Instructions Firex, Modèle 45189

Fabricant : Firex
Taille : 472.37 kb
Nom Fichier : 45189_1501714Sellsh.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


The alarm shall have a "quick connect" molded harness. The alarm shall have a dual chamber ionization sensor. The alarm shall be rated at no greater than 0.5W in standby. Nominal sensitivity shall be measured by U.L. at 1.29 ± 0.51% obs./ft. Temperature operating range shall be between 40° and 100°F; humidity range between 10%-93% relative humidity; 100% solid state alarm circuits over an input range of 100-130V AC. A green continuous power-on indicator shall be a built-in light emitting diode when AC power is present; a second red blinking LED shall indicate that a sufficient 9-volt battery back-up is present; when activated the initiating alarm red LED shall flash while the interconnected alarm LEDs remain extinguished. The Quick Quiet™ False Alarm Control™ feature shall desensitize the alarm for 15 minutes. The red LED shall blink once every 10 seconds when in Quick Quiet™ False Alarm Control™ and the alarm shall produce two short chirps 2 seconds apart at the conclusion of the desensitized period. The test switch shall electronically activate the chamber to simulate smoke and check for proper operation. The Piezoelectric horn shall have a level of 85 decibels at 10 feet. The alarm shall mount to a single gang box, 4" octagon junction box, or a square to round drywall ring without screw removal. It shall have a pigtail wiring, and a separate mounting bracket. It shall include a battery "lock-out" to prohibit mounting if battery is not installed and a tamper-resistant locking pin to prevent unauthorized removal. The 45189 shall meet the requirements of U.L. Standard 217. §5, C Year yff') Limited CiS? Warranty description The Firex 45189 Smoke Alarm is an ionization120V AC smoke alarm with a lithium battery back-up providing enhanced battery life for single or multiple station use. It includes a Quick Quiet™ False Alarm Control™ feature which allows the user to quiet an unwanted alarm for up to 15 minutes. The 45189 has an 85 decibel horn, test switch and separate lighted power and alarm LED indicators; the green "power on" LED confirms constant AC power and the red LED displays alarm/battery status. The 45189 is interconnectable with up to 11 other AC/DC smoke alarms and 6 Firex heat, carbon monoxide or smoke and co combo alarms for a total of not more than 18 Firex devices. technical information Item/Model_45189 / ADC Product Weight 8 ounces Operating Temp. 40° to 100°F 4° to 38°C Interconnect Qty. Up to 18 Firex devices maximum: 12 Smoke alarm items 4418 (model AD), 4518 (model ADC), 5000 and 4618 (model FADC), and 4480 (model PAD). Up to 6 heat, CO or smoke/CO combo alarms maximum; heat alarm item 5700 (model ADH), CO alarm item 6045 (model COQ8) or smoke/CO combo alarm 7000(C) (model FADCQ). Electrical Rating 120V AC, 60HZ, 50mA max, 9 Volt Lithium Battery Back-up Alarm Point 1.29±0.51%/ft. obscuration Horn Output 85 decibels at 10 feet Listing UL 217 Detection Type Dual Ionization Chamber Humidity Range 10% to 93% Relative Humidity shipping specifications Individual Carton Dim._5-1/8" x 5-1/8" x 1-1/2" 13cm x 13cm x 3.8cm Master Carton Quantity 24 Master Carton Dimensions 19-3/4" x 10-3/4" x 5-1/2" 50.2cm x 27.3cm x 13.9cm Master Carton Weight 13 lbs 5.9 kq Pallet Quantity 1152 Pallet Dimensions 40"L x 48"W x 48"D 102cm x 122cm x 122cm Mounting Bracket Side View An ISO 9002 Certified Company Invensys Climate Controls Americas 191 E. North Avenue Carol Stream, IL 60188 USA Cust. Service Telephone +1 800 951 5526 Cust. Service Facsimile +1 630 260 7299 150-1714...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories