Log:
Évaluations - 2, GPA: 4.5 ( )

Instructions Firex, Modèle 592SC

Fabricant : Firex
Taille : 167.7 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Normal “Standby” Silenced Mode Note that the strobe module, when installed, will not stop operating when the silence function is engaged. Mode Wiring For appropriate duct detector wiring terminals, please refer to detector and remote accessory installation instructions. Products 591 Series Remote Accessory Controllers 591W Remote Indicator/Control Assembly w/White Single Gang Cover Plate 591R Remote Indicator/Control Assembly w/Red Single Gang Cover Plate 591S Remote Indicator/Control Assembly w/Stainless Steel Single Gang Cover Plate 592 Series Remote Accessory Controllers with Strobe 592WC Remote Indicator/Control Assembly w/Strobe Assembly (Clear Lens); White Double Gang Cover Plate 592WO Remote Indicator/Control Assembly w/Strobe Assembly (Opaque Lens); White Double Gang Cover Plate 592RC Remote Indicator/Control Assembly w/Strobe Assembly (Clear Lens); Red Double Gang Cover Plate 592RO Remote Indicator/Control Assembly w/Strobe Assembly (Opaque Lens); Red Double Gang Cover Plate 592SC Remote Indicator/Control Assembly w/Strobe Assembly (Clear Lens); Stainless Steel Double Gang Cover Plate 592SO Remote Indicator/Control Assembly w/Strobe Assembly (Opaque Lens); Stainless Steel Double Gang Cover Plate 593 Series Remote Accessory Strobes (as an optional field upgrade kit for existing installed 591 Series Controllers) 593RC Strobe Assembly (Clear Lens); Red Double Gang Cover Plate 593RO Strobe Assembly (Opaque Lens); Red Double Gang Cover Plate 593SC Strobe Assembly (Clear Lens); Stainless Steel Double Gang Cover Plate 593SO Strobe Assembly (Opaque Lens); Stainless Steel Double Gang Cover Plate 593WC Strobe Assembly (Clear Lens); White Double Gang Cover Plate 593WO Strobe Assembly (Opaque Lens); White Double Gang Cover Plate Power Requirements: Standby 13mA Dimensions: Single Gang Plate: Alarm LED Trouble with Buzzer Trouble Silenced Trouble without Buzzer Alarm with Buzzer 22mA 33mA 33mA 13mA 37mA 4-1/2” (114.3 mm) H x 2-3/4” (69.85 mm) W Double Gang Plate: 4-1/2” (114.3 mm) H x 4-1/2” Alarm Silenced with Buzzer 37mA (114.33 mm) W Alarm with Buzzer and Strobe Alarm Silenced with Buzzer and Strobe 154mA 157mA Wiring: 14-28 AWG. Solid or Stranded Lamp Test with Buzzer 62mA Approvals: U.L. Listed for use with Firex duct Lamp Test with Buzzer Silenced 52mA smoke detectors including all 2650 Sound Pressure: 60db @ 10 ft. Series duct smoke detectors UL URRQ, URRQ7.S7425 / CSFM / MEA Controls Americas 515 South Promenade Avenue 3505 Laird Road Unit #14 Technical Service US Corona California 92879-1736 USA Mississauga Ontario L5L 5Y7 Canada Telephone +1 800 445 8299 Cust. Svc. Telephone +1 800 951 5526 Cust. Svc. Telephone +1 800 387 7978 Facsimile +1 630 260 723 LISTED MEA ACCEPTED Cust. Svc. Facsimile +1 630 260 7299 Cust. Svc. Facsimile +1 905 828 1265 technicalservice@invensys.com 268A Listed iccacustomerservice@invensys.com iccacustomerservice@invensys.com R THREE YEAR WARRANTY STATEOF CALIFORNIA STATEFIRE MARSHAL LISTINGSERVICE © 2006 Invensys Controls Americas 6/06 - #150-1991 ...

Ce manuel est également adapté pour les modèles :
Alarme incendie - 591S (167.7 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories