Table 3 A9891A RAID-01 Driver Versions By Release
Release
HP-UX Version
Driver Name/Version
Bundle Name
Application Release 1204
ciss B.11.11.04
Application Release 0905
ciss B.11.11.05
Application Release 0603
ciss B.11.11.06
Application Release 0606
HP-UX 11i v1 (B.11.11)
ciss B.11.11.06
RAID-01
Application Release 0609
ciss B.11.11.06
Application Release 0706
ciss B.11.11.07
Application Release 0709
ciss B.11.11.07
2 New and Changed Features in This Release
2.1 New Features
The following feature is new with version B.11.11.0709 of RAID-01:

Changing the Expand Priority
To change the expand priority of the controller to low, medium, or high, use the command:
saconfig /dev/cissX -e [low|medium|high]
Where:
cissX
The device file for the Smart Array controller.
[low|medium|high]
The priority level of the capacity expansion.
When you create a logical drive after the controller configuration was cleared, or after the
last logical drive was deleted, the expand priority of the controller will default to “medium.”
You can use saconfig with the -e option to change the expand priority.
The expand priority setting applies to both extending the capacity of a logical drive and
expanding the capacity of an array. For more information about these functions, see the HP
Smart Array 6400 Series Controller Support Guide
at:
http://docs.hp.com/en/netcom.html#Smart%20Array%20%28RAID%29
3 Problems Fixed in This Version
There are no defects or fixes included in RAID-01 at the time of this publication. See the “Related
Information”
section of this document for information on where you can find the latest information
about RAID-01 and HP Smart Array controllers.
4 Known Problems and Limitations
This section provides a list of problems and limitations as known to HP at time of publication.
If workarounds are available, they are included.

Cabling Issue
Each channel has two connectors (one internal and one external), but only one connector
can be used per channel at any given time. If the internal and external connectors on the
same channel are both connected to the storage and boot is attempted, the controller will
fail.
4


...

Ce manuel est également adapté pour les modèles :
Matériel de réseau - HP-UX 11i v1 I/O Cards (275.92 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories