Log:
Évaluations - 4, GPA: 3.8 ( )

Instructions Oricom, Modèle Secure 100

Fabricant : Oricom
Taille : 506.34 kb
Nom Fichier : 66ac4770-3486-2f84-7134-d0360b7f00e1.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Note: Low battery alert can be suppressed by pressing any button. Charging the Battery The Parent Unit will work for up to 10 hours with fully charged batteries. If a battery low warning beep is heard and the red Power light on the Parent Unit is fl ashing, you should put the parent unit on the Charger Pod to recharge the batteries. You can still use your Parent Unit from the Charger Pod. When charging, the red power light on the charger will light steadily. When you switch on your Parent Unit, the green and red sensor lights will briefly indicate the current charge level of the batteries in the following way: 10 BASIC OPERATION 10 BASIC OPERATION 8 lights illuminated 6 lights illuminated 4 lights illuminated 2 lights illuminated (alarm beep sounds) fully charged half charged battery is running low batteries need recharging Rechargeable batteries in the Parent unit give up to 10 hours continuous usage. Please note however, that new batteries do not reach full capacity until they have been in normal use for several days. Running rechargeable batteries right down at least once a week will help them last as long as possible. The charge capacity of rechargeable batteries will reduce with time as they age, so reducing the performance time of the parent unit. Eventually they will need to be replaced. Note: The parent unit can be used on or off the charger pod. When on the charger pod, the batteries will be recharged at the same time. However, the time it takes to charge the batteries to full will be longer when the unit is charged and used at the same time. The Parent Unit can't be operated on the charging cradle without batteries. TROUBLESHOOTING TROUBLESHOOTING 11 Problem The red power lights do not turn on when you plug in the power. The green Link light on the Parent Unit is flashing and cannot hear the sounds from your baby's room. Can't hear your baby on the Parent Unit but the Link light is still glowing steadily. The Red Power light is flashing on the Parent Unit Two bars flash on the parent unit. A high pitched ear piercing noise will be heard from the units (feedback). Possible cause(s) 1. Check if the units are properly connected to the power supply. 2. Check if the power is turned on. If not, Press [ ] to turn on the power. 1. You may have moved out of range. Move closer to the Baby Unit and wait 5 seconds for the Link to establish. 2. You may need to re.establish the Link between the two units. Turn both units off by pressing and holding the [ ] and then turn on again by pressing the [ ]. Check if the volume is turned up on the Parent Unit. Your re-chargeable batteries are running low. Return the Parent Unit to the Charger Pod to recharge them. 1. The batteries in the parent unit are not fully charged. Charge the parent unit for 14 hours before use. 2. The power to the baby unit may be turned off or disconnected, and or the Baby unit may be turned off. Reconnect the AC power adaptor to the baby unit and or turn on the baby unit. 3. You may have to re-establish the link between the two units. You will need to remove the batteries from the parent unit and register the parent unit back to the baby unit by following the instructions below: A. Ensure batteries are removed from the Parent unit (and baby unit if fitted) and the AC power plug is disconnected from the Baby unit). Press and hold the [ ] on the BABY unit then plug in the AC power plug, after 2 seconds, when the baby unit night-lights flash release the [ ] button; B. Press and hold the [ ] on the PARENT unit then insert the batteries, after 2 seconds, the parent unit will sound an alert and the level indication red LED’s will flash, then release the [ ] button; C. After a few seconds, the PARENT unit will give a confirmation tone and the units will be re-linked and ready to use. NOTE: Steps A and B need to be performed within 50 secs. Check if the Parent and Baby Units are too close together. Move them further apart. 12 PRODUCT SPECIFICATIONS 12 PRODUCT SPECIFICATIONS Feature Operating Frequency Range Power supply (baby unit) Non rechargeable batteries (baby unit) (not included in the package contents) Transmitting power Power supply (parent unit) Rechargeable batteries (parent unit) (included in the package contents) Operating time with charged battery Specifications DECT 1.8 GHz Up to 300m under optimum conditions. The range is reduced in buildings (up to 50m) as a result of walls, doors etc. Input: 240 VAC 50Hz Output: 6 VDC, 200 mA, Type: AA, 1.5 V Alkaline Average: 10 mW Maximum: 250 mW Input: 240 VAC, 50Hz Output: 6 VDC, 200 mA Type: AAA, 1.2 V, 800 mAh NiMH Approx. 10 hours GUARANTEE GUARANTEE 13 Warranty (Australia) (a) Warranty Oricom International Pty Ltd (Oricom) warrants that the product is free from defects in materials and workmanship for a period of 12 months effective from the date of purchase. This warranty in no way affects your statutory warranty under the Trade Practices Act 1974 or any other similar legislation. It is import...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories