Log:
Évaluations - 2, GPA: 4.5 ( )

Instructions Zephyr, Modèle AK7500ASX

Fabricant : Zephyr
Taille : 393.09 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Place cap over threaded end of remote blower wiring and secure by turning clockwise. 1. Place 10” round adapter on top of hood and 2. Install threaded end of remote blower wiring secure with (4) M4x8 screws. Connect 10” through external blower wiring knock out round duct work to 10” round adapter. located inside the hood. CBE-1000 / PBN-1000A: WIRING DIAGRAM 4. Connect 6 pin male connector from remote blower wiring to 6 pin female connector on control board wire inside hood. Secure green ground wire from external blower wiring to ground screw on hood. Remote Blower Wiring Box (hood) White (common) Junction Box (Remote Blower) Black (high) Blue (med) Red (low) Green (ground) NOTE: For instructions on mounting the remote blower, please refer to the CBE-1000 or PBN-1000A manual included in the remote blower packaging and on our website: 14 15 F The standard baffle filters are required to be cleaned frequently and as recommended in order to maintain blower efficiency. If improperly maintained, residue from cooking will sift through filters and cause damage to hood blowers and other sensitive components; and possibly clog duct work and create a fire hazard. Blower On/Off Adjust 3 Speed Levels 5 Min Delay Off Lights On/Dim/Off Display (Speed level, Delay Off Indicator) 1 2 3 4 5 Blower On/Off By pressing , the blower is switched On and Off. When switched on, the blower turns on at the same speed it was switched off at. When switched off the entire hood powers off, including the lights. Speed Selection The 3 speed levels are selected by pressing to decrease and to increase speed level. The display indicates speed level selected. Pressing when the hood is off will also turn it on. Delay Off This is used for programmed shut down of blower and lights 5 minutes after the function is activated. Press once, a dot displays in the lower right hand side of display indicating the function is on. The hood will change to speed 1 and shut down after 5 minutes. Lights On/Dim/Off Switch lights On by pressing once, again to dim and again to switch Off. Baffle Filter Clean Reminder After every 30 hours of use the display will start flashing an reminding you to clean the baffle filters from residue and possible clogs. 1 2 3 4 Display Displays blower speed level, delay off status and filter clean/replace notification. 5 Heat Lamps On/Off Located on the right and left side light panel are manual power on/off toggle switches. These switches are used to turn the heat lamps on/off. Toggle between I (on) or 0 (off). Clean Air Feature Clean Air is a feature that turns the blower on every 4 hours for 10 minutes to remove stagnant air in the kitchen. This feature is disabled by default and must be enabled by the user. Features & Controls – Touch Controls 16 Baffle Filter Clean Reminder Whether your hood is installed as an exhaust or purifying unit, a set if baffle filters are fitted by the factory, These baffle filters are intended to filter out residue from cooking. They need not be replaced on a regular basis but are required to be kept clean. The filter clean reminder function in the microprocessor will automatically indicate by a flashing when the baffle filters need to be cleaned after every 30 hours of use. Filters can be cleaned by hand with non-abrasive soap or in a dishwasher. Heavily soiled filters should also be soaked in grease cutting detergent prior to cleaning. Baffle Filter Clean Indicator When flashes on display, the baffle filters installed are required to be cleaned. This will occur after every 30 hours of use. Re-setting Function Reset the filter clean reminder timer when filters are cleaned and re-installed (with hood off). Press and hold for approximately 5 seconds, the display will appear; hold for approximately 5 seconds until on display disappears . The filter clean reminder function is now reset and a new 30 hours elapse cycle is initiated. F Clean Filters display < F > flashes F hold 5 sec. display from < F > to < > To Reset F F F To enable Clean Air Feature With hood off, press and hold for approximately 5 seconds until the display shows then . To disable Clean Air Feature With hood off, press and hold for approximately 5 seconds until the display shows then . A - Clean Air Feature Clean Air is a feature that turns the fan on every 4 hours for 10 minutes to remove stagnant air in the kitchen. This feature is disabled by default and must be enabled by the user. When the clean air function is enabled, the blower will turn on speed 1, the display will flash between and until the 10 minute cycle has elapsed and the blower shuts down. 1 - hold 5 sec. display from < - > to < A > To Enable A A A - - hold 5 sec. display from < A > to < - > To Disable A Features & Controls – Touch Controls SURFACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouring pads which will scratch and damage surface...

Ce manuel est également adapté pour les modèles :
Ventilateurs - AK7536ASX (393.09 kb)
Ventilateurs - AK7548ASX (393.09 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories