Facilité d'utilisation


Replace Water Inlet Valve if needed. See ”Water Inlet Valve Test” B Inoperative Dispense Switch Check Switch connections. Replace Dispense Switch if needed. C Inoperative Rinse Switch Check Rinse Switch connections. Replace Rinse Switch if inoperative. 4 Water does not shut off. Water keeps dispensing. D Clogged/stuck Water Dispense Valve Clean or unclog Water Dispense Valve. Replace Dispense Valve if inoperative. A Heater Switch is OFF. Turn Heater Switch ON. B Thermostat is OFF. Turn Thermostat ON. Turn Knob Clockwise. C Loose connection on Thermostat. Make sure all wires and terminals on Thermostat are tight. D Hi-Limit Temperature Switch is defective Replace the Hi-limit. 5 Water is not heating up in the tank. E Heater is burned out or defective. Replace the Heater. TROUBLESHOOTING GUIDE WARNING: To reduce the risk of electrical shock unplug the dispenser power cord before repairing or replacing any internal components of the unit.. Before any attempt to replace a component be sure to check all electrical connections for proper contact. PROBLEM PROBABLE CAUSE REMEDY A Dispensing unit unplugged Reconnect dispensing unit B No power from Terminal Block Check the Terminal Block for loose wire C Defective Bulb Replace Bulb. D Defective Ballast. Replace Ballast. 1 Light Display not lit. No power. E Loose Bulb in socket. Make sure bulb is seated properly in socket. A Water supply OFF. Turn water ON. B Clogged inlet screen (Water Inlet Valve). Disconnect water line and clean inlet screen. C Inoperative Water Inlet Valve. Check connection, if needed replace Valve. 2 No water when Rinse Switch is ON. D Loose electrical connection. Check all electrical connections. A No product in Hopper. Add product. B Auger not working. Engage Hopper/Nut to Motor Gear (See section VI). C Damaged, loose, or missing Agitator Gear. Replace Agitator/Auger Gear (See section VI). D Inoperative Auger Motor or Relay. Check connections of Motor, Relay and/or Switch, if needed replace components. E Hopper outlet clogged Clean Hopper and check Cartridge Heater. 3 No product when Dispense Button is pressed F Faulty Coupling. Replace damaged Coupling components. A Leaking Water Inlet Valve. Clean/check fittings of Water Inlet Valve. Replace Water Inlet Valve if needed. See ”Water Inlet Valve Test” B Inoperative Dispense Switch Check Switch connections. Replace Dispense Switch if needed. C Inoperative Rinse Switch Check Rinse Switch connections. Replace Rinse Switch if inoperative. 4 Water does not shut off. Water keeps dispensing. D Clogged/stuck Water Dispense Valve Clean or unclog Water Dispense Valve. Replace Dispense Valve if inoperative. A Heater Switch is OFF. Turn Heater Switch ON. B Thermostat is OFF. Turn Thermostat ON. Turn Knob Clockwise. C Loose connection on Thermostat. Make sure all wires and terminals on Thermostat are tight. D Hi-Limit Temperature Switch is defective Replace the Hi-limit. 5 Water is not heating up in the tank. E Heater is burned out or defective. R...

Ce manuel est également adapté pour les modèles :
Autres appareils de cuisine - GB1HC-CP (547.88 kb)
Autres appareils de cuisine - GB1HC-CP-PC* (547.88 kb)
Autres appareils de cuisine - GB2-CP (547.88 kb)
Autres appareils de cuisine - GB2CP (547.88 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories