Log:
Évaluations - 3, GPA: 4 ( )

Instructions Ariston, Modèle EURO COMBI 47-116-10

Fabricant : Ariston
Taille : 994.43 kb
Nom Fichier : 26ef2239-067b-4cd0-80de-f786b8180a24.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


47-116-10 / 47-116-12 Installation Instructions Type C Boilers LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER Country of destination: GB TABLE OF CONTENTS 1. GENERAL INFORMATION 1.1 General Instructions 1.2 Technical Information 1.3 Overall View 2. INSTALLATION 2.1 Reference Standards 2.2 Siting the Appliance 2.3 Overall Dimensions 2.4 Clearances 2.5 Mounting the Appliance 2.6 Electrical Connection 2.7 Gas Connection 2.8 Water Connections 2.9 Flue Connection 2.10 Room Thermostat Connection 2.11 Electrical/System Diagrams 2.12 Water Circuit Diagrams 3. COMMISSIONING 3.1 Initial Preparation 3.2 Removing the Front Panel 3.3 Control Panel 3.4 Initial Start-up 3.5 Operational Adjustments 3.6 Combustion Analysis 3.7 Fume Discharge Monitoring 3.8 Boiler Safety Systems 3.9 Draining the System 4. GAS ADJUSTMENTS Gas Adjustment Table 4.1 Changing the Type of Gas 5. MAINTENANCE 6. MISCELLANEOUS 6.1 Wiring Diagram for Two Heating Zones 6.2 Wiring Diagram for Connection to Ariston Unvented Cylinderl 2 B023 1. GENERAL INFORMATION This manual is an integral and essential part of the product. It should be kept with the appliance so that it can be consulted by the user and our authorised personnel. Please carefully read the instructions and notices about the unit contained in this manual, as they provide important information regarding the safe installation, use and maintenance of the product. For operating instructions please consult the separate User’s Manual. User’s Manual A/23 MFFI A/27 MFFI 1.1 General Instructions Read the instructions and recommendations in these Installation Instructions carefully to ensure proper installation, use and maintenance of the appliance. Keep this manual in a safe place. You may need it for your own reference while our Servicing Centre technicians or your installer may need to consult it in the future. This is a combined appliance for the production of central heating (C.H.) and domestic hot water (D.H.W.). This appliance must be used only for the purpose for which it is designed. The manufacturer declines all liability for damage caused by improper or negligent use. No asbestos or other hazardous materials have been used in the fabrication of this product. Before connecting the appliance, check that the information shown on the data plate and the table on pages 4-5 comply with the electric, water and gas mains of the property.You will find the data plate on the reverse of the control panel. The gas with which this appliance operates is also shown on the label at the bottom of the boiler. Do not install this appliance in a damp environment or close to equipment which spray water or other liquids. Do not place objects on the appliance. Do not allow children or inexperienced persons to use the appliance without supervision. If you smell gas in the room, do not turn on light switches, use the telephone or any other object which might cause sparks. Open doors and windows immediately to ventilate the room. Shut the gas mains tap (on the gas meter) or the valve of the gas cylinder and call your Gas Supplier immediately. If you are going away for a long period of time, remember to shut the mains gas tap or the gas cylinder valve. Always disconnect the appliance either by unplugging it from the mains or turning off the mains switch before cleaning the appliance or carrying out maintenance. In the case of faults or failure, switch off the appliance and turn off the gas tap. Do not tamper with the appliance. For repairs, call your local Authorised Servicing Centre and request the use of original spare parts. For in-guarantee repairs contact MTS (GB) Limited. Check the following at least once a year: 1 -Check the seal of water connections, replacing the gaskets if necessary. 2 -Check the seal of the gas connections, replacing the gaskets if necessary. 3 -Check the general condition of the appliance and of the combustion B023 3 chamber visually. 4 -Visual check of the combustion: clean burners if necessary. 5 -With reference to point 3, dismantle and clean the combustion chamber if necessary. 6 -With reference to point 4, dismantle and clean the injectors if necessary. 7 -Visual check of the primary heat exchanger: -check for overheating of the exchangers fins; -clean the exhaust side of the exchanger and fan if necessary. 8 -Regulate the gas pressure, ignition pressure, partial flame, maximum flame. 9 -Check proper operation of the heating safety system: -maximum safety temperature; -maximum safety pressure. 10 -Check the proper operation of the gas safety system: -gas or flame safety device; -gas valve safety device. 11 -Check that the electrical connections have been made in compliance with the instructions shown in the installation instructions. 12 -Check the efficiency of the hot water supply (flow and temperature). 13 -Check general operation of the appliance. 14 -Check the exhaust system for the combustion products. 1.2 Technical Information A/23 MFFI A/27 MFFI CE Certification Heat Input ...

Ce manuel est également adapté pour les modèles :
Chauffe-eau - EURO COMBI A/27 MFFI (994.43 kb)
Chauffe-eau - EURO COMBI 47-116-12 (994.43 kb)
Chauffe-eau - EURO COMBI A/23 MFFI (994.43 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories