Log:
Évaluations - 4, GPA: 3.5 ( )

Instructions EMI, Modèle T4HB

Fabricant : EMI
Taille : 4.96 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Turn oFF PoWer SuPPlY FirST. Outdoor units may be cleaned or waxed if desired. Use a non-abrasive car wax. Panels should remain on the unit at all times. Service should be performed by a QUAli- FiED service agency only. All EMI products are subject to ongoing development programs so design and specifications may change without notice. Please consult the factory for more information. general reCommendaTionS Do not charge the straight cool units on cold days unless weighing in the charge. The heat pump systems may be charged in heat cycle between 35 and 75°F. These units use a heat cycle TXV and cannot be charged to superheat; use weight or subcooling method only. Charging should be done with a dial-acharge or weighed in with a scale. NOTE: For more information, please visit our web-site at or call 1-800-228-9364. 22multi-zone Heat Pump Condensing units S2HB dIMEnSIonS And SPEcIfIcAtIonS S2HB dIMEnSIonS And SPEcIfIcAtIonS noTe: All EMI products are subject to ongoing development programs so design and specifications may change without notice. 44” 38” 15” Electrical connections Front of unit Easy access interconnects on back of unit 1/2” Diameter Lag Holes 7” 7” 23.94” 12.44” 3.00” S2HB eleCTriCal SPeCiFiCaTionS model (1) VolTS/HZ/PHaSe Fan ComPreSSor 1 ComPreSSor 2 ToTal amPS min. Cir. amPS (2) HaCr BrKr rla HP rla lra rla lra 9900 208-230/60/1 1.8 0.33 3.4 23 3.4 23 8.6 9.5 15 2200 208-230/60/1 1.8 0.33 4.3 27 4.3 27 10.4 11.5 15 9200 208-230/60/1 1.8 0.33 3.4 23 4.3 27 9.5 10.6 15 (1) Circuit Designators: 9 = 9,000 Btuh • 2 = 12,000 Btuh (ex. - Model 9200 consists of one 9,000 Btuh compressor and one 12,000 Btuh compressor) (2) Always refer to the rating plate for Minimum Circuit Ampacity on all multiple compressor units. 23multi-zone Heat Pump Condensing units S2HB PiPing SPeCiFiCaTionS Sound daTa SHiPPing WeigHT model# line Sizes liquid Suction dBa lbs. 9900 1/4” 1/2” 64 159 2200 1/4” 1/2” 65 197 9200 1/4” 1/2” 65 187 S2HB SyStEM PErforMAncE S2HB SyStEM PErforMAncE S2HB wLH S2HB / WlH SYSTem PerFormanCe model Cooling HeaTing S2HB (Outdoor) indoor units Btuh Seer SHr eer Btuh HSPF C.o.P. 9900 WLH09 + WLH09 18,600 13.0 .80 11.9 14,800 7.7 3.3 2200 WLH12 + WLH12 22,600 13.0 .72 11.7 18,400 7.7 3.3 9200 WLH09 + WLH12 20,600 13.0 .76 11.7 16,600 7.7 3.3 CAH S2HB CAH S2HB / CaH SYSTem PerFormanCe model Cooling HeaTing S2HB (Outdoor) indoor units Btuh Seer SHr eer Btuh HSPF C.o.P. 9900 CAH12 + CAH12 18,600 13.0 79 11.4 14,600 7.7 3.1 2200 CAH12 + CAH12 22,600 13.0 .75 11.3 18,400 7.7 3.2 9200 CAH12 + CAH12 20,600 13.0 .77 11.3 16,500 7.7 3.1 24multi-zone Heat Pump Condensing units S2HB SyStEM PErforMAncE S2HB SyStEM PErforMAncE S2HB Side Discharge UNH S2HB / unH Side diSCHarge model Cooling HeaTing S2HB (Outdoor) indoor units Btuh Seer SHr eer Btuh HSPF C.o.P. 9900 UNH09 + UNH09 18,600 13.0 .75 11.9 14,800 7.7 3.3 2200 UNH12 + UNH12 22,600 13.0 .73 11.7 18,400 7.7 3.3 9200 UNH09 + UNH12 20,600 13.0 .74 11.7 16,600 7.7 3.3 25multi-zone Heat Pump Condensing units t2HB, t3HB, And t4HB dIMEnSIonS And SPEcIfIcAtIonS noTe: All EMI products are subject to ongoing development programs so design and specifications may change without notice. lInE SEt, Sound & WEIgHt dAtA model line Set diameters Sound Weight liquid Suction dBa lbs. T2HB8800 3/8” 5/8” 70 325 T2HB8400 3/8” 5/8” & 3/4” 70 325 T2HB4400 3/8” 3/4” 70 325 T2HB2400 1/4” & 3/8” 1/2” & 3/4” 70 325 T2HB9800 1/4” & 3/8” 1/2” & 5/8” 70 325 T3HB9990 1/4” 1/2” 70 325 T3HB9920 1/4” 1/2” 70 325 T3HB9980 1/4” & 3/8” 1/2” & 5/8” 70 325 T3HB9940 1/4” & 3/8” 1/2” & 3/4” 70 325 T3HB9220 1/4” 1/2” 70 325 T3HB9280 1/4” & 3/8” 1/2” & 5/8” 70 325 T3HB9240 1/4” & 3/8” 1/2” & 3/4” 70 325 T3HB2280 1/4” & 3/8” 1/2” & 5/8” 70 325 T3HB2240 1/4” & 3/8” 1/2” & 3/4” 70 325 T3HB2220 1/4” 1/2” 70 325 T4HB9999 1/4” 1/2” 70 325 T4HB9992 1/4” 1/2” 70 325 T4HB9922 1/4” 1/2” 70 325 T4HB9222 1/4” 1/2” 70 325 T4HB2222 1/4” 1/2” 70 325 26multi-zone Heat Pump Condensing units t2HB, t3HB, And t4HB SPEcIfIcAtIonS t2HB, t3HB, And t4HB SPEcIfIcAtIonS noTe: All EMI products are subject to ongoing development programs so design and specifications may change without notice. inTerConneCTing TuBing SPeCST2HB, T3HB, & T4HB models: Nominal Circuit Capacity Maximum Length Maximum Lift Liquid Line OD Suction Line OD 9,000 100’ 35’ 1/4” 1/2” 12,000 100’ 35’ 1/4” 1/2” 18,000 100’ 35’ 3/8” 5/8”* 24,000 100’ 35’ 3/8” 3/4” * CAH24, UNH24, WLH24 Suction Connection size is 3/4” O.D. and must bush down to 5/8” for 18,000 Btuh circuits at the indoor unit. ELECTRICAL SPECIFICATIONS • t2HB, t3HB, And t4HB 208/230V 60 HErtz 1 PHASE CAPACITY FAN MTR COMPRESSOR TOTAL AMPS MCA HACR BRKR MIN VOLT AMPS HP CIRCUIT #1 CIRCUIT #2 CIRCUIT #3 CIRCUIT #4 RLA LRA RLA LRA RLA LRA RLA LRA T2HB 8800 1.8 0.33 5.4 36 5.4 36 – – – – 12.6 14.0 15 197 8400 1.8 0.33 5.4 36 8.8 54 – – – – 16.0 18.2 25 197 4400 1.8 0.33 8.8...

Ce manuel est également adapté pour les modèles :
matériel de pompage - S2HB (4.96 mb)
matériel de pompage - T2HB (4.96 mb)
matériel de pompage - T3HB (4.96 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories