Log:
Évaluations - 3, GPA: 3 ( )

Instructions Everpure, Modèle 625.34854

Fabricant : Everpure
Taille : 1.36 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Does the time display show the correct time of day? --If display is blank, check power source to the softener. --If time is flashing, power was off for over 24 hours. The softener resumes normal operation but regenerations occur at the wrong time. --If an error code (Example: Err3) shows in the face plate display, go to AUTOMATIC ELECTRONIC DIAGNOSTICS. ° Plumbing bypass valve(s) must be in Full Service position. 3. The inlet and outlet pipes must connect to the softener inlet and outlet respectively, ° Is the transformer plugged into a "live ", grounded wall outlet, and the power cable fastened securely? 5. The valve drain hose must be free of kinks and sharp bends, and not elevated over 8 ft, above the floor, SERVICE TECH. INFORMATION are needed, the service technician must have the assistance, call toll free, 1-800-426-9345. WIRING SCHEMATIC NC _'_POSITION SWITCH 0 NO Thll Kenmore _Teni_8 IIMMI b W_mr _ J REMOVE THE TOP COVER AND SALT TANK COVER 6. Is there salt in the storage tank? 7. Is the brine tubing connected? (See water flow diagrams). 8. Is the brine valve float set right? (See page 23). ° Press the #l SELECT button 2 times to display the hardness setting. Be sure it is the correct setting for the household _kwater supply. (Make a hardness test of the raw water and compare with the hardness setting. Also test a soft water sample to verify if a problem exists.) Press the #1 SELECT button twice more to return to present time in the display. If you do not find the problem after making initial checks, do the MANUAL INITIATED ELECTRONIC DIAGNOSTICS, and the MANUAL ADVANCE REGENERATION CHECK. _N SECTION 5 SERVICE TECH INFORMATION 5A. TROUBLESHOOTING AUTOMATIC ELECTRONIC DIAGNOSTICS The chart below shows the error codes that could The face plate computer has a self-diagnostic appear, and the possible defects for each code. function for the electrical system (except input power and water meter). The While an error code appears in the display, all face plate buttons are inoperable except the SELECT computer monitors the elec-_--_--Er r_ button. SELECT remains operational so the service tronic components and circuits ! person can make the MANUAL INITIATED for correct operation. If a malfunction occurs, an error f ELECTRONIC DIAGNOSTICS (below) to further isolate the defect, and check the water meter. code appears in the face plate ....... display. POSSIBLE DEFECT MOST LIKELY -_' _, LESS LIKELY CODE Err1 motor inop. / wiring harness or connection to switch / position switch / face plate Err2 face plate Err3 motor / face plate See face plate replacement on Err4 face plate / position switch page 22. Err5 face plate PROCEDURE FOR REMOVING ERROR CODE FROM FACE PLATE: 1. Unplug transformer 2. Correct defect 3. Plug in transformer 4. Wait for 6 minutes. The error code will return if the defect was not corrected. MANUAL INITIATED ELECTRONICS DIAG-valve positionimdicator (Fdland Brine flashing) NOSTICS • minutes of bnning bme u_.. / iI-lrl-_-(begirmtocountdown I UU when valve reaches lo To enter diagnostics ° the ii UU brJrtirl_ po_i_on) VALVE TO POSITION --from a error code display, press #1 _, "_ U_ ROTATING .... _-_--" _'_'_ wa_r meter ANOTHER(FROM SELECT button. turbinecount FILLTO BRINING IN posilionswitchindicator THIS EXAMPLE) --from a time display, press and hold the #1 (dosed) SELECT button for 3 seconds. All of the preceeding displays show what position You will see 1 of the following displays. the valve is in, if the turbine is operating, and the valve position indicator position switch open or closed status. _r mLi_ numberol days VALVE IN SERVICE o Press the ON/OFF-HOLD button to advance POSITION the valve to the next position. To verify _ water meter il-V =_1_ " regenera*_on component operation, or to possibly isolate a ....... turbine count defect, observe the following. \ _ition switch indicator POSITION SWITCH STATUS: With the valve in (open) service, or any of the recharge cycles, the switch indicator will show open -'_-. While the valve is valve poytion indicator rotating from 1 position to another, the indicator _,_ _./n_._n 1_ rninutesoffill will show the switch closed -_-. A defect is I ---i:---I LI=I'L U -_ cycleremaining VALVE IN A RECHARGE probable if indications vary from this pattern. m _ POSITION (FILL, IN THIS BBIt ==, * water mete{ EXAMPLE) turt_ne count position switch indicator (open) SECTION 5 SERVICE TECH. INFORMATION 5A. TROUBLESHOOTING WATER METER TURBINE: With soft water in use, the turbine flow rate display continually repeats a 000 to 199 count for each gallon of water passing through the turbine. The display will remain a steady • 000 if soft water is not in use (open a nearby soft water faucet to check). If you don_ get a reading in the display, with facuet open, pull the sensor from the valve outlet port. Pass a small magnet back and forth in front of the sensor. You should get a reading in the display. If you get a reading, unhook the in and out plumbing and check the turbi...

Ce manuel est également adapté pour les modèles :
purificateurs d'eau - 625.34854 (1.36 mb)
purificateurs d'eau - 625.34854 (1.36 mb)
purificateurs d'eau - 625.34855 (1.36 mb)
purificateurs d'eau - 625.34854 (1.36 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories