Log:
Évaluations - 2, GPA: 4.5 ( )

Instructions Honeywell, Modèle 44660

Fabricant : Honeywell
Taille : 3.29 mb
Nom Fichier : 44008.pdf
Langue d'enseignement: enes
Aller à la télécharger



Facilité d'utilisation


Time Format 18 Programming Introduction 19 Personal Program Schedule 20 Programming 22 Weekday/Weekend Programming 23 7-Day Programming 26 Everyday Programming 28 Program Options 30 INSTALLATION PROGRAMMING (continued) Programmable Fan 30 System Selection Key 32 Fan Key 32 Reviewing the Current Temperature Setting 33 Temporary Manual Override 34 Permanent Manual Override 35 Vacation (Programmable) Hold 36 Auto Season Changeover 37 Home Today 38 Energy Monitor 40 Filter Monitor 41 SPAN Settings 42 Auto Recovery 43 Keyboard Lock 44 Backlighting (INDIGLO® Night-Light) 45 Low Battery Warning 46 Error Mode 46 Problems & Solution 46 Table of Contents (continued) PROGRAMMING (continued) OPERATIONS Technical Support 48 Technical Support 49 OPERATIONS (continued) TROUBLESHOOTING WIRING DIAGRAMS Read This Before Installing Thermostat IMPORTANT 1Read the entire installation section of this Owner’s Manual thoroughly before you begin to install or operate your Hunter Thermostat. INSTALLATION 2All installation is normally performed at your thermostat. ARMCHAIR PROGRAMMING 3You can program your thermostat before installation by inserting the batteries and following the instructions starting on page 12. This can be done while you relax in your favorite chair and is a very good way to familiarize yourself with all the functions of your Hunter Thermostat. SYSTEM COMPATIBILITY 4Your Thermostat is designed to operate with most gas, oil, electric, or 2-wire hot water heating and air conditioning systems. It will also operate single-stage heat pumps that do not have auxiliary or emergency heat. These have 24 volt or millivolt control systems and represent most central heating, air conditioning, or space heating units in the United States. This thermostat will not control 120/240 Volt systems or millivolt systems. COMPRESSOR PROTECTION 5The thermostat provides a 3.5 minute delay after shutting off the heating or cooling system before it can be restarted. This feature will prevent damage to your compressor caused by rapid cycling. TEMPERATURE RANGE 6Your thermostat can be programmed between 45°F and 95°F (7°C and 35°C). However, it will display room temperatures from 15°F to 99°F (-9°C and 37°C). “HI” will be displayed if the temperature is higher than 99°F (37°C), and “LO” will be displayed if the temperature is lower than 15°F (-9°C). AUTO RECOVERY 7Your thermostat is set from the factory to gradually recover the room temperature from an energy saving program to your comfort program. Therefore, the thermostat may turn your system on several minutes prior to your programmed time. This operation is normal, but can be turned off. Refer to the Options Menu information on pages 15. BATTERY WARNING 8Two fresh AA alkaline batteries should provide well over one year of service. However, when the batteries become drained, the Low Battery Indicator will flash on the display. when this message occurs, install new alkaline batteries. You have appoximately one minute to change the batteries and keep the thermostat’s clock and program settings. Once the batteries have become too low to ensure proper operation, your system will be turned off. The display will be cleared except for the flashing Low Battery Indicator on the LCD display, and all programming will be lost. CAUTION: When only the battery Icon flashes on the display, the thermostat is shut down and your system will no longer operate. In this condition, there is no temperature control of your dwelling. NOTE: If you plan to be away from the premises over 30 days, we recommend that you replace the old batteries with new alkaline batteries prior to leaving. REMOTE SENSORS (does not apply to thermostat model 44660) 1Your thermostat can support 3 remote sensors that will measure the temperature from three different locations - two indoor and one outdoor. To configure your thermostat to work with the remote sensors, follow the instructions for Sensor Channel selection on page 13 of this manual. To configure the remote sensors, consult the Remote Sensor Instruction Manual. NOTE (does not apply to thermostat model 44660): This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed t...

Ce manuel est également adapté pour les modèles :
Thermostats - 44008-01 (3.29 mb)
Thermostats - 44660 (3.29 mb)
Thermostats - 44668 (3.29 mb)
Thermostats - 44008-01 (3.29 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories