|
Facilité d'utilisation
A blanking plate covers the opening when the controls are removed. The overall size of the control is 4-1/4. wide and 2-1/4. deep. The stainless steel liner is shipped with each hood insert. This non-combustible liner protects the underside of the canopy. Custom Liner If you are not using the supplied liner, you may construct a custom non-combustible liner. Use the supplied liner as a template. The opening must be 38-3/4.W x 13-3/16.D. 3/4. thick material must surround the opening to allow the sleeve locking clips to engage. The insert sleeve inside the cabinet should be positioned 1/2. from the rear wall so that the center of the 8. duct is 5-1/2. from the *Opening ZVC48 The custom canopy must be sized to fit the insert sleeve. Construct the canopy with an opening that is: 38-3/4.W x 13-3/16.D The opening must be constructed of 3/4. thick material to allow the sleeve locking clips to engage. The Supplied Liner Dimensions and Specifications (in inches) Outside Dimensions The Insert Sleeve 38-1/2. 13. 14. 29-1/2. 1/2. 1/2. 1/2. 13. 1-11/16. 3-11/16. Control cutout 14. 39-1/2. Front side Front side rear wall. We recommend that the cutout in granite or other hard surfaces be made before the countertop is installed. 8 Advance Planning ADVANCE PLANNING Ductwork Planning •This hood is equipped for 8. round ductwork. •Determine the exact location of the vent hood. •Plan the route for venting exhaust to the outdoors. This hood is not designed for a recirculating venting operation. •Use the shortest and straightest duct route possible. For satisfactory performance, duct run should not exceed 100 ft. equivalent length for any duct configurations. •Refer to “Duct Fittings” chart to compute the maximum permissible length for duct runs to the outdoors. •Use rigid metal ductwork only. •Install a wall or roof cap with damper at the exterior opening. Order the cap and any transitions needed in advance. Wall and Ceiling Framing for Adequate Support This vent hood is heavy and the cabinet structure needs to support the weight of the loaded insert sleeve. Adequate structural support must be provided in all types of installations. •Installation will be easier if the vent hood is installed before the cooktop is installed. Custom Cabinet Frame Planning •The custom-built canopy should be sized to accommodate the hood insert sleeve. See pages 5–9 for details. Remote Mounting of the Control (Wired) •The control can be remotely mounted on the wall or the countertop. •It is recommended that you use a professional installer for the countertop cutout. •It is recommended that the cutout in a granite countertop or other hard surface be made before the countertop is installed. •The cutout needs to be made at least 6 inches from the edges of the countertop. •If mounting in the countertop above a drawer, consideration must be given to the depth of the control mounting assembly. •A 30 ft. wire cord is provided. Careful consideration must be given to the location of the remotely mounted control. •It is recommended that the 4-wire cord be routed through 1. conduit between the insert sleeve and the remote mounting location. POWER SUPPLY IMPORTANT - (Please read carefully) WARNING: The grounding conductor must be connected to a grounded metal, permanent wiring system, or an equipment-grounding terminal or lead on the hood. Grounding Instructions • House wiring must extend to 45. minimum from bottom of cabinet in order to make connection to hood wiring. • Connect the hood wiring to the house wiring in accordance with local codes. • Route house wiring as close to the installation location as possible, in the ceiling or back wall. equirements, call a licensed electrician before oceeding. • If the electrical supply does not meet the above • Wiring must be 2 wire with ground. This vent hood must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit, and protected by a 15 or 20 amp circuit breaker or time delay fuse. Electrical Supply Do not use an extension cord or adapter plug with this appliance. Follow National electrical codes or ailing local codes and ordinances. FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE prbeginning installation. Remove house fuse or open circuit breaker beforePROPERLY GROUNDED. WARNING: The improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded. 9 Advance Planning DUCT FITTINGS This Hood Must Use an 8. Round Duct. It Can Transition to a 3-1/4. x 12. Duct. Use this chart to compute maximum permissible lengths for duct runs to outdoors. NOTE: Do not exceed maximum permissible equivalent lengths! Maximum duct length: 100 foot for range hoods. Flexible ducting: If flexible metal ducting is used, all the equivalent feet values in the table should be doubled. The flexible metal duct should be straight and smooth and extended as m...
Ce manuel est également adapté pour les modèles :Ventilateurs - GE Monogram ZVC36 (3.53 mb)
Ventilateurs - GE Monogram ZVC42 (3.53 mb)