Log:
Évaluations - 1, GPA: 5 ( )

Instructions IDEAL INDUSTRIES, Modèle MINI HE C24

Fabricant : IDEAL INDUSTRIES
Taille : 187.56 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


The appliance operation light A will flash every 4 seconds. For long periods When you do not expect to use the boiler for a long period: 1 Switch the electricity supply off. 2 Shut off the gas supply cock and the valves for the water circuits fitted under the boiler. 3 If necessary, empty the water circuits. FROST PROTECTION This appliance is provided with a built in anti---freeze system that operates the boiler when the temperature is below 5 uC Therefore, when the boiler is not lit and used in cold weather, with consequent risk of freezing do not isolate the boiler from the electricity supply or close the gas inlet cock. ESCAPE OF GAS Should a gas leak or fault be suspected contact your local gas supplier without delay. Do not search for gas leaks with a naked flame. CLEANING For normal cleaning simply dust with a dry cloth. To remove stubborn marks and stains use a damp cloth and mild detergent. Do not use abrasive cleaning materials. MAINTENANCE The appliance should be serviced at least once a year by a CORGI registered installer. FAULTS No heating or hot water Check that gas and electricity are available at the boiler and that all switches are on. Check that the system water pressure gauge G reads at least 0,5 bar. Check the lock---out signal lamp E. If it is illuminated press the boiler reset button D to restart the ignition sequence. Hotwater butno heating Check that the programmer and room thermostat (if fitted) are both calling for heat. Heating but no hot water Check that cold water flows out of the taps at a minimum rate of 3.5 litres per minute (or 1 pint in 10 seconds or less). If not, look for stop valves not fully open. If thesesimplechecksfailto solve theproblem, orthe problem recurs, consult your service engineer. Points forBoilerUser Note. In line with our current warranty policy we would ask that you check through the following guide to identify any problems external to the boiler prior to requesting a service engineers visit. Should the problem be found to be other than with the appliance we reserve the right to levy a charge for the visit, or for any pre---arranged visit where access is not gained by the engineer. Troubleshooting - ---Typical Non Product Faults Problem Solution Boiler is not working for central heating or hot water L L L Is there power to the boiler i.e. is the left hand side green LED (A) alight and flashing every 4 seconds. If not this is not a boiler fault --contac t the installer Check pressure gauge on boiler shows a minimum of 1 bar. If not re---pressurise via the filling loop to 1 bar (if unsure contact your installer), turn off the tap on the filling loop and press the reset button (D) to reset the boiler. If unable to do so or if the pressure continues to drop after filling then contact your installer Is the lockout signal lamp (E) alight ---Press boiler reset button (D) --I f boiler still does not fire contact the installer Boiler goes through ignition sequence but will not fire for either central heating or hot water and then goes to ignition lockout L Check gas supply (try another gas appliance cooker/fire etc) If no gas supply then this is not a boiler fault --Contac t the gas supplier Fan & pump run continuosly but there isno attemptatignition L Check that the air pressure switch test caps, on top of the boiler, are fitted correctly. Operating for hot water but will notoperate for central heating L L L L Check that integral programmer is set to an .ona period and the function switch is set to .auto.---If it still does not operate contact your installer If fitted with an external programmer check that the central heating channel is set at an .ona period --I f it still does not operate contact your installer Check the room thermostat is set at the required temperature ---Test the room thermostat by turning fully up --I f this does not respond contact your installer Check the radiator temperature control (C) is set at the winter setting for central heating The nature of all combination boilers is to heat up water directly from the incoming mains water supply directly through the boiler to supply domestic hot water at the stated flow rates, (as shown in the boiler installation instructions), to achieve a 35uC temperature rise. As the ambient temperature of the cold main varies during the summer and winter months it is likely in the colder winter months that the flow rate will need to be reduced at the outlet taps to achieve the same temperatures achieved in the warmer summer months. This is not a fault with the appliance but is relevant to the varying temperature of the incoming cold mains water supply. Ideal Consumer Helpline: 01482 498660 Caradon Ideal limited pursues a policy of continuing improvement in the design and performance of its products. The right is therefore reserved to vary specification without notice. Ideal Boilers, P.O. Box 103, National Ave, Kingston Upon Hull, HU5 4JN. Tel. 01482 492251 Fax. 01482 448858. Registration ...

Ce manuel est également adapté pour les modèles :
Chauffe-eau - MINI HE C28 (187.56 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories