Log:
Évaluations - 2, GPA: 3.5 ( )

Instructions Perlick, Modèle 66134-1

Fabricant : Perlick
Taille : 1.68 mb
Nom Fichier : Z2149A-10.11.06.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Z2149A Rev. 10.11.06 4 5 Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice. Diagram #2 – Beer Pump Form No. Z2149A Rev. 10.11.06 6 Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice. Diagram #3 – Cleaning Diagram Form No. Z2149A Rev. 10.11.06 Cleaning Instructions General Information ¦ The cleaning of beer lines with the new integral flow reversal feature incorporated into the Perlick Beer Pump gives the line cleaner numerous configurations for line cleaning. Although the Perlick Beer Pump can be used as an in-line pump for moving the solution from the coupler to the faucet due to its capability of working with negative lift, the following is the recommended method for cleaning beer lines with the Perlick Beer Pump with integral flow reversal installed. Cleaning Beer Lines using Smart Couplers ¦ Disconnect Smart Coupler from beer connector lines and soak Smart Couplers in cleaning solution. ¦ Couple the two beer connectors together using Perlick’s double male adapter part # 186 with beer washers. ¦ Determine which sets of lines will be cleaned together and rotate the Dispense/Reverse Flow handle to the Reverse Flow position on the line which fluid will be circulated from the faucet, to the tap. ¦ Remove the faucet from the line to which the Beer Line Cleaner pump will be connected. Soak faucets and brush clean before reinstalling. ¦ Connect Beer Line Cleaner pump to the shank. ¦ Follow standard beer line cleaning procedures. Perlick recommends that the lines first be flushed with clean warm water (Water temperature not to exceed 100 degrees). Mix line-cleaning solution per manufactureris directions. Circulate the solution thoroughly (Time for circulation dependent on length of the system and pump capabilities). Rinse the lines using clean cold water (Ensure all line cleaning solution has been removed from the lines to prevent hazardous results). ¦ Disconnect line-cleaning pump and reinstall beer faucets. ¦ Reconnect couplers to beer connector lines and return Beer Pump Dispense/ Reverse Flow valve to the dispense position. ¦ Reconnect couplers to keg and open dispensing head faucets until clear beer flows. ¦ When a beer system with beer pumps will be shut down for an extended period, clean the system thoroughly. After completing the rinsing step, prepare a mixture of 50% food grade Glycerine and 50% water. Load the lines with this mixture and make sure both ends of the system are closed. Glycerine/water mixture should remain in the lines for the duration of the shutdown period. Replacement Parts 44................... Air valve 40115............. Regulator body 40129............. Regulator body 43553A .......... Regulator repair kit 63706............. Flow reversal valve 63707............. Elbow, flow reversal, 2/bag 63708............. Fitting, tee, gas, barbed 1/4” with check valve 63709 .............

Ce manuel est également adapté pour les modèles :
Dispensers - 66134-2 (1.68 mb)
Dispensers - 66134-3 (1.68 mb)
Dispensers - 66134-4 (1.68 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories