Facilité d'utilisation
5-1 TROUBLESHOOTING To determine the cause of any malfunction: 1. Determine the problem (e.g., the food isn't staying hot). 2. Locate the problem in the Troubleshooting table. 3. Read through the possible causes ,then try each solution listed until the problem is resolved. . 4. If you are unable to locate the problem in the table or if the solutions listed don't work, please call the BEVLES manufacturing facilities for assistance at (800) 441-1601. You will need to provide the factory personnel with the following information: 1. The product model and serial numbers. 2. The specific nature of the problem. In some cases it will be beneficial to also have the actual operator of the equipment available to answer questions. 5-2 TROUBLESHOOTING TABLE Problem Possible Cause Solution 1. Unit will not heat. Power switch not in on position. Place the power switch in the ON position. Loose or unplugged power cord. Plug power cord into proper electrical outlet. Thermostat on wrong setting. Set thermostat to correct temperature. Faulty thermostat (not switching heating element on when below set temperature). Replace thermostat per section 61i or j. Faulty internal wiring. Check connections for heating module components per sections 6-11. Faulty heating element (not getting hot). Replace heating element per section 6-11. Hi-temperature safety thermostat on. Check for failure of heating element and/or thermostat not shutting down. 2. Unit not reaching or holding desired Temperature uniformly. Doors left open or ajar. Close doors firmly and keep closed except. when loading or unloading product. Thermostat on wrong setting. Set thermostat to correct temperature. Faulty thermostat (not switching heating element on when below set temperature). Replace thermostat per section 6-1i or j. Faulty internal wiring. Check connections for heating module components per section 611 Top mounted heating module seal (gasket) torn or worn. Replace gasket per section 6-1 m. Faulty heater fan blower (no air circulating). Replace fan blower motor per section 6-1k. 3. Unit overheating. Faulty thermostat (not switching heating element off when above set temperature). Replace thermostat per section 6-1i or j. 4. Fan blowers not operating. Power switch not in on position. Place the power switch in the on position. Loose or unplugged power cord. Plug power cord into proper electrical outlet. Faulty heater fan blower. Replace fan blower motor per section 6-1k. Faulty internal wiring. Check connections for heating module components per sections 6-11. 5. Cabinet steamy and too humid. Too much humidity in air flow. Adjust baffles per section 3-2. Holding temperature not high enough. Adjust thermostat to a higher temperature level. Holding product too long in cabinet. Minimize holding time. 6. Cabinet too dry. Water pan dry. Fill 3/4 full with water. Not enough humidity in air flow. Adjust baffles per section 3-2. Holding temperature too high. Adjust thermostat to a lower temperature (never below 140°F). . 6. MAINTENANCE **CAUTION: All maintenance on BEVLES Heating Holding Cabinets should be performed by trained personnel using only quality BEVLES parts. 6-. REPLACIN. PART. Afte. usin. th. Troubleshootin. tabl. (sectio. 5-2. t. determin. th. solution. refe. t. th. appropriat. sectio. below. Th. tool. an. equipmen. neede. fo. eac. repIacemen. procedur. ar. liste. a. th. beginnin. o. tha. procedure. 6-1a. Removing the top mounted heating module. Required: No tools required 1. Unplug unit from power source. 2. Open top front door and remove water pan and baffles. 3. Using two people, lift the top mounted heating module straight up and off of the cabinet (Fig 8) . 4. Set module upside down on a heat resistant surface. 6-1b. Removing the front panel from the heating module. Required: Medium (6') phillips screwdriver, Medium (6') flathead screwdriver 1. Remove all five screws from the face of the front panel (at the four corners and center top). 2. Gently lift off the front panel while guiding attached wires and thermometer probe to prevent damage. (Fig. 9) 3. Leaving wires...
Ce manuel est également adapté pour les modèles :Meubles - CA43-CV7 or CV13 (1.57 mb)
Meubles - CA43-CV9 (1.57 mb)
Meubles - CA70-CV16 or CV32 (1.57 mb)
Meubles - Convection Heated Holding Cabinet CA34-CV9 (1.57 mb)