Fabricant : Cadet
Taille : 1.73 mb
Nom Fichier : 66b56e36-fc59-c814-09d0-ef3591a23095.pdf
|
Facilité d'utilisation
The casting top nests into the casting. 18. Insert center grill, left grill and right grill into casting top. 19. Level appliance by adjusting leveling bolts. 20. Assembly of stove casting is completed. OPTIONAL STONE INLAY INSTALLATION Whenever the standard grill top is replaced with a stone inlay you must install the top shield and heat shield, which are provided with the stone inlay. Installation of Optional Stone Inlay 1. Remove left grill, center grill and right grill from casting top. 2. Remove casting top from outer casting. 3. Placethecastingtoponanon-abrasivesurfaceinordertoprotect the porcelain finish. The exterior of the casting top should be facing the non-abrasive surface. 4. Attach 11 5/8" x 11 5/8" top shield to the interior of the casting top with (1) 3/8" bolt provided in hardware package. 5. Locate the (4) screw holes on the heat exchanger top. The screw holes are 8 3/4" apart. Position the angled front edge on the 12" x 19 3/8" heat shield with the front of the firebox. Align the (4) tabs with clearance holes on the 12" x 19 3/8" heat shield with the (4) screw holes on the heat exchanger top. Attach the 12" x 19 3/8" heat shield to the heat exchanger top with (4) 1/2" hex-head screws provided in hardware package. 6. Place the casting top onto the casting. The casting top nests into the casting. 7. Insert center stone inlay, left stone inlay and right stone inlay into casting top. 8. Installation of stone inlay is completed. Parts List Part Description Part Number Quantity Supplied 11 5/8" x 11 5/8" Top Shield CI-091 1 12" x 19 3/8" Heat Shield CI-092 1 3/8" Bolt R-3646 1 1/2" Hex-Head Screw R-2737 4 WIRE CHANNEL INSTALLATION The ON/OFF/REMOTE switch with harness is factory installed into the switch box. After the firebox is installed into the casting the wire channel can be installed. 1. Attach switch box on the left side of rear cover with (2) 10 x 1/2" screws. 2. Route wires from ON/OFF/REMOTE switch within wire channel. 3. Attach wire channel on the left side of the rear cover with (4) 10 x 1/2" screws. 4. Attach the black and green (wires) female push-ons to the TH/TPand TH (two outside male tabs) terminals on gas valve. Figure 12 16938-3-0806 Page 13 Page 14 16938-3-0806 Before operating this heater, please review the safety warnings pages at the beginning of this manual and those precautions and warnings listed below. 1. Know what type of ignition system this model has (standing pilot) and follow the applicable SAFETY and LIGHTING instructions. 2. Check to ensure there are no gas leaks. If you are unsure, turn gas off to the heater and call a service person or your gas utility. CAUTION: Clothing or other flammable material should not be placed on or near the appliance. WARNING: Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. 3. Tampering is DANGEROUS and voids all warranties. Any component that is found to be faulty, must be replaced with an approved component. Initial Lighting (Figure 14) Upon completing the gas line or turning the gas valve "ON" after it has been in the "OFF" position, a small amount of air will be in the lines. When first lighting the appliance, it will take a few minutes for the lines to purge themselves of this air. Once the purging is complete, the appliance will light and operate satisfactorily. Subsequent lightings of the appliance will not require such purging if the gas valve is not turned to "OFF." Standing Pilot Operation 1. Follow the SAFETY and LIGHTING INSTRUCTIONS for standing pilot controls found in this manual and on labels found attached to the appliance. CAUTION: During the initial purging and subsequent lightings, never allow the gas valve control knob to remain depressed in the "pilot" position without pushing the piezo ignitor button at least once every second. 2. D u r i n g t h e heating season, leave the control valve knob in the "ON" position. This will allow the pilot flame to remain lit. Turn the burner flame on or off with the appliance ON/OFF rocker switch, wall switch, remote control kits or 750 millivolt wall thermostat. NOTE: The gas control valve allows you to increase or decrease the height of the main burner flame. The control valve has a pressure regulator with a knob as shown in Figure 14. Rotate the knob clockwise to "HI" to increase the flame height and counterclockwise to "LO" to decrease the flame height. 3. When the heating season is over, turn the on/off switch to "OFF" and the control valve to "OFF". The system, including the pilot light, will be shut down. Maximum and Minimum Input The gas valve on the appliance allows the input to adjust between a maximum input of 30,000 to a minimum input of 21,000 Btuh. Please be advised, the maximum input provides the greatest amount of yellow flame and ember glow on the log set. The minimum input sub...
Ce manuel est également adapté pour les modèles :électrique - CIVF-25-21 (1.73 mb)