Log:
Évaluations - 5, GPA: 4 ( )

Instructions Empire Comfort Systems, Modèle DVP48FP3

Fabricant : Empire Comfort Systems
Taille : 4.54 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


When the internal beads of each starting outer pipe line up, rotate pipe section clockwise 90° (approximately 3 inches). The vent pipe is now locked together. Continue replacing components per the vent system configuration. Be certain that each succeeding vent component is securely fitted and locked into the preceding component in the vent system. Reassembly and Resealing Gas Accumulation Relief System Glass Frame Assembly and Combustion Chamber Whenever the glass frame assembly is pivoted open by a delayed ignition in the main burner, the glass frame assembly gaskets and combustionchambermustbeexaminedbyaqualifiedserviceperson for damage. All damaged gaskets on the glass frame assembly and combustion chamber must be replaced by a qualified service person. If damage occurs to the combustion chamber, it must be replaced by a qualified service person. Contact Empire Comfort Systems, Inc. for replacement parts. Vertical Through the Roof Applications (Figure 45) Your Gas Fireplace has been approved for: a) Vertical installations up to 40 feet in height. b) Two sets of 45 degree elbow offsets within these vertical installations. From 0 to a maximum of 8 ft. a vent pipe can be used between elbows. c) Wall straps must be used to support offset pipe every 4'. This application will require that you first determine the roof pitch and use the appropriate venting components. 4012.19 Figure 45 17375-6-0705 Page 27 Page 28 17375-6-0705 WARNING: Failure to position the parts in accordance with this diagram or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. Attention: Do not use Figure 48B or Figure 49 to order logs. Refer to parts view on page 45 and parts list on page 46 to order logs and/or ember material for your appropriate fireplace model. LOG PLACEMENT (3 LOG SET) Before you begin: If you are installing logs into the DVP42 or DVP48 model then this fireplace is supplied with a set of three ceramic fiber logs. Do not handle these logs with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers. After handling logs, wash your hands gently with soap and water to remove any traces of fiber. The positioning of logs is critical to safe and clean operation of this fireplace. Sooting and other problems may result if the logs are not properly and firmly positioned in the fireplace. Please refer to Figure 48A, Figure 48B, and Figure 49 and corresponding WARNING, when completing the following log placement steps. 1. Remove top louver, grasp louver, lift and pull forward. 2. Lower bottom louver, lift and hinge forward. 3. Release two glass frame spring clamps at bottom of firebox 4. Place bottom log onto main burner. Align holes on bottom log with (4) locator pins on burner. 5. Place rear log on rear log shelf. Place rear log so that the locator holes align with the (2) locator tabs in the log support shelf. 6. Place top branch onto flat area of rear log and over the front of the bottom log. 7. Place decorative rock in front of grates and sides of main burner. ATTENTION: Do not place decorative rock on logs or on burner. The decorative rock should only be placed on the fireplace floor. 8. After all logs are properly positioned, place small "dime" size pieces of Rockwool lightly across the front round "blueflame" ports. Place the ember material (Rockwool pieces) side by side. Do not stack more than one layer of embers across the burner ports. See Figure 48A. 9. Replace glass door onto firebox. 10. Secure the two glass frame spring clamps at bottom of firebox. 11. Align the tabs on top louver brackets with slots in front posts to secure top louver. 12. Close bottom louver. Lift slightly to engage the end tabs into the slots in fireplace sides to close louver panel. TOP BRANCH REAR LOG BOTTOM LOG Figure 48B Figure 48A EMBER PLACEMENT REAR LOG LOCATOR TABS BOTTOM LOG LOCATOR PINS Figure 49 17375-6-0705 Page 29 The OWNER should carefully read and follow these operating instructions at all times. Lower the door assembly to view the gas controls for the fireplace. Initial Lighting Upon completing the gas line or turning the gas valve on after it has been in the “OFF” position, a small amount of air will be in the lines. When first lighting the fireplace, it will take a few minutes for the lines to purge themselves of this air. Once the purging is complete, the fireplace will light and operate satisfactorily. Subsequent lightings of the appliance will not require such purging if the gas valve is not turned to “OFF.” Pilot Flame (Figure 51) The thermopile/thermocouple (standing pilot) tips should be covered with flame. Figure 51 750 Millivolt System The standing pilot (750 millivolt system) is a continuous burning pilot. The pilot remains ON even when the main burner is OFF. When you ignite the pilot, the thermocouple produces millivolts (electrical current) which energizes the magnet in the gas valve. After 30 seconds to 1 minute time perio...

Ce manuel est également adapté pour les modèles :
Chauffe-eau - DVP42FP3 (4.54 mb)
Chauffe-eau - DVP42FP9 (4.54 mb)
Chauffe-eau - DVP42FP7 (4.54 mb)
Chauffe-eau - DVP48FP7 (4.54 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories