Instructions Firex, Modèle 591S

Fabricant : Firex
Taille : 167.7 kb
Nom Fichier : 1501991.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


The remote accessory is available with either the single gang remote indicator/control (591 models), or with the addition of a single gang strobe assembly (592 models). Both versions are compatible with standard Decora style cover plates (choice of white, red or stainless steel). A strobe-only version (593 models) is available for retrofit upgrade of “controller only” installations. The indicator/control assembly provides: . Visual indication of detector Pilot, Trouble and Alarm Functions . Selectable audible indication of Alarm, Trouble or both . Buzzer Silence function, with silenced indication and “ringback” following condition correction . Lamp/Buzzer test function . Key-Operated detector Test and Reset functions . Lever-operated “No-Tools” terminal block . Port for plugging in the optional strobe assembly . Black “DUCT SMOKE DETECTOR” decal included for front plate . Blue “SMOKE”, red “FIRE” strobe lens decals included for both horizontal and vertical mounting Strobe Connection The strobe assembly provides visual indication of alarm conditions, and is connected to the indicator/control assembly via the provided polarized connector. To install the strobe module, simply plug the provided connector onto the pins as indicated on the rear of the indicator/control module. Snap the strobe lens into the cover plate, and install cover plate following completion of remote module wiring. NOTE: The strobe and audible buzzer features are not ADA compliant, and not intended for life safety notification or evacuation purposes (public mode). These functions are for duct smoke detector status indication only (private mode). Duct Smoke Detector Remote Accessories Universal Voltage Models Compatible with 230 VAC, 115 VAC, 24 VAC or 24 VDC operation 2650-760 Ionization • 2650-761 Photoelectric 2650-660 Ionization • 2650-661 Photoelectric 2650-560 Ionization • 2650-561 Photoelectric 591S 592SC Audible Buzzer Configuration There are two jumpers located on the rear of the indicator/control assembly. To enable audible buzzer operation for Alarm or Trouble conditions, simply leave the jumpers in place. To disable either or both functions, remove the appropriate jumper(s). TBL ALM TBL ALM TBL ALM TBL ALM Buzzer will Buzzer will Buzzer will Buzzer function on function on function will not both Alarm on Alarm on Trouble function and Trouble Condition Condition on Alarm Conditions only only or Trouble Conditions Silence and Ringback Functions On the occasion where an audible alarm or trouble condition needs to be silenced while the detector condition is inspected and remedied, the indicator/control module provides a silence function. The slide switch located on the front of the module is pushed DOWN to activate the silence function. Upon correction of the notified condition, the silenced buzzer will resume sounding. The ringback feature serves as a reminder to reset the silence switch to the “normal”, UP position. Normal “Standby” Silenced Mode Note that the strobe module, when installed, will not stop operating when the silence function is engaged. Mode Wiring Fo...

Ce manuel est également adapté pour les modèles :
Alarme incendie - 592SC (167.7 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories