Log:
Évaluations - 0, GPA: 0 ( )

Instructions LG, Modèle URNU76GB8Z2.ENWALEU

Fabricant : LG
Taille : 2.21 mb
Nom Fichier :
Langue d'enseignement: ruitenesfrdenlpt
Aller à la télécharger



Facilité d'utilisation


ON/OFF button 5. Opration mode selection button 6. Wireless remote controller receiver • Some products don't receive the wireless signals. 7. Air flow button 8. Subfunction button 9. Function setting button 10. Ventilation button 11. Reservation 12. Up,down,left,right button • To check the indoor temperature, press button. 13. Room temperature button • Displays only the room temperature of the remote controller perception. • There is no control of room temperature. • In case of fresh air intake unit, displays only the temperature around remote controller. 14. Setting/Cancel button 15. Exit button . Some functions may not be operated and displayed depending on the product type. . It will display strange value to the room temperature if wired remote controller is not connected. Model : PQRCVSL0 (Black Color) PQRCVSL0QW (White Color) Owner.s Manual 7 Operating Instructions Name and function of wired remote controller(Accessory) PQWRCDF0 (Heat pump) PQWRHDF0 (Cooling only) 13 14 15 16 1 8 9 10 11 12 2 3 4 5 6 7 Cooling Mode Auto Mode or Auto Changeover Dehumidification mode Heating Mode Fan Mode • Cooling Model( ), Heat Pump Model( ) Operation Mode 1. Plasma button (optional) Used to start or stop the plasma-purification function. 2. Jet cool button Speed cooling operates super high fan speed. 3. Operation mode selection button Used to select the operation mode. 4. Function setting button Used to set or clear auto clean or smart clean. 5. LCD luminosity button (optional) Used to adjust LCD luminosity 6. Smart clean button (optional) Used to start or stop smart clean. 7. Clear all button Used to clear all timer. 8. Room temperature setting button Used to select the setting outlet temperature 9. ON/OFF button Used to turn off/on the unit. 10. Indoor fan speed selection button Fan speed in all step is same 11. Auto swing button Used to stop or start louver movement and set the desired up/down airflow direction. 12. Horizontal airflow direction control button (optional) Used to set the desired horizontal airflow direction. 13. Timer and time setting button Used to set the time of starting or stopping and sleeping operation. 14. Room temperature checking button • Used to check the room temperature. • Displays only the room temperature of the remote controller perception. There is no control of room temperature. 15. .C/.F switch button Used to switch temperature reading from Celsius to Fahrenheit. 16. Reset button Used to reset the remote controller. 8 Fresh Air Intake Unit Operation Details Operation Details Operation range ENGLISH FAU will operate in the below range. Hot outdoor temperature (over 43.) or cold outdoor temperature (under 5.) will make customer feel uncomfortable because FAU outlet temperature might be not enough controlled in that region. * FAU : Fresh Air Intake Unit Outdoor Air Temperature (Toa) . -5°C 5°C 15°C 19°C 43. (1) Cooling mode Heating mode Automatic mode Fan stop Fan operation (thermo off) Cooling Fan operation 6°C 18°C Cooling Heating Fan operation (thermo off) Heating 16°C Fan operation Heating Cooling Heating 16°C 18°C Cooling (1)Normal model : 43°C Tropical model : 48°C Usage Limitations -5°C 15°C 19°C (33.5°) 43. (2) (2)Normal model : 43°C Tropical model : 48°C Owner.s Manual 9 Maintenance and Service Maintenance and Service CAUTION: Before performing any maintenance, turn off the main power to the system. Grille, Case, and Remote Controller . Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives. NOTICE Power supply must be disconnected before cleaning the indoor unit. Air filter The air filters behind the front grille should be checked and cleaned once every 2 weeks or more often if neccessary. ¦ Never use any of the followings: • Water hotter than 40°C. Could cause deformation and/or discoloration. • Volatile substances. Could damage the surfaces of the air conditioner. Air outlet vent Air filter 1. Remove the Air filter. ¦ Take hold of the tab and pull slightly forward to remove the filter. CAUTION: When the air filter is to be removed, do not touch the metal parts of the indoor unit. It may cause an injury. 2. Clean dirt from the air filter using a vacuum cleaner or washing with water. ¦ If dirt is conspicuous, wash with a neutral detergent in lukewarm water. ¦ If hot water (50°C or more) is used, it may be deformed. 3. After washing with water, dry well in the shade. ¦ Do not expose the air filter to direct sunlight or heat from a fire when drying it. 4. Install the air filter. 10 Fresh Air Intake Unit Maintenance and Service When the air conditioner is not going to be used for a long time. ENGLISH Operation Tips Helpful information The air filters and your electiric bill. If the air filters become clogged with dust, the cooling capacity will drop, and 6% of the electricity used to operate the air conditioner will be wasted. When it is not going to be used for a long time. When the air conditioner is used again. Operate the ...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories