It can not be used in overseas where the power rate is different. For the right operation of Coway Water Filtration System read this manual. Water Filtration System The Letter of Guarantee is enclosed here with this Coway product realizing "Quality is the best policy". P-07FR/RV/U/UV 2 3 4 5 02 The electric filter change indicator reminds user when to change the filter. If the system is in use for an extended period of time, the filter can be protected by the auto flushing feature. Coway invente
•This reverse osmosis system contains a replacement treatment component critical for the effective reduction of total dissolved solids, and that the product water shall be tested periodically to verify that the system is performing properly. 22 23 FILTER REPLACEMENT METHOD Installation and Cleaning Filter Replacement Method . Please replace filter Filter replacement time is indicated when the corresponding LED of filter flickers in window display. Each of A, B and C respectively represents Neo-s
After repeating for four cycles, this device will auto flush and then shut off. (Only P-07FR/RV) 3 If the system does not work when the faucet is opened, push the restart button for one seconds to restart extraction. (Only P-07FR/RV) 4 .. / The influent water should not include any organic solvents because they may damage RO membrane polymer and may decrease the performance of RO membrane. .The“ Water Shortage Indicator”lights up when a UV Lamp filter replacement is needed. Change the filter whe
(Based on the tap water) Therefore, the filter change cycle may be reduced for the area with poor water quality or more applications. Filter Replacement Cycle Filter Replacement Method 2. Please separate the top cover and the front cover. (After blocking the main water extraction hole using the faucet stopper in the top of the inner water tank and loosing a screw with a driver, separate it.) . . . 1. After pulling the power cord necessarily (P-07QR only), close the main water supply valve and dr
........................................................ .................................. ................................ .................... ................................................ ...................... ...................... ........................................................ .................................. ................................ .................... ................................................ ...................... ...................... ..................
Clean after unplugging, and don’t clean by spraying the water directly or don’t wipe the product using the benzene and thinner. Otherwise, electric shock or fire may occur as a result. Do not move the product by pulling the power cord. (P-07QR only) Otherwise, electric shock or fire may occur as a result. 3 3 SAFETY INFORMATION Warning: If not observed, serious physical injury or property damage may occur as a result. Caution: If not observed, minor physical injury or property damage may occur a
When the lamp on the indication parts are turned out When the lamp on the indication parts are turned out please check the reason for break of electric supply in case of electricity failure or other conditions. ¦ Regular filter change The regular filter change is very important to have clean water. The filter after life is ended may degrade the performance. Thus, do not miss the time for the filter change. ¦ Check the Lamps!! When not using for a long time please lock the main water supply valve
Is room water overflowing or leaking? Is the power turned on? Is the water being supplied properly? Is the water inlet hose too long? Is the hose bent? Is the water supply valve closed, or the water supply cut? Is it about time to change the filter? Request filter change. Open the water supply valve. Straighten the hose. Shorten the water inlet hose to 5m or less. Check the water supply valve. Connect the power to the voltage rating that matches it on the rating plate. Request A/S. / . Please re
Fire may occur as a result. Close the main water supply valve and unplug the power cord when not using for a long time. Electrical shock or fire may occur as a result. Do not attempt to repair the power cord. Electrical shock or fire may occur as a result. Unplug the unit before repair, inspection, or replacement. Electrical shock may occur as a result. Do not run the power cord under a heavy object to prevent it from being damaged. Electrical shock or fire may occur as a result. If the cord or
The components of our water filtration system are as followed: WARNING NEO-SENSE FILTER Reduces various foreign bodies that come from the feed water pipe such as dirt, sand, rust particles, VOCs and chlorine. MEMBRANE FILTER(RO) FINE POST-CARBON FILTER The RO(Reverse Osmosis) Membrane filter reduces Pentavalent Arsenic, Barium, Cadmium, Mercury, Selenium, Radium 226/228, Trivalent chromium, Hexavalent chromium, Lead, Nitrate/Nitrite. The influent water to the system shall include the following c