Log:
Évaluations - 1, GPA: 5 ( )

Instructions AEG, Modèle FM 6300G-AN

Fabricant : AEG
Taille : 443.19 kb
Nom Fichier : 888281EN.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Write the serial number on the front of this instruction book so it is easily accessible in the event of service. Removal of Packaging All packaging can be recycled. Contact your local authority if you do not know where to dispose of the packaging. 16 Technical Data This gas appliance is CE-approved and CE-marked in accordance with the Gas Appliance Directive (90/396/EEC, Low Voltage Directive (73/23/EEC) and the EMC Directive (89/336/EEC as amended). Approval authority: 0048 (Danmarks Gasmateriel Provning). Model FM 6300G-an Product dimensions: Width: 580 mm Depth: 520 mm Height: 66 mm Installation dimensions: Width: 560 mm Depth: 490 mm Height: 55 mm Output (natural gas) Rear left 3 kW Front left 1.9 kW Rear right 1.9 kW Front right 1 kW Total output 7.8 kW Gas consumption Natural gas 0.74 m3/h LPG 598 g/h Consumption given as the max. nominal gas consumption Category and pressure: GB: II2H3+ -20 - 28/37 mbar Nozzle/connection pressure Natural gas 20 mbar LPG 30 mbar FM 6300G-an is adjusted for natural gas G20-20 mbar. An LPG conversion kit is included. Voltage 230 V Ignition transformer 50 Hz, 0.6 VA CE identification no.: 048BN-0042 17 Important safety requirements This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). Detailed recommendations are contained in the following British Standards Codes Of Practice: B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891 Current Editions. The hob should not be installed in a bed sitting room with a volume of less than 20 m.. If it is installed in a room of volume less than 5 m. an air vent of effective area of 110 cm. is required. If it is installed in a room of volume between 5 m. and 10 m. an air vent of effective area of 50 cm. is required, while if the volume exceeds 11 m. no air vent is required. However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m. and 11 m.. If there are other fuel burning appliances in the same room, B.S. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements. This hob must be installed by qualified personnel to the relevant British Standards. Any gas installation must be carried out by a CORGI registered installer. The maufacturer will not accept liability, should the above instructions or any of the other safety instructions incorporated in this book be ignored 18 Installation Gas installation Installation may only be carried out by a Corgi registered installer. Work carried out by unqualified persons may lead to personal injury and/or damage to property, and may damage the product. This gas appliance is CE-approved and CE-marked in accordance with the Gas Appliance Directive (90/396/EEC, Low Voltage Directive (73/23/EEC) and the EMC Directive (89/336/EEC as amended). Gas installation must be carried out in accordance with the Gas Regulations (GR). No alterations must be made to the technical design of this appliance. Leak test When leak testing, the appliance may be tested to a maximum of 150 mbar. 19 PE Electronic Control Cable type 0.75 mm2 HO5 VV-F Installation must comply with any special requirements laid down by the local energy provider. The product must be connected via an external switch with a contact gap of at least 3 mm. (May be the main switch). L L1 N L2 N 20 Mounting The hob can be installed in any type of kitchen worktop with a thickness of 28-40 mm. However, if an oven is to be installed beneath it, the work- top must be at least 40 mm thick. Cutting Out When mounting this hob: Read the instructions on this and the following page. When mounting this hob in conjunction with other units in this range: Read the instructions in the section “Mounting more than one hob”. For mounting this hob you will need a Phillips screw driver and the four fixings supplied (See fig.). Distance to wall: Min. 150 mm from flammable material. Min. 50 mm from non-flammable material. Clamping fittings 21 However, to ensure accessibility to the gas connection there should generally be at least 50 mm between the rear of the hole for the gas hob and the wall behind it. 1. Cut a hole in the worktop of the given dimensions, see “Technical data”, “installation dimensions”. 2. Place the hob upside down on a soft underlay. Make sure not to scratch the top surface. 3. Mount the fixings in the holes in the sides of the base box. (See fig.). 4. Insert the hob in the hole and tighten the fixings to the worktop with a screwdriver. Mounted clamping fittings 22 23 Mounting more than one hob Cutting out The measurement of the selected combination is calculated in the following way: Depth: 490 mm Width: 1. Calculate the sum of all units’ width. 2. Subtract 20 mm from the total width. Example: A hob of 720 mm + a downdraft of 180 mm + a gas hob of 360 mm. 1. 720+180+360= 1260 mm 2. Width of the hole: 1260-20=1240 mm Distance to Wall: Min. 150 mm to f...

Ce manuel est également adapté pour les modèles :
Hobs - FM 6300G-AN (443.19 kb)
Hobs - FM 6300G-AN (443.19 kb)
Hobs - FM 6300G-AN (443.19 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories