Log:
Évaluations - 3, GPA: 4.3 ( )

Instructions GE, Modèle GE Monogram ZVC42

Fabricant : GE
Taille : 3.53 mb
Nom Fichier :
Langue d'enseignement: enesfr
Aller à la télécharger



Facilité d'utilisation


Minimum required *36. Maximum recommended installation height Cooktop *Always refer to the cooktop or range installation instructions for product-specific clearances. • The insert sleeve in the canopy must be centered left to right over the cooktop. Left side view *30. Minimum required *36. Maximum recommended installation height Illustrations not to scale 14 Installation Preparation WARNING: Disconnect electrical power from unit before beginning remote control installation. Failure to do so could result in personal injury or damage to the electrical controls. REMOTE LOCATION FOR CONTROL NOTE: The hood is only certified for use with the supplied 30-ft. length of wire. The control can be removed from the hood and installed in a backsplash or countertop. • A cover plate is provided to cover the opening in the hood when the control is removed. • A 30-ft. length of 4-wire cord is supplied to accommodate most installations. Because only 30-ft. of cord is provided, careful consideration must be given to the location of the remotely mounted control. • The 30-ft. cord is supplied with a connector/ converter on one end. DO NOT REMOVE the connector/converter from the 30-ft. cord. Failure to use the connector/converter with the shorter cord will prevent proper operation of the control. NOTE: Not for telecommunication (telephone) network. • The cord must be routed through the holes in the insert sleeve, and the rubber grommets put into place around the cord. NOTE: On the ZVC30 and ZVC36 models, the cord needs to be routed through the holes in the insert sleeve before the damper plate is installed. • Route the cord through the conduit to reach the installation location of the control. 1-11/16. 3-11/16. Control cutout REMOTE MOUNTING OF THE CONTROL – WIRED Main PCB Long cord Display board Connector/ converter Short cord Remotely Mounted Control—Wall or Countertop Installation 15 Installation Preparation COUNTERTOP 1. Cut out opening in the countertop. Cutout dimensions are 1-11/16. x 3-11/16.. 2. Loosen the 4 thumbscrews and remove the control from the insert sleeve. Replace the control with the blanking plate provided. 3. Attach the mounting plate to the back of the control with the 2 mounting plate screws. 4. Pull the 4-wire cord through the opening in the countertop, and through the back of the mounting bracket. NOTE: Use provided cables and connector/ converter ONLY. 5. Connect the 4-wire cord to the jack of the connector on the remotely mounted control. 6. Press the control firmly into the mounting bracket so that the clips engage. 7. Apply silicone around the cutout opening. 8. Insert the control into the cutout opening. WALL MOUNT 1. Cut out opening into the wall surface. Cutout dimensions are 1-11/16. x 3-11/16.. 2. Loosen the 4 thumbscrews and remove the control from the insert sleeve. Replace the control with the blanking plate provided. 3. Attach the mounting plate to the back of the control with the 2 mounting plate screws. 4. Pull the 4-wire cord through the opening in the wall, the wall bracket and the back of the mounting bracket. NOTE: Use provided cables and connector/ converter ONLY. 5. Connect the mounting bracket to the wall bracket using the two wall bracket screws. Only start the first 1–2 threads of the screws into the wall, as you want to leave a gap between the two brackets to account for the wall thickness. 6. Raise the tabs on the mounting bracket so the bracket will fit through the wall opening. 7. Angle the mounting and wall brackets and slide them through the wall cutout. NOTE: Attach a string to the brackets, so you can retrieve them from behind the wall if dropped. 8. Flatten tabs on mounting bracket so they are flush with the wall surface, and tighten the wall bracket screws to pull the wall bracket flanges flush with the backside surface of the wall. 9. Connect the 4-wire cord to the jack of the connector on the remotely mounted control. 10. Press the control firmly into the mounting bracket so that the clips engage. 4-wire cord Mounting bracket Screws Connector Apply silicone around cutout opening Mounting plate Control 4-wire cordScrews Jack Mounting plate ControlWall bracket Mounting bracket Tabs REMOTE MOUNTING OF THE CONTROL – WIRED (Continued) 16 Installation Instructions STEP 1 INSTALL HOOD LINER 1. Frame the cutout opening to fit the liner. NOTE: The opening support must be 3/4. thick wood to accept the liner installation screws. 2. Slide the liner up and into the opening until flush with bottom edges. 3. Secure the liner to the cabinet with 6 screws provided. 17 18 Installation Instructions STEP 2 CONNECT ELECTRICAL Verify that power is turned off at the source. WARNING: If house wiring is not 2-wire with a ground wire, an electrician will need to convert existing wiring to meet these specs. When house wiring is aluminum, be sure to use U.L.-approved anti-oxidant compound and aluminum-to-copper connectors. 1. Place insert sleeve on padded, yet stable, surface below cutout (can u...

Ce manuel est également adapté pour les modèles :
Ventilateurs - GE Monogram ZVC30 (3.53 mb)
Ventilateurs - GE Monogram ZVC36 (3.53 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories