|
Instructions Alliance Laundry Systems, Modèle 512685R2
Fabricant : Alliance Laundry Systems Taille : 2.19 mb Nom Fichier : 917eef4d-40a1-465e-b8e5-87f89b98551e.pdf
Langue d'enseignement:
|
|
|
|
Aller à la télécharger
Facilité d'utilisation
Use an acceptable indicating device connected to the center grounding pin of the plug and the green screw on the back of the cabinet. 10. Reinstall access cover and screw. 512685 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 21 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 22 512685 Step 5: Reverse Door, if Desired NOTE: Doors with windows cannot be reversed. The door on this dryer is completely reversible. To reverse door proceed as follows: 1. Remove four hinge attaching screws. 2. Remove all nine screws. 3. Pull bottom of door liner out, then pull down, removing door liner from door panel. 4. Rotate door panel 180 degrees as shown. 5. Remove door strike from door liner and reinstall on opposite side. 6. Insert liner under flange on bottom of door, then push top of door liner into place. 7. Reinstall nine screws removed in Step 2. Figure 20 Figure 21 Figure 22 D675I D675I D272P DRY1916N B A DRY1916N Figure 23 Figure 24 Figure 25 Figure 26 D273P DRY1917N DRY1917N DRY1918N B A DRY1918N DRY1919N DRY1919N © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 512685 23 8. Using screwdriver, remove two door plugs, and reinstall on opposite side of door opening. 9. Reinstall four hinge attaching screws, removed in Step 1. Step 6: Wipe Out Inside of Dryer Before using dryer for the first time, use an all-purpose cleaner, or a detergent and water solution, and a damp cloth to remove shipping dust from inside dryer drum. Step 7: Plug In the Dryer Electric Dryer Connect the dryer to an electrical power source. Refer to Step 4 for information on connecting power cord. Figure 30 Gas Dryer Dryer requires 120 Volt, 60 Hertz electrical supply and comes equipped with a 3-prong grounding plug. Refer to serial plate for specific electrical requirements. NOTE: The wiring diagram is located inside the control hood. When plugging in the dryer: • Do not overload circuits. • Do not use an adapter. • Do not use an extension cord. • Do not operate both a washer and gas dryer on the same circuit. Use separetely fused 15 amp circuits. Figure 27 Figure 28 D604I Figure 29 D317S D317S D606I D606I D604I D275I Connect to 30 Amp circuit. To reduce the risk of fire, electric shock, serious injury or death, all wiring and grounding MUST conform with the latest edition of the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1, and such local regulations as might apply. It is the customer’s responsibility to have the wiring and fuses installed by a qualified electrician to make sure adequate electrical power is available to the dryer. W521 WARNING Installation Each dryer is designed to be operated on a separate branch, polarized, three-wire, effectively grounded, 120 Volt, 60 Hertz, AC (alternating current) circuit protected by a 15 Ampere fuse, equivalent fusetron or circuit breaker. The three-prong grounding plug on the power cord should be plugged directly into a polarized three-slot effectively grounded receptacle rated 120 Volts AC (alternating current) 15 Amps. Refer to Figure 31 to determine correct polarity of the wall receptacle. Grounding Information The dryer unit must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. Each dryer is equipped with a cord having an equipment-grounding conductor and a 3 prong grounding plug. The three-prong grounding plug on the power cord should be plugged directly into a polarized three-slot effectively grounded receptacle rated 110/120 Volts AC (alternating current) 15 Amps. This dryer is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three- prong receptacle. Do not cut or remove the grounding prong from this plug. W036 WARNING WARNING Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the dryer is properly grounded. W038 Do not modify the plug provided with the dryer – if it will not fit the outlet, have a proper outlet installed by a qualified electrician. NOTE: Have a qualified electrician check the polarity of the wall receptacle. If a voltage reading is measured other than that illustrated, the qualified electrician should correct the problem. Do not operate other appliances on the same circuit when this appliance is operating. WARNING To reduce the risk of an electric shock or fire, DO NOT use an extension cord or an adapter to connect the dryer to the electrical power source. W037 M DRY2022N 1 “L1” 2 Ground 3 Neutral 4 Neutral SIde 5 Round Grounding Prong Figure 31 0 V.A.C 120±12 V.A.C Plug cord into separately fused 15 Amp circuit. 3 2 1 4 5 120±12 V.A.C Step 8: Recheck Steps 1-7 Refer to Installer Checklist on the back cover of this manua...
Écrivez votre propre critique du dispositif
|
|