Log:
Évaluations - 2, GPA: 4 ( )

Instructions AEG, Modèle CGA 75 WOK

Fabricant : AEG
Taille : 110.53 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


The voltage of the electric system must correspond to the value indicated in the label under the appliance. Make sure that the electric system is provided with an effective ground connection in compliance with the regulations and provisions of the law. Grounding is compulsory. 6 D -Installation & Warnings D -Installation & Warnings GAS TRANSFORMATIONS AND ADJUSTMENTS Replacing the nozzles If the equipment is adjusted for a type of gas that is different from the original, it is necessary to replace the burner nozzles as well. The nozzles used to replace the original must be in accordance with the table of the technical characteristics enclosed. To remove the racks and burners by means of a straight spanner ‘L’, unscrew the nozzle ‘U’ (Fig.8) and substitute it with the corresponding one and tighten the nozzle. Adjusting the burners The flame should always stay alight when the burner is switched on, even if there is an abrupt shift from the maximum to minimum flame position. If the flame does not stay alight, adjust it as follows: – Start the burner – Turn the tap up to the minimum position (small flame) – Remove the knob from the tap rod – Using a flat-tip screwdriver ‘C’ into the hole ‘F’ of the tap (fig.9) turn the by-pass screw up. MAINTENANCE Lubricating the taps In the case of tap hardening, it is necessary to disassemble the tap and grease it. – Unscrew the two screws that lock the head flange of the tap. – Lift the gas adjusting cone and carefully clean it with gasoline or diluent. – Spread a little high-temperature grease on it, making sure that the gas holes are not obstructed. – Reassemble all of the parts with care. Replacing the power supply cable If the power supply cable needs to be replaced, it is necessary to use a cable with a section of 3x0.75mm2, type H05VV-F or H05RR-F, complying with the regulations in force. NOTE: The connection to the terminal board must be effected as shown in fig. 10 - 10A: Brown cable L (phase) Blue cable N (neutral) Green-yellow cable (ground) 7 81 2 3 4 5 6A 6 87 9 10 10/A 1 2 3 4 5 6A 6 87 9 10 10/A E -Technical Diagrams E -Technical Diagrams CGA 60 WOK CGA 75 WOK CGA 90 WOK F -Technical Characteristics Table BURNERS GAS NORMAL PRESSURE mbar INJECTOR DIAMETER 1/100 mm TAPE BY PASS DIAMETER 1/100 mm NOMINAL HEAT INPUT MAX. MJ/h (Btu/h)N° DESCRIPTION 1 RAPID PROPANE NATURAL 28 10 92 155 42 REG. 11.6 (11000) 2 SEMI-RAPID PROPANE NATURAL 28 10 72 120 31 REG. 6.3 (6000) 3 AUXILIARY PROPANE NATURAL 28 10 55 90 27 REG. 3.2 (3000) 4 WOK PROPANE NATURAL 28 10 107 175 60 REG. 17.9 (17000) The manufacturing firm refuses all responsibility for any possible imprecision in this booklet, due to misprints or clerical errors. It reserves the right to make all the changes that it will consider necessary in its own products, without affecting the essential characteristics of functionality and safety. 9 E -Technical Diagrams E -Technical Diagrams CGA 60 WOK CGA 75 WOK CGA 90 WOK POWER (MJ/h) POWER (Btu/h) 1 Rapid burner 11...

Ce manuel est également adapté pour les modèles :
Hobs - CGA 60 WOK (110.53 kb)
Hobs - CGA 60 WOK (110.53 kb)
Hobs - CGA 60 WOK (110.53 kb)
Hobs - CGA 90 WOK (110.53 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories