Log:
Évaluations - 3, GPA: 4.3 ( )

Instructions Samsung, Modèle AEN160YDGHA

Fabricant : Samsung
Taille : 5.28 mb
Nom Fichier :
Langue d'enseignement:
Aller à la télécharger



Par ce dispositif a également d'autres instructions :

Facilité d'utilisation


T(C) : Temp. (Celcius) 1 t 0 1 0 1 0 Space heating request DHW request DHW operation #3024 Space heating operation #3025 #3026 Operating advanced function FIELD SETTING MODE Field Setting Value Main Menu & Code Sub Menu Function Description Sub Code Default Min Max Step Unit DHW Code 30.. Domestic Hot Water Tank Application ..11 0(No) 0 1(Yes) - - Heat Pump Max Temp ..21 50 45 55 1 .C Stop ..22 2 2 10 1 .C Start ..23 5 1 20 1 .C Min. Space heating operation time ..24 5 0 20 1 min Max. DHW operation time ..25 30 5 95 5 min Max. Space heating operation time ..26 3 0 10 0.5 hour Booster Heater Application ..31 1(On) 0(OFF) 1 - - Delay Time ..32 20 20 95 5 min Overshoot ..33 0 0 4 1 .C Compensation Temp ..34 10 0 20 1 .C Disinfection Application ..41 1(On) 0(OFF) 1 - - Interval ..42 Fri Mon Sun 1(All) day Start Time ..43 23 0 23 1 o'clock Target Temp ..44 70 40 70 5 .C Duration ..45 10 5 60 5 min Power DHW by User Input Timer OFF Function ..51 0(Off) 0 1(On) - - Timer Duration ..52 60 30 300 10 min Solar Panel H/P Combination ..61 0 0 1(Yes) - - Direction of DHW valve DHW Tank ..71 0(Room) 0 1(Tank) - - DHW Application The FSV #3011 in the wired remote controller should be set to “1(Yes)” to use DHW function. Heat Pump Variables for Controlling DHW Tank • Maximum DHW tank temperature with R410A(refrigerant) heat pump operation : FSV #3021, Default 50.C, Range : 45 ~ 55.C. • Temperature difference determining the heat pump OFF temperature : FSV #3022, Default 2.C, Range : 2 ~ 10.C. • Temperature difference determining the heat pump ON temperature : FSV #3023, Default 5.C, Range : 1 ~ 20.C. • DHW heating mode timer : Mode timer manage the operation terms when there are simultaneous requests of space heating/cooling and DHW. - FSV #3024(minimum Space heating operating time, Default 5 min., Range 0 ~ 20 min.), #3025(maximum DHW time, Default 30 min., Range 5 ~ 95 min.), #3026(maximum space heating operation time, Default 3 hour, Range 0 ~ 10 hour) - Maximum operation time is applied only when both DHW and Space heating request operation. DHW or Space heating operates continuously until reaching at target temperature without time limitation in the single operation. The FSV #4011 for DHW priority should be set to “0(DHW)”(Default). Space heating gets a priority by setting FSV #4011 “1”, but this is only valid when the outdoor temperature is lower than the specified temperature defined by FSV #4012. t101010DHWrequestH/PoperationBoosteroperation#3032#302510Heatingrequest tHPBHHPTBH OFFTHP MAXTHP OFFTHP ONTBH ONTU#3023#3022#3033 t00.0001.0022.0023.0024.00#3044#3043#3045TUTH Operating advanced function FIELD SETTING MODE Booster Heater Variables for Controlling DHW Tank • The FSV #3031 should be set to “1(On)”(Default) to use booster heater as an additional heat source for DHW tank. • Booster heater startup delay timer : In case of DHW request, this timer will delay the operation of booster...

Ce manuel est également adapté pour les modèles :
Climatiseurs - AEX060EDEHA/EU (5.28 mb)
Climatiseurs - AEN160YDEHA (5.28 mb)
Climatiseurs - AEN080YDEHA (5.28 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories