Follow all lock out/tag out procedures established by the user. Verify all power is off to the unit before performing any work. Failure to comply could result in serious injury, death or damage to the equipment. 1. Open kit and remove new parts. 2. Insert the new metal thermostat well into the small, non flared end of the tube and seal it with V to V2 inch of food grade silicone. Let set for 15-30 minutes. 3. Turn the machine off. 4. Remove panels, as needed. 5. Gently pull gray sensing bu