Log:
Évaluations - 4, GPA: 3.8 ( )

Instructions Best, Modèle EXTRACTORHOOD 125 D

Fabricant : Best
Taille : 200.6 kb
Nom Fichier : 498410EN.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Introductio. . Extraction mod. . Recirculation mod. . Electrical connection for U. . Technical detail. . Installatio. . Safety warnings for kitchen unit installe. . Wall mountin. . Hood operatio. 1. Safety warnings for use. 1. Maintenance and car. 1. Opening the gri. 1. Grease filte. 1. Carbon filte. 1. Changing the light bul. 1. Cleanin. 1. Accessorie. 1. Something not workin. 1. Service & Spare Part. 1. Printed on recycled paper. AEG . putting words into action. Introductio. Extraction mod. l The hood is supplied as an extractor unit and can also be used as . filtered function (recirculation) by fitting activated carbon filter. (available as an accessory). l The unit features two outlet holes, one of which A is located on th. top of the unit while the other B is located on the rear. l To connect up the hose, you should first fit the bayonet-mountin. flange C (O 100-120 mm) on the outlet required (if using the to. outlet, fix the flange in place using the screw supplied as shown i. Fig. 1). Close off the unused hole using the bayonet fitting caps D. 1 C A B D D A B C l Important! To use the back hole B, remove switch F from thetop hole. . Fig 2. l Move the lever L to position A . Fig. 3. l When connecting the hood using a telescopic wall pipe, you should use a non-inflammable outlet hose ABS 120(120 mm O) E-Nr. 942 118 611 from our range of special accessories. Recirculation mode l The air is filtered and recirculated through the front grid. l Move the lever L to position F . Fig. 3. You will need an original KFF activated carbon filter. (Seeaccessories). Summer/Winter Hood Conversion l To avoid excessive heat loss during the winter months, werecommend that the hood be converted from extraction modeto recirculation. l In order to convert the hood, a charcoal filter (available as anaccessory) is required. Follow the instructions for operating thehood to recycle air. l When the temperature outdoors becomes more mild (spring), the filter can be removed and the hood converted once again toextraction. Please consult the assembly instructions for operatingthe hood in extraction mode. 3 LL l Move the lever L to position A . Fig. 3. l When connecting the hood using a telescopic wall pipe, you should use a non-inflammable outlet hose ABS 120(120 mm O) E-Nr. 942 118 611 from our range of special accessories. Recirculation mode l The air is filtered and recirculated through the front grid. l Move the lever L to position F . Fig. 3. You will need an original KFF activated carbon filter. (Seeaccessories). Summer/Winter Hood Conversion l To avoid excessive heat loss during the winter months, werecommend that the hood be converted from extraction modeto recirculation. l In order to convert the hood, a charcoal filter (available as anaccessory) is required. Follow the instructions for operating thehood to recycle air. l When the temperature outdoors becomes more mild (spring), the filter can be removed and the hood converted once again toextraction. Please cons...

Ce manuel est également adapté pour les modèles :
Ventilateurs - EXTRACTORHOOD 125 D (200.6 kb)
Ventilateurs - EXTRACTORHOOD 125 D (200.6 kb)
Ventilateurs - EXTRACTORHOOD 125 D (200.6 kb)
Ventilateurs - EXTRACTORHOOD 125 D (200.6 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories