Log:
Évaluations - 4, GPA: 3.5 ( )

Instructions IDEAL INDUSTRIES, Modèle MINI HE C28

Fabricant : IDEAL INDUSTRIES
Taille : 187.56 kb
Nom Fichier : bcf160f7-0056-4068-88d8-4936d400c6c9.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


appliance No. 47- ---348- ---38 mini HE C28 G.C. appliance No. 47- ---348- ---39 Destination countries: GB, IE INTRODUCTION mini HE are wall mounted, room sealed, condensing, low water content combination gas boilers featuring full sequence automatic spark ignition and fan assisted combustion. SAFETY Current Gas Safety (Installation & Use) Regulationsorrules in force In your own interest, and thatof safety, it is the law that this boiler must be installed by a CORGI registered installer or in IE a competent person, in accordance with the above regulations. It is essential that the instructions in this booklet are strictly followed, for safe and economical operation of the boiler. ELECTRICITY SUPPLY Theappliancemustbeefficiently earthed. Supply 230 V 50 Hz. The fusing should be 3 A. Connection must be made in a way that allows complete isolation of the electrical supply, such as a double pole switch, having a 3 mm (1/8.) contact separation in both poles, or a plug and socket serving only the boiler and system controls. The means of isolation must be accessible to the user after installation. IMPORTANT NOTES L This appliance must not be operated without the casing correctly fitted and forming an adequate seal. L If the boiler is installed in a compartment then the compartment MUST NOT be used for storage purposes. L Under no circumstances should any of the sealed components on this appliance be used incorrectly or tampered with. L If it is known or suspected that a fault exist on the boiler then it MUST NOT BE USED until the fault has been corrected by a CORGI registered installer or in IE a competent person. MINIMUM CLEARANCES Clearances of 200 mm (7 7/8.) above and below, 25 mm (1.) at left, 50 mm (2.) at right and 450 mm (17 3/4.) at the front of theboilercasemustbeallowed for servicing. After installation the following clearances are allowable during use, providing the encasing parts are removeable for servicing: The bottom clearance can be reduced to 20mm (3/4.). The front clearance can be reduced to 50mm (2.). BOILER CONTROLS A B C D E F G A B C D Appliance operation lights Domestic hot water temperature control Main switch and radiator temperature control Boiler reset button E F G Lock---out signal lamp Programmer (optional) System pressure and temperature gauge TO LIGHT THE BOILER 1 Check that the valves located in the lower part of the boiler are open. 2 Switch the electricity supply on. The appliance operation light A will flash every 4 seconds (stand---by condition). 3 If the boiler is to be used for CH and DHW position the main switch as in the following illustration. The appliance operation light A will flash every 2 seconds (operating boiler). A DIAGNOSTIC LIGHTS The following table gives a summary of the relationship between each of the possible light combinations and their meaning during normal operaion of the boiler All CORGI registered installers carry a CORGI ID card, and have a registration number. Both should be recorded in the Benchmark Commissioning Checklist. You can check your installer by calling CORGI direct on 01256 372300. Caradon Ideal Limited is a member of the Benchmark initiative and fully supports the aims of the programme. Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety and efficiency. THE BENCHMARK SERVICE INTERVAL RECORD MUST BE COMPLETED AFTER EACH SERVICE Normally operating boiler CH operation DHW operation Frost protect operation Lamp Flashing lamp, alone Flashing lamp, OFF or simultaneously alternate with with an other lamp. another lamp. If the lights sequence observed on the boiler is not included above then a fault is indicated. reference should be made to the Installation Instructions or consult a CORGI registered installer. CONTROL OF CH TEMPERATURE The output temperature of CH water is adjustable from a minimum of about 38°C to a maximum of about 85°Cby turning the knob C. Approx CH flow temperatures for the boiler thermostat settings: Minimum(38uC) Maximum (85 uC) C CONTROL OF DHW TEMPERATURE Thetemperature of theDHW leaving the boiler can bevaried from a minimum of about 35°C to a maximum of about 55°C (within the power limits of the appliance) by turning the temperature control knob B. Minimum (35 uC) Maximum (55 uC) B Adjustment of the DHW temperature is completely separate from that of the CH circuit. The adjustment system integrated within the boiler automatically controls the flow of gas to the burner in order to keep the temperature of DHW delivered constant, between the limits of maximum and minimum output. Where the demand is at a low level or with the temperature set to the minimum, it is normal to see a cycle of lighting and extinguishing of the burner when running. Adjustment It is advisable to adjust the DHW temperature to a level commensurate with the demand, minimising the need to mix ...

Ce manuel est également adapté pour les modèles :
Chauffe-eau - MINI HE C24 (187.56 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories