Instructions Electrolux, Modèle EXTRACTORHOOD 125 D

Fabricant : Electrolux
Taille : 200.6 kb
Nom Fichier : 498410EN.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


The terminology .DOUBLE POLE. means that both the live and th. neutral supplies are switched and disconnected at the same time. The terminations labelled SUPPLY are for the connection for th. internal house wiring and the terminations labelled LOAD are for th. appliance. IMPORTAN. The wires of the mains lead supplied with this appliance ar. coloured in accordance with the following code. Blue-Neutra. Brown-Liv. As the colours of the flexible cord of this appliance may no. correspond with the coloured markings identifying the termi. nals in the plug, proceed as follows: The wire which is coloure. brown must be connected to the terminal which is marke. with the letter L or coloured red. The wire which is coloured blue must be connected to th. terminal which is marked with the letter N or coloured black. N LOAD L SUPPLY L LOAD N SUPPLY DP 13A, 250V BLUE (NEUTRAL) BROWN (LIVE) FUSE ON Technical detail. Dimension. Height x Width x Depth (in cm. 69-113 x 59.9 x 5. Weigh. Net. 11,5 k. Gross. 12,6 k. Maximum absorbed power. 205 . Motor absorptio. 1 x 125 . Lighting. 2 x 40 . Length of the cable. 110 c. Fan powers (speed), speed in compliance with DIN 4497. Extraction mod. . 115 m3/. . 152 m3/. . 210 m3/. Recirculation mod. . 110 m3/. . 129 m3/. . 145 m3/. Flange:100-120 mm . Installatio. Safety warnings for kitchen unit installe. l When used as an extractor unit, the hood must be fitted with . 100 or120mm diameter hose. l If the fumes must be forced out through the wall, you mus. obtain a MKZ sizable wall exhaust pipe (with external exhaust an. air intake), E-Nr.- 610 899 004 (O 120 mm) which is one of ou. optional parts. l When installing the hood, make sure you respect the fol. lowing minimum distance from the top edge of the cookin. hob/ring surfaces. Electrica. 650 m. Gas ho. 700 m. Electric cooke. 685 m. Gas cooke. 787 m. l The hood cannot be connected to flues of other appliances tha. run on energy sources other than electricity. l The air outlet must not be connected to chimney flues or com. bustion gas ducts. The air outlet must under no circumstances b. connected to ventilation ducts for rooms in which fuel-burnin. appliances are installed. l It is advisable to apply for authorization from the relevan. controlling authority when connecting the outlet to an unuse. chimney flue or combustion gas duct. The air outlet installation must comply with the regulations lai. down by the relevant authorities. l When the unit is used in its extractor version, a sufficiently larg. ventilation hole must be provided, with dimensions that ar. approximately the same as the outlet hole. l National and regional building regulations impose a number o. restrictions on using hoods and fuel-burning appliances connecte. to a chimney, such as coal or oil room-heaters and gas fires, i. the same room. l Regulations on fuel-burning systems specify a maximu. depression of 0.04 bar in such rooms. l Hoods can only be used safely with appliances connected to . chimney if the ro...

Ce manuel est également adapté pour les modèles :
Ventilateurs - EXTRACTORHOOD 125 D (200.6 kb)
Ventilateurs - EXTRACTORHOOD 125 D (200.6 kb)
Ventilateurs - EXTRACTORHOOD 125 D (200.6 kb)
Ventilateurs - EXTRACTORHOOD 125 D (200.6 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories