Facilité d'utilisation


Next, use a paper clip to press the RESET button next to the keypad. You will need to reprogram your thermostat and confirm normal operation. If Error Mode returns, please call 888-830-1326 for Technical Assistance from 7 AM to 7 PM Central Time Monday thru Friday and 8 AM to 5 PM Central Time on Saturday. 47 TROUBLESHOOTING Problem Solution 1. Remove clear Mylar sticker 1. Check terminal connection. 2. Check battery connections and batteries. 3. Press RESET button with a small pin and hold in for two seconds. 1. Replace Batteries 2. Adjust LCD contrast in the Option Menu. 1. Check that the time is set properly to “AM” or “PM”. 2. Check that the thermostat is not in “HOLD” or “Home Today” modes. 3. Check for the correct day setting. 4. Check any remote sensor readings or weights. 1. Move HG/HE selector to opposite position 1. Check fan setting. It may be “ON” or in Programmable Fan mode “PGMON”. SCRAMBLED OR DOUBLE DISPLAY (numbers over numbers) NO DISPLAY ENTIRE DISPLAY DIMS PROGRAM DOES NOT CHANGE AT YOUR DESIRED SETTING AUTO / FAN DOES NOT TURN ON FAN RUNS CONTINUOUSLY 1. Check that the system selector key is in the correct position (“HEAT,” “COOL” or “AUTO”). 2. The thermostat may be in the AUTO mode. Look for “AUTO” on the LCD display. If the Heat and Cool program temperatures are close, then the thermostat requires a larger room temperature change before changing from Heat or Cool. 3. There may be as much as a 4 minute delay before the Heat or Cool system turns On - wait and check. (Compressor protection delay.) 4. Check your circuit breakers and switches to ensure there is power to the system. 5. Replace batteries. 6. Make sure your furnace blower door is closed properly. 7. Check the position of the Heat Pump switch. 1. Press the RESET button once with a small pin and hold for two seconds. The thermostat will need to be re-programmed. 1. Replace unit. 1. Replace unit. If you experience any other problems, call 888-830-1326 for Technical Assistance from 7 AM to 7 PM Central Time Monday thru Friday and 8 AM to 5 PM Central Time on Saturday. HEATING OR COOLING DOES NOT GO ON OR OFF Solution (cont.) Problem (cont.) ERRATIC DISPLAY IF UNIT CONTINUES TO OPERATE IN THE OFF POSITION THERMOSTAT PERMANENTLY READS “HI,” “LO,” OR “Error” AFTER PRESSING RESET BUTTON 49 WIRING DIAGRAMS Y/OW/BY1GHeat Relay or ValveRc1RcHeat 24V or Millivolt SupplyRhWallplateTerminalsJumperSystemSelectorHG/HE - SSHP Y/OW/BY1GFan RelayRc1RcHeat/Cool 24V SupplyRhCool ContactorHeat Relayor ValveWallplateTerminalsJumperSystemSelectorHG/HE - SSHP 4-Wire Heat/ Cool System 2-Wire Heat Only System Y/OW/BY1GFan RelayRc1RcHeat 24V SupplyRhHeat Relay or ValveCool ContactorWallplateTerminalsCool 24V SupplySystemSelectorHG/HE - SSHP Y/OW/BY1GFan RelayRc1RcHeat 24V SupplyRhHeat Relay or ValveWallplateTerminalsJumperSystemSelectorHG/HE - SSHP 5-Wire Heat/ Cool System 3-Wire Heat Only System Y/OW/BY1GFan RelayRc1RcHeat Pump 24V SupplyRhCoolModeReversing ValveWallplateTerminalsJumperHeatModeORCompressorContactor Connect to proper Reversing Valve Terminal. See Table ASystemSelectorHG/HE - SSHP Y/OW/BY1GFan RelayRc1RcCool 24V SupplyRhHeat Relay or ValveWallplateTerminalsJumperSystemSelectorHG/HE - SSHP Single-Stage Heat Pump System 3-Wire Cool Only System © 2007 Hunter Fan Co. Hunter Fan Co. 2500 Frisco Avenue Memphis, TN 38114 44008-01 08/09/2007 1 Termostato Programable Modelos 44668 y 44660 44008-02 20080916 2 Tabla de contenido Lea esto antes de instalar el termostato 5 Caracteristicas 8 Lo que usted necesita 8 Retire el termostato antiguo 9 Etiquetado de alambres 10 Monte la placa de pared y el termostato 11 Conecte los alambres y monte el termostato a la placa de pared 12 Menu de opciones 14 Configuracion del canal del sensor remoto 64 Ajuste de hora y dia 16 12 horas. /24 horas. Formato de hora 17 Introduccion a la programacion 18 Programa personal 19 Programacion 21 Programacion de dia de semana / fin de semana 22 Programacion de 7 dias 25 Programacion diaria 27 INTRODUCCION INSTALACION PROGRAMACION (continuacion) Opciones de programa 29 Ventilador programable 29 Tecla de seleccion de sistema 31 Tecla Fan (ventilador) 31 Revision del ajuste de temperatura actual 32 Anulacion manual temporal 33 Anulacion manual permanente 34 Suspension por vacaciones (programable) 35 Cambio automatico por estacion 36 Home Today (Hoy dia en casa) 37 Monitor de energia 39 Monitor de filtro 40 Ajustes SPAN 41 Auto Recuperacion 42 Bloqueo de teclado 43 Luz de fondo (Luz nocturna INDIGLO®) 44 Advertencia de...

Ce manuel est également adapté pour les modèles :
Thermostats - 44660 (3.29 mb)
Thermostats - 44008-01 (3.29 mb)
Thermostats - 44660 (3.29 mb)
Thermostats - 44668 (3.29 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories