Log:
Évaluations - 1, GPA: 4 ( )

Instructions Perlick, Modèle 66134-2

Fabricant : Perlick
Taille : 1.68 mb
Nom Fichier : Z2149A-10.11.06.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


¦ Cut a piece of CO2 tubing (red 9/16” vinyl tubing) and push one end onto barbed CO2 outlet to Keg Couplers (See diagram on page3). Position clamp over joint and tighten. Push the other end over the barbed gas inlet on the Perlick Smart Coupler. Position clamp over joint and tighten. Important Notes . CAUTION: If using CO2 as a pressure supply for pumps, pump exhaust must be vented to a well ventilated area to avoid possible asphyxiation. . Never use a single keg to supply more than one beer pump. Using a single keg to supply more than one pump will create flow problems, pump burn out or premature Smart Coupler shut-off. . Pump panels should never be installed more than 5 (five) feet above the cooler floor. A height in excess of 5 (five) feet causes additional pressure drop between the keg and pump inlet which may cause degassing or premature Smart Coupler shut-off. . Beer pumps must be used in combination with an empty keg sensing device. If an empty keg sensing device is not used premature pump failure will occur. . If using compressed air as pressure source to drive pumps, pump and keg regulators need to be seperated. Air must be clean and dry. Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice. Form No. Z2149A Rev. 10.11.06 2 3 Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice. Diagram – Beer Pump Panel Diagram Form No. Z2149A Rev. 10.11.06 How to Operate – Beer Pump Panels ¦ Adjust primary CO2 regulator by turning adjusting screw counterclockwise until it turns freely, then turn hand valve counterclockwise on CO2 cylinder to the fully open position. Next, turn regulator adjusting screw clockwise until required system pressure plus an additional 15 psig is reached. Note: If CO2 is only being used for keg- applied pressure, adjust to approximately 40 psig. Note: If using air to drive beer pumps, adjust the air compressor output regulator pressure to a minimum of 15 psig. greater than the maximum required system pressure required to operate the beer pumps. maximum setting 100 psig. ¦ Adjust secondary CO2 regulator which supplies the keg pressure located on the beer pump panel to the proper pressure setting. Setting depends on beer brand and temperature. Desired goal is to maintain the natural carbonation in the beer. Open the shutoff valves. ¦ Ensure the Probe Valve on the Perlick Smart Coupler is in closed position. See figure 1. Ensure the Beer Pump Flow Reversal/Dispense handle is in the dispense position. Adjust the Secondary Air/ CO2 regulator located on the beer pump panel to a minimum operating pressure of 10 psig. Smart Coupler Probe Valve Lever Positions ¦ Connect the coupler to a regulated water supply with pressure less than 30 psig. Note: Pump damage may occur with pressure higher than 30 psig. ¦ Open the water supply. Then open probe valve on Perlick Smart coupler to the 45° positio...

Ce manuel est également adapté pour les modèles :
Dispensers - 66134-1 (1.68 mb)
Dispensers - 66134-3 (1.68 mb)
Dispensers - 66134-4 (1.68 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories