|
Facilité d'utilisation
Wall Switch, FWS-1 Connect the green and red, stripped and bare, wires on the REMOTE/OFF/ON switch wire harness to the wall switch. Turn the REMOTE/OFF/ON switch to the REMOTE position. Pivot the rocker switch on the FWS-1 to the ON position. Wall Thermostats (optional) TRW - Wireless for Millivolt models TMV - Reed switch for Millivolt models Battery Operated Remote Controls, FRBC, FBRTC, and TRW Connect the green and red, stripped and bare, wires on the REMOTE/OFF/ON switch wire harness to the remote receiver that is a component in the remote kit. Turn the REMOTE/OFF/ON switch to the REMOTE position. Follow instructions included with the remote to complete installation. Note: If batteries fail in the remote, and immediate heat is desired, turn the REMOTE/OFF/ON switch from the REMOTE position to the ON position. Electric (120 volt) Operated Remote Control, FREC Connect the green and red, stripped and bare, wires on the REMOTE/OFF/ON switch wire harness to the wires on remote receiver that is a component in the FREC. Turn the REMOTE/ OFF/ON switch to the REMOTE position. Follow instructions in the FREC to complete installation. NOTE: If electric (120 colt) fails in FREC, and immediate heat is desired, turn the REMOTE/OFF/ON switch from the REMOTE position to the ON position. Installation of Remote Receiver Place remote receiver on the floor of fireplace behind the louver as far forward as possible. Attention: The velcro loop and hook are not necessary in this installation but can be used to secure remote receiver. Refer to remote control installation and operating instructions for more details on remote control. Millivolt Control The valve regulator controls the burner pressure which should be checked at the pressure test point. Turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point (Use test point “A” closest to control knob). After taking pressure reading, be sure and turn captured screw clockwise firmly to re-seal. Do not over torque. Check for gas leaks. Millivolt thermopile is self generating. Gas valve does not require 24 volts or 110 volts. Check System Operation Millivolt system and all individual components may be checked with a millivolt meter 0-1000 MV range. It is important to use wire of a gauge proper for the length of the wire: Recommended Wire Gauges Maximum Length Wire Gauge 1' to 10' 18 10' to 25' 16 25' to 35' 14 Page 30 17375-6-0705 17375-6-0705 Page 31 STANDING PILOT WIRING DIAGRAM Figure 52 (OPTIONAL) THERMOSTAT (OPTIONAL) WALL SWITCH Page 32 17375-6-0705 STANDING PILOT LIGHTING INSTRUCTIONS 4. Push in gas control knob slightly and turn clockwise to "OFF." Do not force. 5. Close bottom louver assembly. 9. Push in control knob all the way and hold in. Repeatedly push the piezo ignitor button until the pilot is lit. Continue to hold the control knob in the for about one (1) minute after the pilot is lit. Release knob, and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 9. • If the control knob does not pop up when released, STOP and IMMEDIATELY call a qualified service technician or gas supplier. • If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier. 10. Turn gas control knob counterclockwise to "ON." 11. Close bottom louver assembly. 12. Turn on all electric power to the appliance (if applicable). 13. Set REMOTE/OFF/ON switch to desired setting. 1. Stop! Read the safety information above. 2. Set REMOTE/OFF/ON switch to OFF. 3. Turn off all electric power to the appliance (if applicable). 4. Lower bottom louver assembly. 5. Push in gas control knob slightly and turn clockwise to "OFF." Note: Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force. 6. Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you then smell gas, STOP! Follow "B" in the safety information above. If you do not smell gas, go to the next step. 7. Find pilot - Follow metal tube from gas control. The pilot is behind the burner on the right side. 8. Turn gas control knob counterclockwise to "PILOT." TO TURN OFF GAS TO FIREPLACE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. Before lighting smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. What To Do If You Smell Gas • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, cal...
Ce manuel est également adapté pour les modèles :Chauffe-eau - DVP42FP9 (4.54 mb)
Chauffe-eau - DVP42FP7 (4.54 mb)
Chauffe-eau - DVP48FP3 (4.54 mb)
Chauffe-eau - DVP48FP7 (4.54 mb)