Log:
Trier : Nom ↑   Téléchargements   Évaluation   Taille ↑  
Téléchargements : 6   Taille : 4 mb   Fabricant : Admiral  
Catégorie : Climatiseurs
@name@name

Keep this manual for future reference. Muchase gracias por comprar un aire acondicionado Admiral®. Lea atentamente el “Manual de Uso y Mantenimiento” antes de instalar y utilizar este producto. Conserve este manual para consultarlo en el futuro. For Service Call 1 877 465 3566 Para obtener servicio tecnico, llame al 1 877 465 3566 ROOM AIR CONDITIONER Use and Care Manual AIRE ACONDICIONADO PARA HABITACIONES Manual de Uso y Mantenimiento WAC 5 6 8 USER MAN final 3/2/05 12:23 PM Page 1 WAC 5 6 8 U

Téléchargements : 11   Taille : 5 mb   Fabricant : Admiral  
Catégorie : Climatiseurs
@name@name

However, the fan motor will continue to operate after the compressor (cooling cycle) is completed. Fresh Air Ventilation is usually kept in the closed position. Use only when clearing smoke and/or odors from the room. Pull to open. p g Fig. 15 Mechanical control model Thermostat knob Mode knob Fig. 16 Fresh Air Vent Lever F H R FAN SPEED MODEOFFON/ TIMER Airconditioner WAIT THREE MINUTES BEFORE RESTARTING LOW FAN MED FAN HIGH FAN OFF HIGH COOL MED COOL LOW COOL 1 3 5 7 9 CO LER O 1 3 13 OPERATIN

Téléchargements : 9   Taille : 4 mb   Fabricant : Admiral  
Catégorie : Climatiseurs
@name@name

. . . . . .14 I.NDICE Page Introduccion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Identificacion de las Piezas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Especificaciones Electricas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Consejos Antes dela Instalacion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Instrucciones de Instalacion . . . . . . . . . .

Téléchargements : 8   Taille : 6 mb   Fabricant : Admiral  
Catégorie : Climatiseurs
@name@name

More frequent cleaning may be necessary depending on outdoor and indoor air quality. 3. Use drapes, curtains, or shades to keep direct sunlight from heating your room, but DO NOT obstruct the air conditioner. Allow air to circulate around the unit without obstructions. 4. Start your air conditioner before outdoor air becomes hot/cold and uncomfortable. This avoids an initial period of discomfort while the unit is cooling or heating off the room. 5. When outdoor temperature is cool enough, use HI

Téléchargements : 7   Taille : 4 mb   Fabricant : Admiral  
Catégorie : Climatiseurs
@name@name

Maximum air circulation and cooling occur when in the closed position. ON/OFF button The air conditioner will be started when it is energized or will be stopped when it is in operation, if you press this button. MODE button Each time MODE button is pressed, the operation mode is changed in sequence: COOLING FAN ONLY ENERGY SAVING COOLING NOTE: After setting the mode, allow 3 minutes before switching to another mode. FAN SPEED button Used to select fan speed in sequence auto, low, medium and high

Téléchargements : 10   Taille : 4 mb   Fabricant : Admiral  
Catégorie : Climatiseurs
@name@name

When outdoor temperature is approximately 65 F or below, frost may form when unit is in cooling mode. Switch unit to FAN (only) operation until frost melts. Remove and clean filter. PROBLEM POSSIBLE CAUSE SUGGESTED SOLUTION Air conditioner will not operate Inefficient or no cooling Noisy unit Odors Water dripping outside Water dripping inside Ice or frost build-up Low outside temperature. Unit air filter is dirty. Unit is not properly angled to allow water to drain outside. Unit must be installe

Téléchargements : 12   Taille : 6 mb   Fabricant : Admiral  
Catégorie : Climatiseurs
@name@name

If the leveling screws are distanced too far away from the wall to provide stability, it may be necessary for you to fill this area with a solid piece of wood. See (Fig. 8). Fig. 5 Bracket Assembly Bracket Bolts Leveling Screw V-slot 90 Angle Support Brackets (TOP VIEW) Center Window sill V-slot (2) 3/4" screws per bracket Bracket Assembly Leveling Screw Outer Wall Construction 3/16" Maximum B. Measure the inside window sill width and find the center as shown in (Fig. 6). Align the V-slot in eac

Téléchargements : 6   Taille : 3 mb   Fabricant : Admiral  
Catégorie : Climatiseurs
@name@name

The air filter should be cleaned once a month. More frequent cleaning may be necessary depending on outdoor and indoor air quality. Air Filter Removal The air filter on the above models is located behind the Air Inlet Grille. To remove the air filter, grasp the filter handle located on the up side of the Air Inlet Grille and elide the air filter to the up. To reinstall the air filter, reverse the above procedure. ik CAUTION ik DO NOT forget to install the air filter. If the air conditioner

Téléchargements : 5   Taille : 6 mb   Fabricant : Admiral  
Catégorie : Climatiseurs
@name@name

If you press Timer button within the 12 seconds, OFF Timer will be canceled. If the ON Timer is set, the timer LED displays the remaining time to turn on the unit. If you want to cancel ON TIMER, press Timer button. Used to set room temperature in COOLING mode or used to set time in Timer mode. If the two keys are pressed at the same time ,the temperature LED display will alternate between and . button The air conditioner will be started when it is energized or will be stopped when it is in oper

Téléchargements : 7   Taille : 6 mb   Fabricant : Admiral  
Catégorie : Climatiseurs
@name@name

When the air conditioner is heating, allow 3 minutes after you press this button. NOTE: After setting the mode, allow 3 minutes before switching to another mode. In the FAN ONLY Mode, Room Temperature display range is from 0 (32 ) to 38 (99 ). Room Temperature below 32 ,the Temperature display L0. Room Temperature above 99 ,the Temperature display H1. Operating Instructions Remote control 1 2 3 4 7 Power Mode +_ Temp/Time Auto Power Saver Mid High Low Timer Fan Speed 1 2 3 8 5 6 84 5 6 7 9 9 Pow





catégories