation of heat pump. • The #2 DIP switch in the wired remote controller should be set to “OFF”(Default) to control the water outlet temperature. • Only heating WL operation could be used through “Auto” mode of wired remote controller. External Room Thermostat (Field Option) • Terminal #1(#2091, Default “0” for no usage), #2(#2092, Default “0” for no usage) - To use wired remote controller for heating/cooling operation, both of the above settings should be set to “0” simultaneously. If not, thermostat controls system. - Types of water law used by room thermostat operation will follow the FSV settings defined in #2041(heating) and #2081(cooling) respectively. - During the thermostat operation, the user has the possibility to shift up or down the target water temperature within the range of -5 ~ +5.C. • When the remote controller is used, floor valve should be connected to zone #1 and the FCU valve should be separately connected to zone #2 of the Hydro Unit PBA. • When only floor cooling/heating is installed and if the Water Law or outlet water temperature is too low, 2way valve may closed and E911 error may occur. • When the floor and FCU units are installed together and operating in cooling mode, floor valve may close and E911 may occur to prevent floor condensation when the outlet water temperature is below 16°C. Therefore FCU should secure minimum value for the flow rate. • Thermostat #2 which controls FCU has the priority for operation modes and the discharge water temperature. • Samsung is not responsible for the accidents such as floor condensations which can occur by not connecting the valve to the zone #1 port of the Hydro Unit PBA. DHW Heating : Code 30.. T(C) TU > THP MAXTHP MAXTHP OFFTHP ONTU#3021#3022#3023T(C) TU < THP MAXTHP MAXTU=THP OFFTHP ON#3021#3023 Tu : User set temp. T(C) : Temp. (Celcius) 1 t 0 1 0 1 0 Space heating request DHW request DHW operation #3024 Space heating operation #3025 #3026 Operating advanced function FIELD SETTING MODE Field Setting Value Main Menu & Code Sub Menu Function Description Sub Code Default Min Max Step Unit DHW Code 30.. Domestic Hot Water Tank Application ..11 0(No) 0 1(Yes) - - Heat Pump Max Temp ..21 50 45 55 1 .C Stop ..22 2 2 10 1 .C Start ..23 5 1 20 1 .C Min. Space heating operation time ..24 5 0 20 1 min Max. DHW operation time ..25 30 5 95 5 min...
Ce manuel est également adapté pour les modèles :Climatiseurs - AEN160YDGHA (5.28 mb)
Climatiseurs - AEN160YDEHA (5.28 mb)
Climatiseurs - AEN080YDEHA (5.28 mb)