Log:
Téléchargements : 46   Taille : 505 kb   Fabricant : Bryant  
Catégorie : Chauffe-eau
@name

317 240 5662 Installation Ins GAS-FIRED WATER OR STEAi'1 30ÎLER Cancels: 39234D23 NOTE: THESE INSTRUCTIONS MUST BE LEFT ON OR NEAR THE BOILER. The Model 234 is a low-pressure» sectional, cast-iron water and steam boiler. The design is certified by A.G.A. for use with natural, and propane gases. It is tested for a maximum working pressure of 100 psi on water and 15 psi on steam in accordance with ASME standards for cast-iron boilers. The boiler is available as a Type GW ■ Gravity, Type PW -

Téléchargements : 5   Taille : 503 kb   Fabricant : Bryant  
Catégorie : Chauffe-eau
@name

This air must be : supplied through two openings of equal area; 'one ¡located above draft diverter relief opening and .other near floor.. Total free area of each openiiig should be equal to 1 square inch for, each 1,0.00 Btuhof boiler input. There should be a minimum of 100 square inches ¡for each opening. If air openings are directly to outdoors, minimum free area should be 1 square inch per 2,000 Btu .per hour of input rating, or in accordance with ANSIZ21.30 or the latest edition of “American

Téléchargements : 0   Taille : 980 kb   Fabricant : Bryant  
Catégorie : Chauffe-eau
@name

The design is certified by' the American Gas Association for use with natural or propane gas. The typé S boiler can be used in steam systems with a maximum working pressure of 15 psig. The type W boiler can be used in water systems with a normal working pressure of 30 psig and is available for systems with working pressures of 50 psig or 100 psig when appropriate gauge and relief controls are used. All installations are subject to codes established by local utilities or other authorities having

Téléchargements : 0   Taille : 211 kb   Fabricant : Bryant  
Catégorie : Chauffe-eau
@name

Maximum water temperature is 190°F. The package consists of the hot water coil, four plenum angles, and four plenum adapter angles. For cooling only, an optional control assembly (P/N 59684D02) is available. It consists of a terminal block, a tranformer, an SPDT relay, and a box. When adding a hot water coil, a UL listed relay package is used to control the fan in the heating cycle. Valves, may be used to control water flow through the coils in multiple installations, if desired. NOTE: Hot wa

Téléchargements : 29   Taille : 337 kb   Fabricant : Bryant  
Catégorie : Chauffe-eau
@name

Filtrol Package (Up to 75,000 Btuh Input) KBAFP0101DNK Filtrol Package (Up to 150,000 Btuh Input) KBAFP0201DNK Filtrol Package (Over 150,000 Btuh Input) KBAFP0301DNK High Limit Control KBAHL0101DNK Combustible Floor Base (2 thru 6 section models) KBASB0301DNK Combustible Floor Base (7 thru 9 section models) KBASB0401DNK Zoning Valve 3/4 in. KBAZV0101DNK Zoning Valve 1 in. KBAZV0201DNK Gas Conversion Kit Natural to Propane (After 1799V) KBANP0201DNK Gas Conversion Kit Propane to Natural KBAPN0201

Téléchargements : 0   Taille : 337 kb   Fabricant : Bryant  
Catégorie : Chauffe-eau
@name

FACTORY INSTALLED FEATURES—A factory-installed drain is provided should the boiler ever need to be drained. Oil primary control prevents boiler in operation in the event of flame loss. SECTIONS TESTED—Each section is hydrostatically tested to 50 psig. Individual sections are tested to 125 psig at factory. Assembled sections are tested to 75 psig at the factory. The maximum allowable pressure is 50 psig for hot water boilers. EASE OF INSTALLATION—Circulator is shipped pre-wired with 6 ft bx condu

Téléchargements : 2   Taille : 337 kb   Fabricant : Bryant  
Catégorie : Chauffe-eau
@name

† 7–9 Section Models on BS1, BS2, BW1, and BW2; 6–7 Section Models on BW3. Note: Accessory High Limit Control is a strap-on aquastat used as an auxiliary limit or reverse acting circulator control. —3— CIRCULATOR CURVE WATER FLOW M3/H WATER FLOW GPM TOTAL HEAD METERS TOTAL HEAD FEET 1 40 2 4 6 8 10 12 8 12 16 20 24 2 3 4 5 3 2 1 WATER BOILER CIRCULATOR CURVE ELECTRICAL DATA ALL MODELS Voltage—Hertz—Phase 115 — 60 — 1 Minimum Branch Circuit Wire Size (AWG) 14 Maximum Fuse Size (Amps) 15 Control C

Téléchargements : 3   Taille : 337 kb   Fabricant : Bryant  
Catégorie : Chauffe-eau
@name

Assembled sections are tested to 75 psig at the factory. The maximum allowable pressure is 50 psig for hot water boilers. PROPANE CONVERTIBLE—With factory approved conversion kit accessory. WARRANTY—The aluminum sections are covered by a limited 15-year warranty on the entire assembly. Circulator pump is covered by a limited 3-year warranty. All other parts are covered by a 1-year limited warranty. SPECIFICATIONS UNIT SIZE 050 075 100 Sections 1 GAS CONTROLS Gas Valve Honeywell Inlet Size In. 1/

Téléchargements : 12   Taille : 337 kb   Fabricant : Bryant  
Catégorie : Chauffe-eau
@name

Maximum heat is produced at a lower level on the thermal-pin sections, leading to peak efficiency. TITANIUM COMPOSITE BURNERS—Provide quiet operation, corrosion resistance and improved combustion efficiency. Propane convertible – with accessory kit. CONTROLS—An automatic gas valve and continuous pilot or intermittent pilot provide quiet, dependable operation of the burners. Factory-installed safety components assure protection against overheating, pressure buildup, and low-water operation. INSUL

Téléchargements : 1   Taille : 337 kb   Fabricant : Bryant  
Catégorie : Chauffe-eau
@name

† A 4-in. vent damper is supplied. A 4-in. to 3-in. reducer is also furnished. —9— DIMENSIONS BW1 and BW2 MODELS 23 1.4 . 31 3.8 . 5 3.8 . 4 3.4. 1 1.4. SUPPLY 26 1.2 . 12 1.4. A 8. TEMPERATURE/ PRESSURE GAGE SPILL SWITCH DRAIN VALVE INT. PILOTROLLOUT SWITCH GAS 1 1.4. RETURN1 1.4. NPT AQUASTAT VENT DAMPERASME RELIEF VALVE CONTROL VALVE LEFT SIDE FRONT RIGHT SIDE DIMENSIONS (In.) CLEARANCES (In.) UNIT SIZE A VENT CONNECTION 037 8 3 070 11-1/4 5 105 14-1/2 6 140 17-3/4 6 175 21 7 210 24-1/4 7 245





catégories